# Electrical Technology Grade 12 NSC June 2022 Memo (English)

> Grade 12 Electrical Technology memorandum from the NSC June Exam 2022 (English), 14 pages. Read online or download the free PDF.

- Page: https://www.hlayiso.com/library/electrical-technology-may-june-2022-power-systems-mg-eng/16cc9373-1332-4890-bcf2-0f36efb03d8d
- Updated: 2026-10-29
- Subject: Electrical Technology
- Grade: Grade 12
- Document type: Memorandum
- Year: 2022
- Exam period: NSC June Exam
- Curriculum: CAPS
- Pages: 14

Breadcrumbs: [Home](https://www.hlayiso.com/) › [Library](https://www.hlayiso.com/library) › [Grade 12](https://www.hlayiso.com/library/grade-12) › [Electrical Technology](https://www.hlayiso.com/library/grade-12/electrical-technology) › [Electrical Technology Grade 12 NSC June 2022 Memo (English)](https://www.hlayiso.com/library/electrical-technology-may-june-2022-power-systems-mg-eng/16cc9373-1332-4890-bcf2-0f36efb03d8d)

## About this document

Electrical Technology · Grade 12 · NSC June Exam · 2022. Memorandum. Read online or download the PDF.

Read it free online on the page above; download the PDF from there.

## Document text

Text extracted from the PDF. Layout, diagrams and tables may not survive extraction.

### Page 1

Downloaded from hlayiso.com

             SENIOR CERTIFICATE EXAMINATIONS/
         NATIONAL SENIOR CERTIFICATE EXAMINATIONS

                 ELECTRICAL TECHNOLOGY: POWER SYSTEMS

                                          2022

                                MARKING GUIDELINES

                                                                       MARKS: 200

                      These marking guidelines consist of 14 pages.

Copyright reserved                                                    Please turn over

### Page 2

Downloaded from hlayiso.com
Electrical Technology: Power Systems             2                                  DBE/2022
                                  SC/NSC – Marking Guidelines

INSTRUCTIONS TO THE MARKERS

1.        All questions with multiple answers imply that any relevant, acceptable
          answer should be considered.

2.        Calculations:

          2.1         All calculations must show the formulae.

          2.2         Substitution of values must be done correctly.

          2.3         All answers MUST contain the correct unit to be considered.

          2.4         Alternative methods must be considered, provided that the correct
                      answer is obtained.

          2.5         Where an incorrect answer could be carried over to the next step,
                      the first answer will be deemed incorrect. However, should the
                      incorrect answer be carried over correctly, the marker has to re-
                      calculate the values, using the incorrect answer from the first
                      calculation. If correctly used, the candidate should receive the full
                      marks for subsequent calculations.

3.        This memorandum is only a guide with model answers. Alternative
          interpretations must be considered and marked on merit. However, this
          principle should be applied consistently throughout the marking session at
          ALL marking centres.

Copyright reserved                                                              Please turn over

### Page 3

Downloaded from hlayiso.com
Electrical Technology: Power Systems             3                        DBE/2022
                                       SC/NSC – Marking Guidelines

QUESTION 1: MULTIPLE-CHOICE QUESTIONS

1.1       C                                                                        (1)

1.2       A                                                                        (1)

1.3       C                                                                        (1)

1.4       B                                                                        (1)

1.5       B                                                                        (1)

1.6       B                                                                        (1)

1.7       D                                                                        (1)

1.8       A                                                                        (1)

1.9       C                                                                        (1)

1.10      D                                                                        (1)

1.11      C                                                                        (1)

1.12      A                                                                        (1)

1.13      B                                                                        (1)

1.14      B                                                                        (1)

1.15      D                                                                        (1)
                                                                                    [15]

Copyright reserved                                                   Please turn over

### Page 4

Downloaded from hlayiso.com
Electrical Technology: Power Systems             4                                  DBE/2022
                                       SC/NSC – Marking Guidelines

QUESTION 2: OCCUPATIONAL HEALTH AND SAFETY

2.1       Machinery means any article or combination of articles assembled, arranged
          or connected  and which is used or intended to be used for converting any
          form of energy to performing work.                                                     (2)

2.2       Critical incident is an event that causes a grave or severe physical injury  to
          a person , threatening their safety.                                                   (2)

2.3          Sound the alarm system immediately. 
             Use the correct fire extinguisher if you were trained to 
             If there is a telephone nearby in a safe location, call your school secretary
              or principal to let them know of the situation.                                     (2)

2.4       Due to the pandemic the mask protects oneself and others from viral
          infections . Not using a mask will be an unsafe act because you are creating
          a life threatening unsafe act. 

