# Civil Technology Grade 12 Eastern Cape Mock 2019 Memo (Eng)

> Grade 12 Civil Technology memorandum from the Eastern Cape Mock Exam 2019 (English), 12 pages. Read online or download the free PDF.

- Page: https://www.hlayiso.com/library/civil-tech-gr12-memo-eng-sept2019-civil-services-docx/4081d050-e028-423c-803a-e634bcae6ed9
- Updated: 2026-09-27
- Subject: Civil Technology
- Grade: Grade 12
- Document type: Memorandum
- Year: 2019
- Exam period: Eastern Cape Mock Exam
- Curriculum: CAPS
- Pages: 12

Breadcrumbs: [Home](https://www.hlayiso.com/) › [Library](https://www.hlayiso.com/library) › [Grade 12](https://www.hlayiso.com/library/grade-12) › [Civil Technology](https://www.hlayiso.com/library/grade-12/civil-technology) › [Civil Technology Grade 12 Eastern Cape Mock 2019 Memo (Eng)](https://www.hlayiso.com/library/civil-tech-gr12-memo-eng-sept2019-civil-services-docx/4081d050-e028-423c-803a-e634bcae6ed9)

## About this document

Civil Technology · Grade 12 · Eastern Cape Mock Exam · 2019. Memorandum, 12 pages. Read online or download the PDF.

Read it free online on the page above; download the PDF from there.

## Document text

Text extracted from the PDF. Layout, diagrams and tables may not survive extraction.

### Page 1

Downloaded from hlayiso.com

                          NATIONAL
                     SENIOR CERTIFICATE

                             GRADE 12

                      SEPTEMBER 2019

         CIVIL TECHNOLOGY: CIVIL SERVICES
                 MARKING GUIDELINE

MARKS:   200

                  This marking guideline consists of 12 pages.

### Page 2

Downloaded from hlayiso.com
2                            CIVIL TECHNOLOGY: CIVIL SERVICES                   (EC/SEPTEMBER 2019)

QUESTION 1: SAFETY, OHSA AND MATERIALS (GENERIC)

1.1    3m                                                                                       (1)

1.2    (1) By means of a chute or (2) conveyor belt                                             (2)

1.3    Similar answer:
       (1) Prevents unauthorised entry and (2) to protect the public                            (2)

1.4    1.4.1   30°
               50°                                                                              (2)

       1.4.2   760 x 560 mm
               3,7 m                                                                            (2)

1.5    1 : 4 = 2 m = 0,5 m     (one meter horizontal to four metres vertical)
               4                                                                                (2)

1.6    (1) Not further than 2/3 (2) of the extension length                                     (2)

1.7    (1) The coating of a metal by means of electrolysis (2) with a thin layer of
       another metal                                                                            (2)

1.8    Any THREE advantages of electroplating metals:
       • Protects against corrosion
       • Improves the engineering and mechanical properties of metal
       • Increases the thickness of metal
       • Resistant against wear and tear                                             (3 x 1)    (3)

1.9    Any TWO advantages of galvanising metals:
       • Adds strength to the metal
       • Increases the thickness of metal
       • Prevents staining
       • Protects against corrosion                                                  (2 x 1)    (2)
                                                                                               [20]

Copyright reserved                                                                 Please turn over

### Page 3

Downloaded from hlayiso.com
(EC/SEPTEMBER 2019)             CIVIL TECHNOLOGY: CIVIL SERVICES                             3

QUESTION 2: GRAPHICS, JOINING AND EQUIPMENT (GENERIC)

2.1 2.1.1       False                                                                       (1)
    2.1.2       True                                                                        (1)
    2.1.3       True                                                                        (1)
    2.1.4       True                                                                        (1)
    2.1.5       False                                                                       (1)

2.2 FIGURE 2.2 on ANSWER SHEET A:

      2.2.1     Outside door at 2.2.A                                                       (2)
      2.2.2     Window at 2.2.B                                                             (2)
      2.2.3     Water closet at 2.2.C                                                       (2)
      2.2.4     Washbasin at 2.2.D                                                          (2)
      2.2.5     Single sink unit at 2.2.E                                                   (2)
      2.2.6     One-way switch single pole at 2.2.F                                         (2)
      2.2.7     Fluorescent light at 2.2.G                                                  (2)
      2.2.8     Socket outlet at 2.2.H                                                      (2)
      2.2.9     Grease trap at 2.2.I                                                        (2)
      2.2.10    Wall-mounted light at 2.2.J                                                 (2)

