# Electrical Technology Grade 12 Eastern Cape Mock 2020 Memo

> Grade 12 Electrical Technology memorandum from the Eastern Cape Mock Exam 2020 (Afrikaans), 12 pages. Read online or download the free PDF.

- Page: https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2020-afrikaans-power/3bf820c8-f427-4b77-acb6-9d1d1c1e44db
- Updated: 2026-09-27
- Subject: Electrical Technology
- Grade: Grade 12
- Language: Afrikaans
- Document type: Memorandum
- Year: 2020
- Exam period: Eastern Cape Mock Exam
- Curriculum: CAPS
- Pages: 12

Breadcrumbs: [Home](https://www.hlayiso.com/) › [Library](https://www.hlayiso.com/library) › [Grade 12](https://www.hlayiso.com/library/grade-12) › [Electrical Technology](https://www.hlayiso.com/library/grade-12/electrical-technology) › [Electrical Technology Grade 12 Eastern Cape Mock 2020 Memo](https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2020-afrikaans-power/3bf820c8-f427-4b77-acb6-9d1d1c1e44db)

## About this document

Electrical Technology · Grade 12 · Eastern Cape Mock Exam · 2020 · Afrikaans. Memorandum, 12 pages. Read online or download the PDF.

Read it free online on the page above; download the PDF from there.

## Document text

Text extracted from the PDF. Layout, diagrams and tables may not survive extraction.

### Page 1

Downloaded from hlayiso.com

                          NASIONALE
                      SENIOR SERTIFIKAAT

                                GRAAD 12

                       SEPTEMBER 2020

   ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS
               NASIENRIGLYN

PUNTE:   200

                 Hierdie nasienriglyn bestaan uit 12 bladsye.

### Page 2

Downloaded from hlayiso.com
 2                      ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS            (EC/SEPTEMBER 2020)

  INSTRUKSIES AAN NASIENERS

  1.   Alle vrae met veelvuldige antwoorde veronderstel dat enige relevante,
       aanvaarbare antwoord oorweeg moet word.

  2.   Berekeninge:

       2.1   Alle berekeninge moet formules toon.

       2.2   Vervanging van waardes moet korrek gedoen wees.

       2.3   Alle antwoorde MOET die korrekte eenheid bevat om oorweeg te
             word.

       2.4   Alternatiewe metodes moet oorweeg word, met die voorwaarde dat
             die korrekte antwoord verkry is.

       2.5   Wanneer ŉ verkeerde antwoord in 'n daaropvolgende berekening
             gebruik word, sal die aanvanklike antwoord as verkeerd beskou word.
             Indien die verkeerde antwoord egter daarna korrek toegepas word,
             moet die nasiener die antwoord weer uitwerk met die verkeerde
             waardes. Indien die kandidaat die aanvanklike verkeerde antwoord
             daaropvolgende korrek toegepas het, moet die kandidaat volpunte vir
             die daaropvolgende korrekte berekeninge kry.

       2.6   Nasieners moet in aanmerking neem dat kandidate se antwoorde
             effens van die nasienriglyne kan verskil, afhangend van waar en hoe
             daar in die berekening afgerond is.

  3.   Hierdie nasienriglyne is slegs ŉ gids met modelantwoorde.

  4.   Alternatiewe vertolkings moet oorweeg word en op meriete nagesien word.
       Hierdie beginsel moet konsekwent tydens die nasiensessie by ALLE
       nasiensentrums toegepas word.

Kopiereg voorbehou                                                      Blaai om asseblief

### Page 3

Downloaded from hlayiso.com
 (EC/SEPTEMBER 2020)     ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS                              3

  VRAAG 1: BEROEPSGESONDHEID EN VEILIGHEID

  1.1     Ongeluk beteken ŉ insident wat voortspruit uit en in die loop van die
          werknemer se werk en wat lei tot ŉ persoonlike besering, siekte  of die
          dood van die werknemer.                                                      (2)