                                                    OR

          Respirators and masks assist in preventing damage to the lungs when
          working in a contaminated area.                                                         (2)

2.5         Make use of a chemical waste company to remove or to dispose of
             chemicals. 
           Waste chemicals should NEVER be poured into toilets or down the drain
             as they can be harmful to the environment and the local sewerage
             system. 
           Only neutralised chemicals can be disposed of safely.
          NOTE: If the candidate mentions safety considerations with reference to the
          working environment, 1 mark will be awarded, but not personal protective
          equipment.                                                                              (2)
                                                                                                  [10]

Copyright reserved                                                             Please turn over

### Page 5

Downloaded from hlayiso.com
Electrical Technology: Power Systems                  5                               DBE/2022
                                            SC/NSC – Marking Guidelines

QUESTION 3: RLC CIRCUITS

3.1       A phasor diagram is a graphical representation  of a sinusoidal alternating
          current or voltage in an RLC circuit.                                                    (2)

3.2       3.2.1                                               
                               √        (         )
                              √        (                  )   
                            = 174,93 V                                                             (3)

          3.2.2       Lagging.  The circuit is inductive because the inductive voltage
                      (VL) is greater than the capacitive voltage (VC)  and the voltage
                      leads  the current by 90º                                                    (3)

3.3       3.3.1       IT  IR  (IL  IC )2
                                   2               
                                                   
                             4 2  (6  4)2
                             4,47 A                                                               (3)

          3.3.2                I                   
                      θ  Cos1 R
                               IT
                                        4          
                         Cos1
                                       4,47
                                                   
                         26,49 o                                                                   (3)

          3.3.3
                      Ic
                                

                                                                             

                                                                  IR
                                            Ø                               VT

                                                                      IX

                                                                       IT

                       IL      
                      NOTE: IC, IL and the angle is considered the primary marks. If the
                      rotation is omitted a mark will be allocated to VT being the
                      reference.                                                                    (4)

          3.3.4       The circuit is inductive because the inductive current is greater
                      than the capacitive current.                                                 (2)

Copyright reserved                                                               Please turn over

### Page 6

Downloaded from hlayiso.com
Electrical Technology: Power Systems             6                                 DBE/2022
                                       SC/NSC – Marking Guidelines

3.4       3.4.1       At resonance XL = XC = 150 Ω
                      Q
                            R                               
                           XL

                         
                           2200                             
                            150
                          14,67                                                                (3)

          3.4.2            f                                
                      BW  r
                           Q
                           2,387  103                      
                         
                             14,66
                          162,82 Hz                        
                                                                                                 (3)

          3.4.3                 1                           
                      XC 
                           2 π  f C
                                 1
                        C
                           2 π  f  X                     
                                        c
                                        1
                          
                            2  π  2,387  103  150
                           4,445 10 -7 F
                           444,51 nF                                                           (3)

          3.4.4       Selectivity is a measure  of how well a resonant circuit responds
                      to a range of frequencies  and excludes others.                           (2)

3.5       3.5.1       Capacitor- the current leads the voltage by 90o.                         (2)

          3.5.2       Pure resistor 
                      The voltage and current are in phase.                                     (2)
                                                                                                 [35]

Copyright reserved                                                            Please turn over

### Page 7

Downloaded from hlayiso.com
Electrical Technology: Power Systems             7                                    DBE/2022
                                       SC/NSC – Marking Guidelines

QUESTION 4: THREE-PHASE AC GENERATION

4.1       4.1.1       380 V to 415 V                                                               (1)

          4.1.2       L1 - red 
                      L2 – yellow / white 
                      L3 - blue                                                                    (3)

          4.1.3                                      L1 

                                                                            
                                                                      Rotation

                                                                  
                                                          120 º

                                  
                             L3                                        L2
                                                                            
                                                                                                    (5)

4.2       Generation  Power station
          Transmission 
          Distribution  to consumers                                                               (3)

4.3       4.3.1       Line voltage is measured between any two lines. 
                      (L1 & L2, L2 & L3 or L1 & L3)                                                 (1)

          4.3.2       Phase voltage is measured between any of the lines and
                      neutral. 
                      (L1 & N, L2 & N or L3 & N)                                                    (1)

4.4       Reactive power is the power needed in an AC system (transformer or motor)
          to set up  and maintain the magnetic field of that system  (transformer or
          motor).