2.3 2.3.1       Trim hexagon

      2.3.2     Hex flange

      2.3.3     Square shoulder screws                                                       (3)

2.4 2.4.1       Dumpy level                                                                  (1)

      2.4.2     Any ONE use of this instrument:
                • Determine the difference in levels
                • Determine levels and slopes
                • Setting out buildings
                • Transferring levels and heights                               (1 x 1)      (1)

      2.4.3     A –     Focussing knob
                B –     Eye piece
                C –     Foot piece
                D –     Objective                                               (4 x 1)     (4)

      2.4.4     (1) To obtain a level / horizontal (2) sight line / reading                 (2)

2.5 (1) If the moisture inside the level freezes and later reaches normal operating
    temperature, the moisture can condense (2) inside the tool, where it may
    damage the circuit board                                                                (2)

2.6 M08 = Thread diameter
    25 = Thickness                                                                      (2)
                                                                                       [40]
                                                                      TOTAL SECTION A: 60

Copyright reserved                                                             Please turn over

### Page 4

Downloaded from hlayiso.com
4                            CIVIL TECHNOLOGY: CIVIL SERVICES                (EC/SEPTEMBER 2019)

QUESTION 3: SAFETY, MATERIAL AND CONSTRUCTION (SPECIFIC)

3.1 Displace dangerous fumes/gases                                                          (1)

3.2 Similar answer:
    (1) Worker not fall (2) into opening / in emergency to pull worker out                  (2)

3.3 3.3.1      Rope grab

      3.3.2    Locking snap hook

      3.3.3    D-clip                                                                       (3)

3.4 Zink is a (1) weak atomic bond (2) relative to other metals which during
    (3) dezincification (when zinc is removed from an alloy) (4) a weak deposit of
    porous/nobler/copper-rich metal will remain                                             (4)

3.5 Water with an acid content                                                              (1)

3.6 3.6.1      Electrode                                                                    (1)

      3.6.2    Boundary                                                                     (1)

      3.6.3    Electrolyte                                                                  (1)

      3.6.4    Passive                                                                      (1)

3.7 FIGURE 3.7 on ANSWER SHEET B shows layer 1 of a double return angle in
    a one-brick wall in stretcher bond. Draw the alternate layer of the one-brick wall
    on scale 1 : 10 on ANSWER SHEET B.                                                     (10)

3.8 Any TWO positions where manholes must be placed:
    • Before municipal connection
    • Every 20–25 m on a straight drain line
    • Change of direction
    • Change of gradient
    • Change of level
    • Important junctions                                                       (2 x 1)     (2)

3.9 3.9.1      False                                                                        (1)

      3.9.2    True                                                                         (1)

      3.9.3    True                                                                         (1)
                                                                                           [30]

Copyright reserved                                                              Please turn over

### Page 5

Downloaded from hlayiso.com
(EC/SEPTEMBER 2019)           CIVIL TECHNOLOGY: CIVIL SERVICES                               5

QUESTION 4:           COLD-WATER SUPPLY, HOT-WATER SUPPLY AND
                      EQUIPMENT (SPECIFIC)

4.1 (1) A fan turns a series of gears (2) that turn the meter dial and register the
    amount of water used                                                                   (2)

4.2 4.2.1     Stopcock                                                                     (1)

      4.2.2   A – Spindle
              B – Gland nut
              C – Jumper
              D – Compression fitting
              E – Washer                                                                   (5)

      4.2.3   G                                                                            (1)

      4.2.4   Any TWO positions where this type of tap can be installed.
              • Water service point
              • Water supply pipes to water closet cisterns
              • Regulating taps at showers                                      (2 x 1)    (2)

4.3 Water-saving attachment                                                                (1)

4.4 Cut off water supply                                                                   (1)

4.5 (1) Polluted water / sand particles (2) affects mechanisms of valves and taps          (2)

4.6 (1) When water heats up, (2) it rises                                                  (2)

4.7 4.7.1     D                                                                            (1)