  1.2      Sorg vir die gesondheid en veiligheid van hom-/haarself en ander
            persone wat deur sy of haar optrede geraak kan word. 
           Werk saam met die werkgewer of persone om die pligte wat deur die
            vereistes en prosedures verleen word, moontlik te maak. 
           Voer enige wettige bevel uit wat aan hom gegee is, en hou by die
            gesondheids- en veiligheidsreëls en prosedures neergelê deur sy
            werkgewer of deur iemand wat daar gemagtig is deur sy werkgewer, in
            die belang van gesondheid of veiligheid
           As daar ŉ onveilige of ongesonde situasie onder sy/haar aandag kom,
            moet jy dit so gou doenlik aan sy/haar werkgewer rapporteer, of ŉ
            gesondheid- en veiligheidsverteenwoordiger wat dit by die werkgewer
            moet aanmeld.                                                               (2)

  1.3        Spelery 
             Hardloop in die werkswinkel. 
             Dinge gooi
             Sakke, stoele of materiaal in die wandelgang agterlaat.
             Mors ŉ vloeistof of olie sonder om skoon te maak.
             Enige relevante antwoord                                                  (2)

  1.4     Derdegraadse brandwond: waar alle lae van die vel verbrand is, wat
          permanente velbeskadiging veroorsaak  wat vet, spiere en selfs been
          beïnvloed.                                                                   (2)

  1.5      Om die doeltreffendheid van gesondheids- en veiligheidsmaatreëls te
            hersien. 
           Om gevare en moontlike groot voorvalle op die werkplek te
            identifiseer.                                                              (2)
                                                                                       [10]

  VRAAG 2: RLC KRINGE

  2.1    2.1.1   Die stroom en die spanning is buite fase met mekaar  en die
                 stroom lei die spanning met 90°.                                       (2)

         2.1.2   Die stroom en die spanning is nie in fase met mekaar nie  en die
                 stroom is by die spanning met 90°.                                     (2)

         2.1.3   Die stroom en die spanning is in fase  en hul fasehoek is zero.      (2)

Kopiereg voorbehou                                                           Blaai om asseblief

### Page 4

Downloaded from hlayiso.com
 4                            ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS       (EC/SEPTEMBER 2020)

  2.2   2.2.1   𝑋𝐿 = 2𝜋𝐹𝐿 
                      = 2𝜋 × 60 × 44 × 10−3 
                      = 16,587 Ω                                                       (3)

        2.2.2                  1
                 𝑋𝑐 =                  
                          2𝜋𝐹𝐶
                                    1
                 𝑋𝑐 =                           
                          2𝜋×60×120

                𝑋𝑐 = 22,105 Ω                                                          (3)

        2.2.3   𝑍 = √𝑅2 + (𝑋𝐿 − 𝑋𝑐)2 
                     = √252 + (22,105 − 16,58)2 
                𝑍 = 25,6 Ω                                                             (3)
                                                                                           
        2.2.4            𝑉𝑇
                𝐼𝑇 =          
                         𝑍𝑇
                          120
                     =              
                          25,6

                     = 4,69 𝐴                                                          (3)
                                                                                           
  2.3   Die kapasitiewe reaktansie sal afneem  omdat die kapasitiewe
        reaktansie omgekeerd eweredig  aan die frekwensie is.                         (3)

  2.4   2.4.1   𝐼𝑇 = √𝐼𝑅2 + (𝐼𝐿 − 𝐼𝐶)2 
                     = √62 + (5 − 4)2 
                      = 6,08 𝐴                                                         (3)

        2.4.2                  𝐼𝑅
                𝐶𝑂𝑆𝜃 =              
                               𝐼𝑧
                                            6
                      𝜃 = 𝐶𝑜𝑠 −1                    
                                           6,08

                         = 9,305°                                                      (3)

        2.4.3            𝑉𝑇
                𝑋𝐿 =           
                         𝐼𝐿
                         240
                𝑋𝐿 =               
                          5

                𝑋𝐿 = 48 Ω                                                              (3)

        2.4.4            𝑉𝑇
                 𝑋𝑐 =              
                          𝐼𝐶
                         240
                𝑋𝐶 =               
                          4

                      = 60 Ω                                                           (3)

Kopiereg voorbehou                                                       Blaai om asseblief

### Page 5

Downloaded from hlayiso.com
 (EC/SEPTEMBER 2020)           ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS                5

  2.5 2.5.1                    1
                 𝐹𝑅 =                  
                          2𝜋√𝐿𝐶
                                       1
                 𝐹𝑅 =                          
                          2𝜋√0,2×0,05−6