          The following answer is provided in the textbook and will be accepted.

          Reactive Power is the power that is transferred backwards and forwards
          between the supply and the inductor or capacitor and performs no real work                (2)

Copyright reserved                                                               Please turn over

### Page 8

Downloaded from hlayiso.com
Electrical Technology: Power Systems             8                                DBE/2022
                                       SC/NSC – Marking Guidelines

4.5       4.5.1             = √3                       
                                                       
                            = √3 230
                                                       
                            = 398 37                                                            (3)

          4.5.2           = √3                         
                          = √3 398 37      35          
                                                       
                          = 24149 90
                          = 24 15                                                               (3)

          4.5.3             = √3                                     
                            = √3 398 37      35        18            
                                                                     
                            = 7462 73
                            = 7 46                                                              (3)

          4.5.4       P        √3                                    
                            = √3 398 37      35        18            
                                                                     
                            = 22967 91
                            = 22 97                                                             (3)

4.6       4.6.1       (a)    Coil 1 – current coil                                             (1)

                      (b)    Coil 2 – voltage coil                                             (1)

          4.6.2       It can be used on balanced and unbalanced loads. 
                      It can be used on star or delta systems. 
                      The power factor can also be determined.                                  (2)

          4.6.3             = 1    2                   
                            = 960 870                  
                            = 1830                                                             (3)

                      The following formula and method is used in the textbook and will
                      also be accepted
                      PT = W 1 +W 2
                          = 960 +870
                          = 1830 W
                                                                                                [35]

Copyright reserved                                                           Please turn over

### Page 9

Downloaded from hlayiso.com
Electrical Technology: Power Systems             9                             DBE/2022
                                       SC/NSC – Marking Guidelines

QUESTION 5: THREE-PHASE TRANSFORMERS

5.1       Core-type 
          Shell type                                                                        (2)

5.2       Dielectric oil is a non-conductor of electricity and provides electrical
          insulation between the case and the windings. 
          It provides cooling to the transformer.                                           (2)

5.3       The Buchholz relay is placed in-line between the conservator  and the
          transformer housing.                                                              (2)

5.4

          NOTE: 1 mark for each delta connection on the primary side
                1 mark for the common neutral connection on the secondary side
                1 mark for indicating the three supply lines on the primary side
                1 mark for indicating the three load lines on the secondary side
                1 mark for indicating that it is a step down transformer by
                the turns ratio or drawing less turns on the secondary side.                 (7)

5.5       5.5.1       =                                 
                      = 10 000     08                   
                      = 8 000                                                               (3)

          5.5.2                                         
                      =                   100
                             8 000                      
                      =                         100
                        8 000 300        50
                      = 95 8                                                                (3)

Copyright reserved                                                        Please turn over

### Page 10

Downloaded from hlayiso.com
Electrical Technology: Power Systems              10                       DBE/2022
                                        SC/NSC – Marking Guidelines

5.6       5.6.1       (        ) = √3                    
                                  = √3 6000     2        
                                  = 20 784 61            
                                  = 20 78                                                (3)

          5.6.2                                          
                              =
                                  18 000                 
                              =
                                20 784 61
                              = 0 87                                                    (3)

          5.6.3      For Delta VL = Vph                  
                                  = 6 000 V                                             (2)

          5.6.4               1             1       1
                          =                     =
                              2             2       2

                     therefore
                                   1
                          =                              
                                   2

                              6 000
                          =                              
                               240
                          = 25
                          = 25:1                         
                                                                                         (3)
                                                                                         [30]

Copyright reserved                                                    Please turn over

### Page 11

Downloaded from hlayiso.com
Electrical Technology: Power Systems              11                               DBE/2022
                                        SC/NSC – Marking Guidelines

QUESTION 6: THREE-PHASE MOTORS AND STARTERS

6.1       Continuity test between the ends of each coil. 
          Continuity test between the frame of the motor and earth.                             (2)

6.2       Cogging is the tendency of rotor rod to remain stuck under a stator tooth 
          due to the direct magnetic attraction between the two.                                (2)

6.3       Less maintenance  because of the absence of slip rings and brushes.
          Explosion proof  because of the absence of brushes and slip rings that
          cause sparking.                                                                        (2)