      4.7.2   E                                                                            (1)

      4.7.3   G                                                                            (1)

      4.7.4   B                                                                            (1)

      4.7.5   C                                                                            (1)

4.8 4.8.1     (1) At least 1 m away (2) from the geyser                                    (2)

      4.8.2   (1) Must be supported by roof trusses (2) and have at least two legs         (2)

4.9 Direct solar hot-water system on ANSWER SHEET B

      4.9.1   Draw the pressure-relief valve, non-return valve and pressure-reducing
              valve symbols in the correct openings marked 4.9, in the pipe system.        (6)

      4.9.2   Draw the hot-water pipe system from the solar panels to the storage
              tank.                                                                        (5)

Copyright reserved                                                             Please turn over

### Page 6

Downloaded from hlayiso.com
6                         CIVIL TECHNOLOGY: CIVIL SERVICES             (EC/SEPTEMBER 2019)

4.10 Any THREE caring measures which are applicable to the pipe-thread cutting
     machine.
     • Maintain tools
     • Keep cutting tools sharp and clean
     • Check for misalignment of moving parts
     • Use only accessories that are recommended by the manufacturer      (3 x 1)     (3)
                                                                                     [40]

Copyright reserved                                                        Please turn over

### Page 7

Downloaded from hlayiso.com
(EC/SEPTEMBER 2019)            CIVIL TECHNOLOGY: CIVIL SERVICES                                7

QUESTION 5:           DRAINAGE, SANITARY FITMENTS AND QUANTITIES
                      (SPECIFIC)

5.1 5.1.1       Soil water. (1) Contains organic contaminants/human excretions
                (2) from water closet/urinals                                                (2)

      5.1.2     Waste water. (1) Water discharged from (2) sink / washbasin / hand
                basin / shower / bath                                                        (2)

5.2 Any similar answer:
    (1) The water be able to convey solids (2) for adequate flushing of the system/
    the system not be blocked                                                                (2)

5.3 5.3.1       Socket-and-spigot joint                                                      (1)

      5.3.2     Ring seal                                                                    (1)

      5.2.3     Keeps out aggressive groundwater/sandy soil and tree roots                   (1)

5.4 Fully describe the cause of a siphonic action in a drain system.

      (1) When waste water is suddenly (2) discharged from sanitary fixtures on
      (3) the upper floor, (4) it moves rapidly through the soil pipes. (5) It may suck
      some air from the lateral branch pipe, (6) resulting in the flow of the water from
      the trap.                                                                              (6)

5.5 5.1.1       True                                                                         (1)

      5.1.2     True                                                                         (1)

      5.1.3     False                                                                        (1)

      5.1.4     True                                                                         (1)

5.6 (1) Remove visible blockages. (2) Fill the sink with 3–4 cm of water. (3) Place
    the plunger over the opening and push down hard.                                         (3)

5.7 Any TWO properties:
    • Durable / strong
    • Pleasant, glazed surface
    • Different colours                                                          (2 x 1)     (2)

5.8 5.8.1       A – Inspection eye
                B – Soil-water pipe
                C – Pipe bend
                D – Gully
                E – Trap                                                                     (5)

      5.8.2     Cleaning / Removing blockages                                                (1)

      5.8.3     40 / 50 mm                                                                   (1)

Copyright reserved                                                               Please turn over

### Page 8

Downloaded from hlayiso.com
8                             CIVIL TECHNOLOGY: CIVIL SERVICES     (EC/SEPTEMBER 2019)

5.9     5.9.1        2                                                            (1)

        5.9.2        1,3 m + 1,3 m = 2,6 m (2 600 mm)                             (2)

        5.9.3        12 m (12 000 mm)                                             (1)

        5.9.4        2                                                            (1)

5.10    5.10.1       The volume of the tank in m³.
                     πr²h = 22 x 0,9 x 0,9 x 2,8 = 7,128 m³
                             7                                                    (3)

        5.10.2       The volume of water that the tank can hold.                  (1)
                     7,13 m³ x 1 000 = 7 128 ℓ                                   [40]

Copyright reserved                                                    Please turn over

### Page 9

Downloaded from hlayiso.com
(EC/SEPTEMBER 2019)           CIVIL TECHNOLOGY: CIVIL SERVICES                              9

QUESTION 6:           GRAPHICS AS A MEANS OF COMMUNICATION, ROOFWORK,
                      STORM WATER AND JOINING (SPECIFIC)

