# Electrical Technology Grade 12 NSC June 2021 Memo (English)

> Grade 12 Electrical Technology memorandum from the NSC June Exam 2021 (English), 14 pages. Read online or download the free PDF.

- Page: https://www.hlayiso.com/library/electrical-technology-may-june-2021-power-systems-mg-eng/8a8f1c7e-856a-424b-a98c-cd41dda0d11d
- Updated: 2026-10-29
- Subject: Electrical Technology
- Grade: Grade 12
- Document type: Memorandum
- Year: 2021
- Exam period: NSC June Exam
- Curriculum: CAPS
- Pages: 14

Breadcrumbs: [Home](https://www.hlayiso.com/) › [Library](https://www.hlayiso.com/library) › [Grade 12](https://www.hlayiso.com/library/grade-12) › [Electrical Technology](https://www.hlayiso.com/library/grade-12/electrical-technology) › [Electrical Technology Grade 12 NSC June 2021 Memo (English)](https://www.hlayiso.com/library/electrical-technology-may-june-2021-power-systems-mg-eng/8a8f1c7e-856a-424b-a98c-cd41dda0d11d)

## About this document

Electrical Technology · Grade 12 · NSC June Exam · 2021. Memorandum. Read online or download the PDF.

Read it free online on the page above; download the PDF from there.

## Document text

Text extracted from the PDF. Layout, diagrams and tables may not survive extraction.

### Page 1

Downloaded from hlayiso.com

             SENIOR CERTIFICATE EXAMINATIONS/
         NATIONAL SENIOR CERTIFICATE EXAMINATIONS

                 ELECTRICAL TECHNOLOGY: POWER SYSTEMS

                                          2021

                                MARKING GUIDELINES

                                                                       MARKS: 200

                      These marking guidelines consist of 14 pages.

Copyright reserved                                                    Please turn over

### Page 2

Downloaded from hlayiso.com
Electrical Technology: Power Systems               2                                DBE/2021
                                       SC/NSC – Marking Guidelines

INSTRUCTIONS TO THE MARKERS

1.        All questions with multiple answers imply that any relevant, acceptable
          answer should be considered.

2.        Calculations:

          2.1         All calculations must show the formulae.

          2.2         Substitution of values must be done correctly.

          2.3         All answers MUST contain the correct unit to be considered.

          2.4         Alternative methods could be considered, provided that the correct
                      answer is obtained.

          2.5         Where an incorrect answer could be carried over to the next step,
                      the first answer will be deemed incorrect. However, should the
                      incorrect answer be carried over correctly, the marker has to re-
                      calculate the values, using the incorrect answer from the first
                      calculation. If correctly used, the candidate should receive the full
                      marks for subsequent calculations.

3.        This memorandum is only a guide with model answers. Alternative
          interpretations must be considered and marked on merit. However, this
          principle should be applied consistently throughout the marking session at
          ALL marking centres.

Copyright reserved                                                             Please turn over

### Page 3

Downloaded from hlayiso.com
Electrical Technology: Power Systems               3                               DBE/2021
                                       SC/NSC – Marking Guidelines

QUESTION 1: OCCUPATIONAL HEALTH AND SAFETY

1.1       'Safe' means free from any hazard.                                                    (1)

1.2       Discipline. 
          Sense of teamwork. 
          Emphasis on quality.
          Integrity.
          Sense of responsibility.                                                               (2)

1.3       The use of power tools. 
          The handling of hand tools.
          The use of etching acid and other chemicals.                                           (1)

1.4       Poor ventilation reduces the correct amount of oxygen which might lead to
          drowsiness. 
          Covid-19 protocols also refer to proper ventilation that must be adhered to.           (2)

1.5       To take reasonable care for the health and safety of himself/herself and
          others who may be affected by his/her act. 
          Cooperate with the employer or persons to enable that any duty given by the
          employer to the employee shall be performed or complied with according to
          the requirements and procedures.                                                      (2)

1.6       Human rights ensure human dignity  and that people are treated with
          respect and not exploited.                                                            (2)
                                                                                                 [10]

QUESTION 2: RLC CIRCUITS

2.1       2.1.1       Phase angle is the shift in phase between the supply voltage  and
                      the current  in a circuit which contain reactances and resistances.       (2)