6.4       Cranes 
          Conveyor belts                                                                        (2)

6.5       A - Pull-up torque 
          B - Breakdown torque 
          C - Full load torque                                                                  (3)

6.6       Synchronous speed is the speed at which the magnetic field in the stator
          rotates. 
          Rotor speed is the speed at which the rotor rotates in the attempt to reach the
          synchronous speed.                                                                    (2)

6.7       6.7.1                60                        
                           =
                           60 50                         
                         =
                              3
                         = 1 000                                                                (3)

          6.7.2                                          
                               =           100
                                    1 000 950            
                               =                 100
                                  1 000
                               =5                                                               (3)

6.8       6.8.1       Iron losses 
                      Mechanical losses                                                         (2)

          6.8.2                                          
                       =                  100
                          5 000 600                      
                        =           100
                             5 000
                        = 88                                                                    (3)

Copyright reserved                                                            Please turn over

### Page 12

Downloaded from hlayiso.com
Electrical Technology: Power Systems               12                             DBE/2022
                                         SC/NSC – Marking Guidelines

          6.8.3
                       =          100                     

                           =
                                100
                               5 000     88
                           =                              
                                   100
                               = 4 400
                               = 4 40
                                                                                               (3)

6.9       6.9.1       Timer                                                                    (1)

          6.9.2       Each overload unit monitors the current drawn  by each motor
                      independently.                                                           (2)

          6.9.3       The MC1N/O1 auxiliary contact (Hold contact) connected in parallel
                      with the start button is omitted.                                        (1)

          6.9.4       The moment the start button is released MC1 will de-energise, 
                      opening MC1N/O2,  disconnecting the parallel section of
                      the control circuit,  disabling timer T1,  thus MC2 will not be
                      energised.                                                                (4)
                                                                                                [35]

Copyright reserved                                                           Please turn over

### Page 13

Downloaded from hlayiso.com
Electrical Technology: Power Systems             13                                 DBE/2022
                                       SC/NSC – Marking Guidelines

QUESTION 7: PROGRAMMABLE LOGIC CONTROLLERS (PLCs)

7.1       The function of the central processing unit is to execute the instructions  as
          per the inputs  and provide the outputs.                                              (3)

7.2       Reduced cost 
          Reduced space
          Flexibility
          Simplicity.                                                                             (1)

7.3       7.3.1       The purpose of the timer function is to activate or deactivate a
                      device  after or before a pre-set interval of time. 
                                                       OR
                      The purpose of the timer function is to run an operation for a
                      predetermined period of time and then deactivate it.                        (2)
          7.3.2       An ON delay timer's contact would not operate until a pre-set delay
                      time has passed, after it has first been energised  in the logic
                      sequence. 
                      An OFF-delay timer's contact will immediately operate  and remain
                      in this active state once energised. Its contacts will only deactivate
                      and open after the pre-set time has passed,  after it has been de-
                      energised.                                                                  (4)
7.4       7.4.1       Temperature sensor 
                      Proximity sensor 
                      Level sensor
                      Load sensor
                      Ultrasonic sensor
                      Pressure sensor                                                             (2)

          7.4.2       Light sensor is applied in:
                      Lighting systems controlled by a PLC 
                      A sprinkler system controlled by a PLC to only operate at night.
                      Photoelectric sensor counting items on a conveyor belt system.              (2)

7.5        L   

                                                                              MC
                     O/L         Stop           Start
                                                                            

                                                  

                                          MC
                                          N/O
          NOTE: 1 mark for indicating the power rail or power supply
                1 mark for each correctly labelled symbol provided it makes logic sense
                 towards the operation of the circuit.                                            (6)

Copyright reserved                                                             Please turn over

### Page 14

Downloaded from hlayiso.com
Electrical Technology: Power Systems             14                                DBE/2022
                                  SC/NSC – Marking Guidelines

7.6       7.6.1       Regenerative energy is energy recovered from the motor  when it
                      slows down by converting mechanical energy to electrical energy 
                      which can be either used immediately or stored until needed.           (3)

          7.6.2       Regenerative braking methods may be used in:
                      Lifts 
                      Cranes 
                      Electrical locomotives or trains 
                      Battery powered electrical vehicle                                      (3)

7.7       7.7.1       AC-to DC-converter (rectifier) 
                      Filter                                                                 (2)

          7.7.2          Limit start-up current. 
                         Improvements in productivity. 
                         Improves energy usage by controlling the power that is fed into
                          the motor.
                         Reduce motor wear.
                         Better process control, such as speeding up or slowing down a
                          motor process depending on the type of production and
                          processes.
                         It can convert a fixed-frequency and fixed voltage to a variable
                          frequency and variable voltage.                                     (2)

7.8       7.8.1       Phase 1 – S1 and S4 
                      Phase 2 – S3 and S6 
                      Phase 3 – S5 and S2                                                    (3)

          7.8.2       The frequency to the motor is controlled by an AC controller that
                      switches the IGBTs on and off  at a certain frequency. 