6.1 FIGURE 6.1 on ANSWER SHEET C shows the top and front elevations of a
    cylindrical pipe with a 45° cut-off.
    Draw the development of the pipe on ANSWER SHEET C.
    Show all construction lines.                                                         (21)

6.2 1 m                                                                                   (1)

6.3 (1) Water proofing of roofs (2) at junctions / where walls protrude above the roof    (2)

6.4 Channel water away from the house                                                     (1)

6.5 6.5.1      True                                                                       (1)

     6.5.2     False                                                                      (1)

     6.5.3     True                                                                       (1)

6.6 Any TWO:
    • Manufactured from pine-tree bark
    • Looks like gum
    • Not water soluble
    • Dissolves in spirits
    • Low melting point
    • Inflammable when heated to boiling point
    • Soldering brass, copper, tin and lead                                    (2 x 1)    (2)
                                                                                         [30]

                                                                             TOTAL:      200

Copyright reserved                                                            Please turn over

### Page 10

Downloaded from hlayiso.com
 10                           CIVIL TECHNOLOGY: CIVIL SERVICES                (EC/SEPTEMBER 2019)

                                 CIVIL TECHNOLOGY                   NAME:
   ANSWER SHEET           A           GENERIC

2.2     Use the information on ANSWER SHEET A and complete the floor plan to
        scale 1 : 100.

                                  2.2.I           2.2.J

                                             KITCHEN
                 2.2.C   2.2.D    2.2.E
           BATHROOM

                                             LIVING AREA

                  ROOM                                    2.2.G

                                     2.2.F         2.2.H

                                          2.2.A             2.2.B

                                                   Outside door at 2.2.A                2
                                                   Window at 2.2.B                      2
                                                   Water closet at 2.2.C                2
                                                   Wash basin at 2.2.D                  2
                                                   Single sink unit at 2.2.E            2
                                                   One-way switch-single pole at 2.2.F  2
                                                   Fluorescent light at 2.2.G           2
                                                   Socket outlet at 2.2.H               2
                                                   Grease trap at 2.2.I                 2
                                                   Wall-mounted light at 2.2.J          2
                                                                                 TOTAL: 20

 Copyright reserved                                                              Please turn over

### Page 11

Downloaded from hlayiso.com
(EC/SEPTEMBER 2019)                  CIVIL TECHNOLOGY: CIVIL SERVICES                         11

                                     CIVIL TECHNOLOGY       NAME:
ANSWER SHEET               B           CIVIL SERVICES

3.7    FIGURE 3.7 on ANSWER SHEET B shows layer 1 of a double return angle
       in a one-brick wall in stretcher bond. Draw the alternate layer of the one-
       brick wall on scale 1 : 10 on ANSWER SHEET B.                                     (10)

                                                               Brickwork               8
                                                               Application of scale    2
                                                                                TOTAL: 10

4.9 Complete the diagrammic representation of a pumped direct solar hot-water
    system on ANSWER SHEET B by drawing in the following parts:

  SOLAR PANELS                                               Pressure-relief valve      2
                                                             Non-return valve           2
                                                             Pressure-reducing valve    2
                                                             Hot water pipework         5
                               4.9                                              TOTAL: 11

                               PV
                      HR
                                                                   HOT WATER FEED

                                                          HOT WATER STORAGE TANK

                                                                        SERVICE PIPE

                                     4.9                     4.9

Copyright reserved                                                               Please turn over

### Page 12

Downloaded from hlayiso.com
          12                                             CIVIL TECHNOLOGY: CIVIL SERVICES                                  (EC/SEPTEMBER 2019)

                                                           CIVIL TECHNOLOGY                      NAME:
              ANSWER SHEET                       C           CIVIL SERVICES

          6.1      FIGURE 6.1 on ANSWER SHEET C shows the top and front elevations of a
                   cylindrical pipe with a 45° cut-off.
                   Draw the development of the pipe on ANSWER SHEET C.
                   Show all construction lines.                                         (21)

          .