          2.1.2       Capacitance is the ability of a capacitor to store an electric
                      charge.                                                                   (1)

2.2       It will affect the phase angle. 
          It will oppose the current flow in the circuit. 
          Lenz’s law states that when alternating current flows through an inductor, a
          back emf is set up which is opposite to the applied voltage.                           (2)

2.3       2.3.1                                            
                                                           
                                                           
                                                                                                 (3)

Copyright reserved                                                            Please turn over

### Page 4

Downloaded from hlayiso.com
Electrical Technology: Power Systems                   4                            DBE/2021
                                           SC/NSC – Marking Guidelines

          2.3.2              √         (           )           
                             √             (               )
                                                               
                                                                                                 (3)

          2.3.3       Inductive circuit.  The inductive reactance is greater than the
                      capacitive reactance.                                                      (2)

2.4       2.4.1              VT                                
                      IC 
                             XC
                          300                                  
                        
                           50
                         6A                                   
                                                                                                  (3)

          2.4.2                                                

                                                               

                                                                                                 (3)

          2.4.3                                                
                             √             (       )
                                                               
                             √         (       )
                                                                                                 (3)

          2.4.4                 I                              
                      θ  Cos 1 R
                                IT
                                                               
                                 41
                         Cos
                                 5
                         36,87 0
                                                                                                 (3)

2.5       2.5.1       Impedance.                                                                 (1)

          2.5.2       Capacitive reactance is greater  than the inductive reactance.            (2)

          2.5.3       The inductive reactance is represented by a straight line because it
                      is directly proportional to the frequency  of the supply voltage and
                      the capacitive reactance is represented by the curved line because
                      it is indirectly proportional to the frequency of the supplied
                      voltage. 
                      The Reactance value of a capacitor has a very high value at low
                      frequencies but quickly decreases as the frequency across it
                      increases.                                                                  (2)

Copyright reserved                                                             Please turn over

### Page 5

Downloaded from hlayiso.com
Electrical Technology: Power Systems               5                                DBE/2021
                                       SC/NSC – Marking Guidelines

          2.5.4                 1                          
                      fr 
                              2π LC
                                                           
                                        1
                          
                            2π 2,12  1,47  10 6
                           90,16 Hz                       
                                                                                                  (3)

          2.5.5       Tuning circuits. 
                      Radio circuits.
                      Oscillator circuits.
                      TV circuits.
                      Filter circuits.
                      Band pass filter.                                                           (1)

2.6       2.6.1       The higher the value of the Q-factor the greater the value of the
                      current flow.                                                              (1)

          2.6.2       Half power points are the upper and lower cut off frequencies in a
                      circuit. 
                      Point at which the output power has dropped to half of its peak
                      value, at a level of approximately -3db.                                    (1)

          2.6.3           The value of the series resistor. 
                          The inductor/capacitor (L/C) ratio.                                   (2)

          2.6.4       As the Q factor of the circuit is lowered, its selectivity decreases
                      and its bandwidth increases.                                               (2)
                                                                                                  [40]

QUESTION 3: THREE-PHASE AC GENERATION

3.1       3.1.1       Efficiency of a three-phase system is the ratio of the output
                      power  to the input power.                                                (2)

          3.1.2       Power factor correction is the process of introducing reactive
                      elements  to improve the power factor.                                    (2)

3.2          Installations costs are very high. 
             Not available everywhere. 
             Not suitable for most residential applications. 
             Appliances operating with three phase supply are expensive.                         (3)

3.3       3.3.1       The value of the phase voltage (Vph) is equal to the value of the
                      line voltage (VL)  (Vph = VL)                                              (1)

Copyright reserved                                                             Please turn over

### Page 6

Downloaded from hlayiso.com
Electrical Technology: Power Systems                6                           DBE/2021
                                        SC/NSC – Marking Guidelines

          3.3.2                    B     
                                                         

                                             120o

                            120o                             R

                                             120o
                                                

                                  Y

                      NOTE:            1 mark for rotation
                                       1 mark for the correct sequence
                                       1 mark for the phase angle                             (3)