                                                         OR

                      The frequency of the motor is controlled by an AC controller that
                      controls the tempo of switching the phases.                             (2)

          7.8.3          An AC controller switches S1 and S4 on and off  at a certain
                          frequency to create a train of positive pulses that imitates the
                          positive half cycle for phase 1. 
                         Thereafter it switches S2 and S3 on and off  at a certain
                          frequency to create a train of negative pulses that imitates the
                          negative half cycle for phase 1. 
                         The motor sees these positive and negative pulses as an AC
                          supply.                                                            (5)
                                                                                              [40]

                                                                                  TOTAL : 200

Copyright reserved

## Related documents

- [Electrical Technology May June 2022 (Digital) Afr](https://www.hlayiso.com/library/electrical-technology-may-june-2022-digital-afr/06607207-1ab5-4871-8074-c5e700e5a450) — Electrical Technology · QP · 2022 · Afr
- [Electrical Technology May June 2022 (Digital) Eng](https://www.hlayiso.com/library/electrical-technology-may-june-2022-digital-eng/d566fd2a-d854-43c7-887f-043f219d6078) — Electrical Technology · QP · 2022 · Eng
- [ELEC TECH GR12 MEMO SEPT2022 Power English](https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2022-power-english-1/1304f4fd-377a-40b4-8abd-4e3860f4fd0d) — Electrical Technology · Memo · 2022 · Eng
- [ELEC TECH GR12 MEMO SEPT2022 Digital English](https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2022-digital-english/d9f4d172-a252-4eb9-b51b-6936353fe4e6) — Electrical Technology · Memo · 2022 · Eng
- [ELEC TECH GR12 MEMO SEPT2022 Electronics English](https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2022-electronics-english/8e5f2a9b-1a0d-480e-8c17-93268b5cebfe) — Electrical Technology · Memo · 2022 · Eng
- [Electrical Technology May-June 2023 (Power Systems) MG Afr](https://www.hlayiso.com/library/electrical-technology-may-june-2023-power-systems-mg-afr/d3e896ed-f4d8-4c2a-9cac-f812d2b1a6b1) — Electrical Technology · Memo · 2023 · Afr

## More from Grade 12 Electrical Technology

- [Gr 12 Dig Elec ATP 2023-24](https://www.hlayiso.com/library/gr-12-dig-elec-atp-2023-24/8d3b2ee7-1d14-498d-a86b-d9fc34674531) — ATP
- [Electrical Technology (Power Systems) (English) June 2025 Question Paper](https://www.hlayiso.com/library/electrical-technology-power-systems-english-june-2025-question-paper/5422e67a-03a4-4202-ba9b-1b9ec9872537) — QP · 2025 · Eng
- [ELEC TECH GR12 MEMO SEPT2024 Digital English](https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2024-digital-english/cb603860-b00d-40c2-a36b-aa5e97b7d1e5) — Memo · 2024 · Eng
- [ELEC TECH GR12 QP SEPT2024 Electronics Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-electronics-afrikaans/6fc3719e-6eab-469e-baf1-ca1645c8ebad) — QP · 2024 · Afr
- [ELEC TECH GR12 QP SEPT2024 Power Systems Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-power-systems-afrikaans/928e510b-68c2-4670-a7c7-fe20b388befb) — QP · 2024 · Afr
- [ELEC TECH GR12 QP SEPT2024 Digital English](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-digital-english/9fcfef2b-6d5e-4601-853a-24a2a3993617) — QP · 2024 · Eng

## Collection

- [Grade 12 past papers](https://www.hlayiso.com/grade-12/past-papers)

---

Hlayiso: free CAPS and IEB past papers, memos, notes and study guides for South African learners. When citing, link the page URL above, not a PDF or /api/ URL.