                 𝐹𝑅 = 1 591,5 𝐻𝑧                                               (3)
        2.5.2
                 𝑋𝐿 = 2𝜋𝐹𝐿 
                 𝑋𝐿 = 2𝜋 × 1591,5 × 0,2
                 𝑋𝐿 = 1 999,938 Ω 
                          𝑋𝐿
                     𝑄=           
                           𝑅
                          1 999,938
                     𝑄=
                                  10

                     𝑄 = 200                                                   (4)

        2.5.3              𝐹𝑟
                 𝐵𝑊 =              
                              𝑄
                           1 591,5
                 𝐵𝑊 =                      
                               200

                        = 7,958 Hz                                             (3)

  2.6 2.6.1              𝐹𝑟
                 𝑄=               
                        𝐵𝑊
                         95×106
                 𝑄=                        
                        200×103

                 Q = 475 Hz                                                    (3)

        2.6.2                 1
                 𝑋𝑐 =                 
                          2𝜋𝐹𝐶
                                           1
                 𝑋𝑐 =
                          2𝜋×95×106 ×2,5×106

                 𝑋𝑐 = 22,105 Ω                                                 (2)

        2.6.3             𝑋𝐿
                  𝑅=              
                          𝑄
                         670
                  𝑅=
                         475

                       = 1,4466 Ω                                              (2)
                                                                               [50]

Kopiereg voorbehou                                                   Blaai om asseblief

### Page 6

Downloaded from hlayiso.com
 6                        ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS           (EC/SEPTEMBER 2020)

VRAAG 3: DRIEFASE-WS-OPWEKKING

3.1
                                                              R

                                          VF
                                                N        VL

                                                              Y

                                                              B

       Diagram korrek geteken 
       V𝐹 
       VL 
       Fases korrek benoem                                                           (4)

3.2    3.2.1 Die kilowatt-uur meter word gebruik om die hoeveelheid elektriese
             energie  wat oor ŉ sekere tydperk verbruik is, te meet.                (2)

       3.2.2 ŉ Toestel wat die krag wat deur ŉ toepassing verbruik word, meet.       (1)

3.3       Kan nie oor lang afstande ekonomies versprei word nie. 
          Nie geskik vir swaar gebruikstoepassings wat groot hoeveelhede krag
           benodig nie. 
          Gebruik groter strome en dus dikker kabels.
          Vir ŉ gelykwaardige toepassing is dit nie so ekonomies soos driefase
           nie.                                                          (Enige 2)    (2)

3.4     3.4.1   Die huidige spoele van die twee wattmeters word in serie aan die
                rooi en blou fases gekoppel.  Die twee wattmeters se spanning is
                aan mekaar  en aan die geel fase gekoppel.                          (3)

       3.4.2    PT = W1 + W2 
                     = 5 000 + 7 500 
                     = 12 500 W = 12,5 kW                                            (3)

                             P −P2
                tanθ = √3 ( 1        )
                             P1 +P2
                             5000−7500
                     = √3 (          )
                            5000+7500
                     = −0,35 
                   𝜃 = tan−1 (−0,35)
                     = −19,29° 
                Drywingsfaktor = cos(−19,29)
                               = 0,94 

Kopiereg voorbehou                                                       Blaai om asseblief

### Page 7

Downloaded from hlayiso.com
 (EC/SEPTEMBER 2020)            ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS                            7

 3.5   3.5.1               VL
                VPH =           
                           √3
                           380
                       =         
                           √3

                       = 219,39 V                                                          (3)

       3.5.2     P = √3VL IL cos θ
                                 P
                IL =                  
                         √3VL cos θ
                             25000
                     =                 
                         √3×380×0,8
                       = 47,48 A                                                           (3)

       3.5.3    𝑄 = √3VL IL sin θ                               θ = cos −1 0,8
                  = √3 × 380 × 47,48 × sin(cos −1 0,8) 
                  = 18 750,21 VAr = 18,75 kVAr                                             (3)

 3.6   Delta is ŉ driefasige, driedraad-toevoer en wonings benodig ŉ neutrale
       punt  om ŉ enkelfasespanning van 220 V te voorsien.                                (2)

 3.7   ŉ Lae drywingsfaktor veroorsaak nalopende strome.  Dit veroorsaak ŉ
       hoër stroomvloei vir ŉ gegewe las.  Namate die lynstroom toeneem, neem
       die spanningsval in die geleier toe,  wat kan lei tot ŉ laer spanning by die
       toerusting.                                                                         (4)