3.4       The generated electricity is less at the point of distribution because of the
          copper losses  occurring inside the transmission lines  and transformers
          during power transmission.                                                          (2)

3.5       3.5.1       The current through a capacitor leads the voltage by 90
                      degrees  and it will as a result reduce  the inductive lagging
                      current.
                      Capacitors draw leading currents which neutralise the lagging
                      currents.                                                               (2)

          3.5.2           Reduced supply current. 
                          Thinner supply conductors are required 
                          Reduced cost of thinner conductors
                          Reduced maintenance of supply equipment                            (2)

3.6       3.6.1                VL
                          VPH                       
                                3
                               380
                                                    
                                 3
                              219,39 V              
                                                                                              (3)
          3.6.2       P  S  cos θ                  
                         250 000  0,9              
                         225 000 W
                         225 kW                     
                                                                                              (3)

Copyright reserved                                                         Please turn over

### Page 7

Downloaded from hlayiso.com
Electrical Technology: Power Systems               7                                DBE/2021
                                       SC/NSC – Marking Guidelines

          3.6.3        θ  cos 1 0,9               
                          25,84ο                     

                      Q  S  sinθ                    
                         250 000  sin25,84        
                         108 964,88 VA r
                          109 kVA r                                                             (5)

3.7       The kilowatt-hour meter is used to measure the energy  consumed by a
          load.                                                                                  (2)
                                                                                                  [30]

QUESTION 4: THREE-PHASE TRANSFORMERS

4.1          Air Forced.  (AF)
             Air Natural.  (AN)                                                                 (2)

4.2          Losses 
             Transformer loading                                                                 (1)

4.3          Assemble or modify the circuit ONLY when the supply is OFF. 
             Do not switch the circuit ON before a supervisor (teacher) has inspected
              and is satisfied. 
             NEVER touch any bare electric wire or terminal.
             Exercise extreme care during experiments.
             After a practical, wait for the transformer to cool down before returning it
              back to the store room.
             Be very careful of the secondary terminals of a live open circuit
              transformer. Even after switch off, the transformer can store very high
              (fatal) voltages on the secondary coil.
             Earth the metal parts of a transformer.                                             (2)

4.4       4.4.1       Delta/star                                                                 (1)

          4.4.2       Industry or commercial sites where both single and three-phase
                      power is needed. 
                      Domestic distribution networks where only single phase power is
                      needed.                                                                    (2)

          4.4.3       It is a step-down  transformer because the turns ratio is 5:1.            (2)

4.5       4.5.1       To supply the same loads, single phase transformers become
                      more expensive  than three phase transformers.                             (1)

          4.5.2       Three phase transformers are more efficient  than single phase
                      transformers.                                                               (1)

Copyright reserved                                                             Please turn over

### Page 8

Downloaded from hlayiso.com
Electrical Technology: Power Systems                      8                                        DBE/2021
                                              SC/NSC – Marking Guidelines

4.6          When a fault occurs inside a transformer the oil heats up and gas forms
              inside the oil  depending on the severity of the fault.
             The heated oil and gas flows from the main tank though the Buchholz
              relay into the conservator tank. 
             A continuous slow formation of gas will cause the Buchholz relay to
              activate the alarm system. 
             The alarm indicates that there is a small fault in the system that needs
              close monitoring. 
             The moment that there is a severe fault, a big amount of gas is formed
              and the flow rate is also increased. 
             This increased gas formation will immediately activate the Buchholz relay
              isolating the transformer from the supply  and protecting it from the any
              further damage.                                                                                    (6)

4.7       4.7.1       Vph1          N1                       
                                
                      Vph2          N2
                                    N2  Vph1
                      Vph2 
                                         N1
                                  1 2 000                   
                                
                                      5
                                 400 V                                                                         (3)

          4.7.2                 POUT                         
                      η
                            POUT  losses
                             45000
                                      100                  
                          45000  500
                         98.9 %                                                                                (3)

          4.7.3                   P                          
                      Cos θ 
                                  S
                                  45 000                     
                                
                                  50 000
                                 0,9                                                                           (3)

          4.7.4                           P                                          S
                     IL2                                                   IL2 
                                    3  VL2  cos θ                                 3  VL2
                                 45 000                           OR             50 000
                                                                              