                                         A7      C                                                B6                                                D
                                 A6
                                                                                        B5                   B7
                            A5                                                     B4                                 B8

                   A4                                                     B3                                                    B9

              A3                                                    B2                                                                B10
     A2                                                   B1                                                                                 B11
A1
                                                 A                                                                                                  B

                                                     0         1      2        3    4        5     6     7        8         9        10     11     12

                    3        4
              2
                                     5
 1

12
                                             6
 0

     11                                  7

              10                 8
                        9

                                                                   Base line A-B                                      1
                                                                   Seam lines A-C and B-D                             1
                                                                   Dividing lines 0-12 on top view                    6
                                                                   Vertical and horizontal construction lines A1–A7   7
                                                                   Intersection points and development lines B1–B11 6
                                                                                                               TOTAL: 21

          Copyright reserved                                                                                                    Please turn over

## Related documents

- [CIVIL TECH GR12 QP Eng SEPT2019 CIVIL SERVICES](https://www.hlayiso.com/library/civil-tech-gr12-qp-eng-sept2019-civil-services/24d2e0b8-d851-4c36-a274-0e7449793231) — Civil Technology · QP · 2019 · Eng
- [CIVIL TECH GR12 QP AFR SEPT2019 KONSTRUKSIE](https://www.hlayiso.com/library/civil-tech-gr12-qp-afr-sept2019-konstruksie/c3787049-358b-4ee5-a539-4188e9f548b5) — Civil Technology · QP · 2019 · Afr
- [CIVIL TECH QP GR12 SEPT 2019 Woodwork English](https://www.hlayiso.com/library/civil-tech-qp-gr12-sept-2019-woodwork-english/7eaa0222-4bca-4690-a584-eab0441f77d9) — Civil Technology · QP · 2019 · Eng
- [Civil Technology May June 2019 (Civil Services) Memo Afr](https://www.hlayiso.com/library/civil-technology-may-june-2019-civil-services-memo-afr/2a9b9e1b-37dc-48dc-9aa7-67dd5fa19a10) — Civil Technology · Memo · 2019 · Afr
- [Civil Technology May June 2019 (Civil Services) Memo Eng](https://www.hlayiso.com/library/civil-technology-may-june-2019-civil-services-memo-eng/8c1355fc-f6e2-40c6-85ff-1d03eb2991ea) — Civil Technology · Memo · 2019 · Eng
- [Civil Technology Nov 2019 (Civil Services) Memo Afr](https://www.hlayiso.com/library/civil-technology-nov-2019-civil-services-memo-afr/13c03cd5-cfa4-42cf-9a7c-5d7b0e1069f0) — Civil Technology · Memo · 2019 · Afr

## More from Grade 12 Civil Technology

- [Civil Technology (Woodwork) (English and Afrikaans) June 2025 Question Paper](https://www.hlayiso.com/library/civil-technology-woodwork-english-and-afrikaans-june-2025-question-paper/c8edd459-5237-48e0-8588-69d7ecd7f8e5) — QP · 2025 · Afr
- [Civil Technology May-June 2025 (Construction) Afr](https://www.hlayiso.com/library/civil-technology-may-june-2025-construction-afr/591d6ffd-20b1-4748-a1ba-b055be0a14c3) — QP · 2025 · Afr
- [Civil Technology Nov 2025 (Woodworking) Afr](https://www.hlayiso.com/library/grade-12-civil-technology-2025-nsc-november-exam-question-paper/05a95faf-5891-4d88-9e5e-7d13c1d21648) — QP · 2025 · Afr
- [CIV TECH GR12 QP SEPT2024 Woodworking Afrikaans](https://www.hlayiso.com/library/civ-tech-gr12-qp-sept2024-woodworking-afrikaans/1c6d5c64-83b5-456b-abcf-2abc23f1f1fe) — QP · 2024 · Afr
- [CIV TECH GR12 QP SEPT2024 Construction English](https://www.hlayiso.com/library/civ-tech-gr12-qp-sept2024-construction-english/12643629-87af-4230-a48a-002beb7f6cd7) — QP · 2024 · Eng
- [Civil Technology Nov 2024 (Woodworking) Afr](https://www.hlayiso.com/library/civil-technology-nov-2024-woodworking-afr/eefaae29-fe93-4b75-8223-87bf4f3fc14c) — QP · 2024 · Afr

## Collection

- [Grade 12 past papers](https://www.hlayiso.com/grade-12/past-papers)

---

Hlayiso: free CAPS and IEB past papers, memos, notes and study guides for South African learners. When citing, link the page URL above, not a PDF or /api/ URL.