 3.8   3.8.1 Elektrisiteit word in kragstasies opgewek deur natuurlike gasse,
             steenkool, fossielbrandstof, kernbrandstof en wateraksie om dit na
             elektriese energie om te skakel. 
             Basiese brandstowwe verhit stoom om turbines aan te dryf wat
             groot kragopwekkers aandryf.                                                  (2)

       3.8.2 Die opgewekte elektrisiteit word verhoog na ŉ hoë spanning en
             dan in ŉ nasionale netwerk gevoer. 
             Van die nasionale netwerk word dit met oorhoofse kraglyne na
             verskillende kragstasies oorgedra.                                            (2)

       3.8.3        Kommersiële geboue 
                    Wonings
                    Bedrywe
                    Regeringsgeboue
                    Enige ander relevant antwoord                                         (1)
                                                                                          [40]

Kopiereg voorbehou                                                                Blaai om asseblief

### Page 8

Downloaded from hlayiso.com
 8                              ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS            (EC/SEPTEMBER 2020)

 VRAAG 4: DRIEFASE-TRANSFORMATORS

 4.1     Kern-tipe 
         Dop-tipe                                                                             (2)

 4.2     Die minerale-olie isoleer  en koel die windings af.                                 (2)

 4.3         Inverse definitiewe minimum tyd relê. 
             Oombliksoorstroom relê 
             Gebalanseerde aardfout relê
             Buchholz-relê                                                                    (2)

 4.4         Natuurlike olie, Natuurlike lug 
             Natuurlike Olie, Geforseerde lug 
             Geforseerde olie, Geforseerde lug
             Geforseerde olie, Geforseerde water                                              (2)

 4.5     Wedersydse induksie                                                                  (1)

 4.6.1   S = √3VLS ILS
                S
         ILS =      
                   √3VLS
                   20 000
              =
                  √3×500

              = 23,09 A                                                                       (3)

 4.6.2   VLP = VPHP = 6 000 V
                      VLS
         VPHS =             
                      √3
                      500
                  =         
                      √3

                  = 288,68 V 
                                    VPHP
         T. verhouding =                     
                                    VPHS
                                    6000
                                =            
                                    288,68

                                = 20,78 ∶ 1                                                   (6)

 4.6.3   𝑃𝐼𝑁𝑆𝐸𝑇 = 𝑆 cos 𝜃                              𝑃𝐼𝑁𝑆𝐸𝑇 = √3𝑉𝐿 𝐼𝐿 cos 𝜃
                = 2 0000 × 0,88                   OF          = √3 × 500 × 23,09 × 0,88 
                = 17 600 𝑊 = 17,6 𝑘𝑊                          = 17 596,94 𝑊 = 17,6 𝑘𝑊         (3)

 4.6.4           𝑃𝐼𝑁𝑆𝐸𝑇 −𝑃𝑉𝐸𝑅𝐿𝐼𝐸𝑆𝐸
         ŋ=                             × 100 
                       𝑃𝐼𝑁𝑆𝐸𝑇
                 20 000 − 160
             =                  × 100 
                    20000

             = 99,2%                                                                          (3)

Kopiereg voorbehou                                                              Blaai om asseblief

### Page 9

Downloaded from hlayiso.com
 (EC/SEPTEMBER 2020)     ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS                               9

 4.7     Transformators het geen bewegende onderdele nie,  en dit veroorsaak
         dat minder verliese ontwikkel,  en dit lewer ŉ beter kraglewering. 
         Transformators het ŉ meer doeltreffende ontwerp.                                (3)

 4.8     ŉ Transformator het geen bewegende dele vir induksie om plaas te vind
         nie.  Anders as GS-stroom, lewer die WS-stroom ŉ wisselvloed wat uitsit
         en ineenstort  om die beweging van die magneetveld wat nodig is vir
         induksie te produseer.                                                         (3)
                                                                                        [30]

 VRAAG 5: DRIEFASEMOTORS EN -AANSITTERS

 5.1    Glip is die verskil tussen die rotorsnelheid  en die roterende magnetiese
        veld van die stator.                                                            (2)