                               3  400  0,9                                      3  400
                             72,17 A                                          72,17 A                         (3)
                                                                                                                 [30]

Copyright reserved                                                                            Please turn over

### Page 9

Downloaded from hlayiso.com
Electrical Technology: Power Systems               9                                DBE/2021
                                       SC/NSC – Marking Guidelines

QUESTION 5: THREE-PHASE MOTORS AND STARTERS

5.1       5.1.1       A – End ring 
                      B – Bearing                                                                (2)

          5.1.2          Less maintenance due to no brushes or slip rings. 
                         They are less prone to explosions because any sparks are
                          eliminated due to the absence of brushes and slip rings.                (1)

          5.1.3          It helps in the reduction of magnetic hum. 
                         It helps to avoid cogging. (locking tendency of the rotor)
                         It increases the effective ratio of transformation between stator
                          and rotor.
                         It causes an increased rotor resistance due to comparatively
                          lengthier rotor conductor rods.
                         Increased slip for a given torque.                                      (1)

5.2       5.2.1       Slip is the difference  between the synchronous speed and the
                      rotor speed of an induction motor expressed in a percentage.                (2)

          5.2.2       Commissioning is when the electric motor is connected to the
                      power supply and the load  after all inspections (electrical and
                      mechanical) have been completed. 
                      The motor is certified and ready to be used.                                (2)

5.3       Inspect the:
           Mounting bolts to check if it is properly tightened. 
           Endplates to check if it is securely fastened.
           Frame for any cracks.
           Shaft for any play on it.
           Shaft if it turns freely by hand.
           Cooling fan if it is intact.
           Bearings for smooth movement when turned by hand.
           Bearing housings for excess grease or dust.                                           (1)

5.4       5.4.1                                  12
                               poles per phase 
                                                 3
                                               4                    
                                                 4
                      pole pairs per phase (p) 
                                                 2
                                                2 pole pairs        
                                                                                                  (2)

          5.4.2             f  60            
                      ns 
                               p
                                              
                            50  60
                          
                                2
                           1500 rpm                                                             (3)

Copyright reserved                                                             Please turn over

### Page 10

Downloaded from hlayiso.com
Electrical Technology: Power Systems              10                              DBE/2021
                                       SC/NSC – Marking Guidelines

          5.4.3       n r  n s  n s  slip         
                                           3         
                           1500  1500      
                                          100 
                           1455 rpm                                                           (3)

          5.4.4             PIN  losses
                      η                  100         
                                PIN
                          25 000 - 800                 
                                       100
                            25 000
                         96,8 %                       
                                                                                                (3)

5.5       5.5.1       Forward reverse control circuit.                                         (1)

          5.5.2       (a) OLN/C will open  the moment the current surpasses the pre-
                          set rated current, stopping the current flow to MC1,  and thus
                          stopping the motor.                                                   (2)

                      (b) MC2N/O is the retain contact  for the reverse
                          contactor  ensuring that current continues to flow to MC2,
                          after the start button is released.                                   (2)

          5.5.3       MC1 N/C is used as an interlocking contact.  When MC1 (forward)
                      is activated MC1N/C will open ensuring that MC2 cannot be
                      activated when MC1 is active.                                            (2)

5.6                                        
                I
          IFL  MAX
                  n
                100                        
              
                  7                                                                            (3)
               14,29 A                                                                         [30]

Copyright reserved                                                           Please turn over

### Page 11

Downloaded from hlayiso.com
Electrical Technology: Power Systems              11                                       DBE/2021
                                       SC/NSC – Marking Guidelines

QUESTION 6: PROGRAMMABLE LOGIC CONTROLLERS (PLCs)

6.1
                                                     READ INPUTS     

                                 ADJUST
                                 OUTPUTS
                                                                       RUN
                                                                     PROGRAM         

                                                  OR

                       Read inputs              Run program              Adjust outputs
                                                                                                         (3)

6.2          A PLC system would use fewer relays, cam controllers, timers, and
              counters. 
             Control panels would not have to be re-wired when production models
              were changed.  (Hardware)
             A PLC system physically takes up less space than Hardwired systems.
             A PLC system is cheaper when compared to large bulky relays and their
              cabinets.
             System upgrade is easier and faster. (Software)                                            (2)

6.3       The PLC wiring and connections must be checked before switching on to
          ensure that:
           There is no incorrect wiring 
           There are no loose connections                                                              (2)

6.4          All processing is done at low voltages and therefore safer. 
             The normal operation of a plant can be observed electronically on a
              monitor keeping the observer away from dangerous machines. 
             All operations are shown on the interface as machines turned on and
              faulty contactors can be located without having to fault find on a live
              system.
             Part of a plant can be switched off digitally for repairs to be done.                      (2)

Copyright reserved                                                                    Please turn over

### Page 12

Downloaded from hlayiso.com
Electrical Technology: Power Systems              12                                  DBE/2021
                                       SC/NSC – Marking Guidelines

6.5       6.5.1          The unit that performs all logic operations internally. 
                         It runs the ladder program.                                              (2)

          6.5.2       Soft-wired systems perform many functions digitally  to reduce
                      the amount of wiring in a circuit.                                           (2)

          6.5.3          PLC software is a program that is written into the unit to control
                          its functions. 
                         PLC software is the program used to compile the ladder logic
                          program.                                                                  (1)

6.6          An analogue signal is a continuously changing signal. 
             A digital signal is a signal with a number of discrete steps.                        (2)

6.7       6.7.1          Markers are used to hold data  in the PLC program.
                         They can be switched on or off and control other programs or
                          output devices.
                         They can be used to indicate when a certain stage in a program
                          is complete.
                         They can be used to indicate the start of the timing processor’s
                          next event.                                                               (1)

          6.7.2          The contactor on the program drives the coil on the relay
                          contact. 
                         It can be programmed to be normally closed or normally open
                          contacts.
                         They can control single phase or three phase contactors.                  (1)

6.8                                                                     
                                                                    Output
                                       A

                                           
                                       B

                                                        OR

                                                                     Output
                                       A           B

                                                                                                    (3)

Copyright reserved                                                               Please turn over

### Page 13

Downloaded from hlayiso.com
Electrical Technology: Power Systems              13                                       DBE/2021
                                       SC/NSC – Marking Guidelines

6.9       6.9.1        A sensor is a device that detects and converts an environmental
                       condition  into an electrical signal  that can be used by another
                       device for a particular purpose.                                                 (2)

          6.9.2              Temperature sensor 
                             Light sensor                                                             (2)
                             Overload sensor.
                             Level sensor.

          6.9.3              To detect the proximity of an object in relation to its distance 
                             Used to measure rotating speed                                           (2)

6.10

                                                                                  MC1 
               OL 1
                                  Stop              Start MC1

                                                          
                                                      MC1N/O

                                                                                  MC2 
            MC1N/O2                OL 2          Start MC2 

                                                          
                                                      MC2N/O

                                                        OR

                     Stop                      OL 1                                 MC1
                                                                   Start MC1

                                                                      MC1N

                                MC1N/O2        OL 2               Start MC2        MC2

                                                                      MC2N/O

                                                                                                        (10)

Copyright reserved                                                                   Please turn over

### Page 14

Downloaded from hlayiso.com
Electrical Technology: Power Systems              14                                 DBE/2021
                                       SC/NSC – Marking Guidelines

6.11         ON-delay 
             OFF-delay 
             ON/OFF-delay                                                                      (2)

6.12         When the start button is pressed, coil MC will be energised,
             Contact MCN/O1 will close  (Retention)
             Contact MCN/O2 will close  and the lamp will be 'ON'.
             The lamp will remain ON, until the stop button is pressed.                       (4)

6.13         Transistor 
             Relay                                                                            (2)

6.14      6.14.1         Regenerative braking block diagram. 
                         VSD control system with a load                                        (1)

          6.14.2      The braking resistor is connected to the circuit to dissipate
                      excessive regenerated energy.  The resister heats up and emits
                      heat. 
                      It protects the DC capacitors of a VSD from being overloaded.             (2)

6.15      The regenerated energy can be converted  into another form of energy 
          where it is stored and used when necessary.                                          (3)