 5.2     Om magnetiese gebrom/geruis te verminder 
         Om ‘cogging’ te vermy 
         Verhoog die effektiewe verhouding van transformasie tussen stator en
          rotor.
         Verhoog die glip vir ŉ gegewe draaimoment.                   (Enige 2)         (2)

 5.3    5.3.1     Om te verseker dat die isolasie van die wikkeling nie beskadig
                  word nie  en die raam van die motor raak.                            (2)

        5.3.2     Lesing moet ten minste 1 MΩ wees.                                     (1)

 5.4    Om die beginspanning van die motorwikkeling te verminder.                       (1)

 5.5    5.5.1     Driefase-voorwaartse terugwaartse aansitter                           (1)

        5.5.2     Dit is elektriese ineenskakelingskontakte  wat verhoed dat beide
                  kontakore terselfdertyd gelaai word.                                  (2)

        5.5.3     Die voorwaartse kontakor is bekrag.  Die N/O F-kontaktor sluit
                  wat die voorwaartse kontakor bekrag nadat die begin-voor-knoppie
                  gelos is.  Terselfdertyd word die NT/F oopgemaak en dan
                  voorkom dit dat die omgekeerde kontaktor bekrag word  totdat
                  die stopknoppie ingedruk word.                                        (4)

        5.5.4     Om die motor outomaties van die toevoer te ontkoppel  in die
                  geval van buitensporige strome.                                       (2)

        5.5.5     As die stroombaan bekrag word,  sal die omgekeerde kontaktor
                  bekrag word en die motor sal in ŉ omgekeerde rigting loop.  As
                  die stopknoppie ingedruk word, sal die motor omgekeer loop sodra
                  die stopknoppie los is.  Die motor kan nie in die voor-rigting ry
                  nie.                                                                  (4)

Kopiereg voorbehou                                                            Blaai om asseblief

### Page 10

Downloaded from hlayiso.com
 10                           ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS                (EC/SEPTEMBER 2020)

 5.6

                                            H/K1

                                                                    Beide
                                                                 oorbelastings
                                                                    korrek

                              BEGIN 1

                                             H/K1

                                                                      Beide
                                  H/K1                              kontaktors
                                                          H/K2        korrek
                                                                                                 (6)

 5.7     VL = VPH = 380 VN
         PINSET = √3VL IL cos θ 
                  = √3 × 380 × 25 × 0,866 
                  = 14 249,58 W = 14,25 kW                                                      (3)

 5.8     Die snelheid van die roterende magneetveld  in die statorwindings.                    (2)
                  ns −nr
 5.9     Glip =            × 100 
                     ns
                  1 200 − 1 140
             =                    × 100 
                      1 200

             = 5%                                                                               (3)

 5.10       Toevoerspanning 
            Frekwensie 
            Spoed 
            Aangeslane stroom
            Uitsetkrag
            Kragfaktor                                                          (Enige 3)       (3)

 5.11    Nee,  die aangeslane frekwensie en spanning is nie vir Suid-Afrika wat
         380 V / 50 Hz gebruik, geskik nie.                                                    (2)
                                                                                               [40]

Kopiereg voorbehou                                                                Blaai om asseblief

### Page 11

Downloaded from hlayiso.com
 (EC/SEPTEMBER 2020)       ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS                              11

VRAAG 6: PROGRAMMEERBARE LOGIKABEHEERDERS (PLB’s)

6.1    6.1.1   D                                                                          (1)

       6.1.2   C                                                                          (1)

       6.1.3   A                                                                          (1)

       6.1.4   E                                                                          (1)

       6.1.5   B                                                                          (1)

6.2    Sagteware word geïnstalleer om data en instruksies aan ŉ rekenaar of PLC
       se kontroleprogram te verskaf,  om dit met die invoerapparatuur te laat
       kommunikeer,  om die gewenste uitvoer te bereik.                                  (3)

6.3    6.3.1                      A
                                                    B        UITSET 

                                                                                           (3)

       6.3.2
                             

                  A                                 A
                           >=1       UITSET   OF
                                                                                 UITSET
                  B
                                                     B
                                                                                           (3)

6.4    Dit is ŉ halfgeleier wat lig gebruik  om ŉ elektriese sein tussen stroombane
       of elemente van ŉ stroombaan oor te dra  en dit elektries geïsoleerd van
       mekaar te hou.                                                                     (3)