6.16      6.16.1         AC to DC Converter 
                         Rectifier                                                            (1)

          6.16.2      Capacitors                                                               (1)

          6.16.3         The inverter, inverts the DC voltage back to AC voltage at a
                          different frequency. 
                         by switching the Insulated Gate Bipolar Transistor ON and OFF
                          at a high frequency. 
                         The ON and OFF times (width of the pulses) are carefully
                          controlled (PWM) with three pairs of switches. 
                         For every pair of switches, one switch controls the positive
                          part of the output voltage, the other switch controls the negative
                          part of the output voltage. 
                         The frequency of switching controls the rotation speed.               (5)

          6.16.4         Energy savings 
                         Better speed control of motors 
                         Better power factor
                         Smooth starting of motors                                             (2)
                                                                                                [60]

                                                                                   TOTAL:       200

Copyright reserved

## Related documents

- [Electrical Technology May June 2021 (Digital) Eng](https://www.hlayiso.com/library/electrical-technology-may-june-2021-digital-eng/c3a468e5-d3ba-4a27-b30b-3dc5074ce0fc) — Electrical Technology · QP · 2021 · Eng
- [Electrical Technology May June 2021 (Power Systems) Eng](https://www.hlayiso.com/library/electrical-technology-may-june-2021-power-systems-eng/f9d127bc-4db0-4b30-875a-c9b86afeacdd) — Electrical Technology · QP · 2021 · Eng
- [Electrical Technology May-June 2023 (Power Systems) MG Afr](https://www.hlayiso.com/library/electrical-technology-may-june-2023-power-systems-mg-afr/d3e896ed-f4d8-4c2a-9cac-f812d2b1a6b1) — Electrical Technology · Memo · 2023 · Afr
- [Electrical Technology May June 2018 Memo Eng](https://www.hlayiso.com/library/electrical-technology-may-june-2018-memo-eng/af9f7f90-5412-4c48-96fa-c3de2254a2f4) — Electrical Technology · Memo · 2018 · Eng
- [Electrical Technology May June 2018 Memo Afr](https://www.hlayiso.com/library/electrical-technology-may-june-2018-memo-afr/18563e52-7797-448e-a6eb-45ce7127e42f) — Electrical Technology · Memo · 2018 · Afr
- [Electrical Technology GR 12 Exam Guidelines (Digital) 2021 Afr](https://www.hlayiso.com/library/electrical-technology-gr-12-exam-guidelines-digital-2021-afr/58f5b52f-558e-41b3-bc3e-4cdfecda8b67) — Electrical Technology · Guideline · 2021 · Afr

## More from Grade 12 Electrical Technology

- [Gr 12 Dig Elec ATP 2023-24](https://www.hlayiso.com/library/gr-12-dig-elec-atp-2023-24/8d3b2ee7-1d14-498d-a86b-d9fc34674531) — ATP
- [Electrical Technology (Power Systems) (English) June 2025 Question Paper](https://www.hlayiso.com/library/electrical-technology-power-systems-english-june-2025-question-paper/5422e67a-03a4-4202-ba9b-1b9ec9872537) — QP · 2025 · Eng
- [ELEC TECH GR12 MEMO SEPT2024 Digital English](https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2024-digital-english/cb603860-b00d-40c2-a36b-aa5e97b7d1e5) — Memo · 2024 · Eng
- [ELEC TECH GR12 QP SEPT2024 Electronics Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-electronics-afrikaans/6fc3719e-6eab-469e-baf1-ca1645c8ebad) — QP · 2024 · Afr
- [ELEC TECH GR12 QP SEPT2024 Power Systems Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-power-systems-afrikaans/928e510b-68c2-4670-a7c7-fe20b388befb) — QP · 2024 · Afr
- [ELEC TECH GR12 QP SEPT2024 Digital English](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-digital-english/9fcfef2b-6d5e-4601-853a-24a2a3993617) — QP · 2024 · Eng

## Collection

- [Grade 12 past papers](https://www.hlayiso.com/grade-12/past-papers)

---

Hlayiso: free CAPS and IEB past papers, memos, notes and study guides for South African learners. When citing, link the page URL above, not a PDF or /api/ URL.