6.5       Veiligheid of sekuriteitstoestelle (ligstrale as skakelaar) vir motorhuis-
           deure 
          Beheer die helderheid van skerms van elektroniese toestelle (TV’s,
           rekenaars, telefone) 
          Skakel ligte outomaties aan                                        (Enige 2)    (2)

6.6    Die tydreëlaar word gebruik om ŉ ‘AAN’ of ‘AF’ vertraging  in die werking
       van ŉ PLC se logika-program te gee.                                                (2)

Kopiereg voorbehou                                                              Blaai om asseblief

### Page 12

Downloaded from hlayiso.com
 12                     ELEKTRIESE TEGNOLOGIE: KRAGSTELSELS    (EC/SEPTEMBER 2020)

 6.7

                                           BEGIN        H/K1

                          H/K1              H/K1

                           N/T
                           H/K1
                                                                               (9)
                                                                              [30]

                                                               TOTAAL:         200

Kopiereg voorbehou                                              Blaai om asseblief

## Related documents

- [Electrical Technology PAT GR 12 2020 (Electronics) Afr](https://www.hlayiso.com/library/electrical-technology-pat-gr-12-2020-electronics-afr/0bb1bc18-1e0e-4585-bd39-fe4fdc8e6873) — Electrical Technology · PAT · 2020 · Afr
- [ELEC TECH QP SEPT2023 Power Afrikaans](https://www.hlayiso.com/library/elec-tech-qp-sept2023-power-afrikaans/f439f817-47a3-42b4-8762-e49f2c6ca1f2) — Electrical Technology · QP · 2023 · Afr
- [ELEC TECH QP SEPT2023 Electronics Afrikaans](https://www.hlayiso.com/library/elec-tech-qp-sept2023-electronics-afrikaans/f94a8c28-7fd6-4556-9263-d3c58461df27) — Electrical Technology · QP · 2023 · Afr
- [ELEC TECH QP SEPT2023 Digital Afrikaans](https://www.hlayiso.com/library/elec-tech-qp-sept2023-digital-afrikaans/70991b22-194b-42c5-a61f-97cf808eb68d) — Electrical Technology · QP · 2023 · Afr
- [ELEC TECH GR12 QP SEPT2022 Digital Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2022-digital-afrikaans/f569ad75-66e9-41b4-b833-cbbbe275bb53) — Electrical Technology · QP · 2022 · Afr
- [ELECTRICAL TECH-S18-AFRIK-DIGITAL ELEC](https://www.hlayiso.com/library/electrical-tech-s18-afrik-digital-elec/645306f1-7c04-42dd-b0a4-473f1e815955) — Electrical Technology · QP · 2018 · Afr

## More from Grade 12 Electrical Technology

- [Gr 12 Dig Elec ATP 2023-24](https://www.hlayiso.com/library/gr-12-dig-elec-atp-2023-24/8d3b2ee7-1d14-498d-a86b-d9fc34674531) — ATP
- [ELEC TECH GR12 QP SEPT2024 Electronics Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-electronics-afrikaans/6fc3719e-6eab-469e-baf1-ca1645c8ebad) — QP · 2024 · Afr
- [ELEC TECH GR12 QP SEPT2024 Power Systems Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-power-systems-afrikaans/928e510b-68c2-4670-a7c7-fe20b388befb) — QP · 2024 · Afr
- [Electrical Technology Nov 2024 (Electronics) Eng](https://www.hlayiso.com/library/electrical-technology-nov-2024-electronics-eng/870e3d22-85e9-42bd-890f-3ef1fd3333cf) — QP · 2024 · Eng
- [Electrical Technology Nov 2024 (Electronics) Afr](https://www.hlayiso.com/library/electrical-technology-nov-2024-electronics-afr/98972424-ba56-4bbc-a319-fdfc1fec40f8) — QP · 2024 · Afr
- [Electrical Technology Nov 2024 (Power Systems) Afr](https://www.hlayiso.com/library/electrical-technology-nov-2024-power-systems-afr/5f2b4850-fffb-4024-8f24-d74bd8677a25) — QP · 2024 · Afr

## Collection

- [Grade 12 past papers](https://www.hlayiso.com/grade-12/past-papers)

---

Hlayiso: free CAPS and IEB past papers, memos, notes and study guides for South African learners. When citing, link the page URL above, not a PDF or /api/ URL.