# Electrical Technology Grade 12 NSC November 2021 Memo (Eng)

> Grade 12 Electrical Technology memorandum from the NSC November Exam 2021 (English), 15 pages. Read online or download the free PDF.

- Page: https://www.hlayiso.com/library/electrical-technology-nov-2021-power-systems-mg-eng/defea319-14d0-4221-a962-98f3400cb70c
- Updated: 2026-10-29
- Subject: Electrical Technology
- Grade: Grade 12
- Document type: Memorandum
- Year: 2021
- Exam period: NSC November Exam
- Curriculum: CAPS
- Pages: 15

Breadcrumbs: [Home](https://www.hlayiso.com/) › [Library](https://www.hlayiso.com/library) › [Grade 12](https://www.hlayiso.com/library/grade-12) › [Electrical Technology](https://www.hlayiso.com/library/grade-12/electrical-technology) › [Electrical Technology Grade 12 NSC November 2021 Memo (Eng)](https://www.hlayiso.com/library/electrical-technology-nov-2021-power-systems-mg-eng/defea319-14d0-4221-a962-98f3400cb70c)

## About this document

Electrical Technology · Grade 12 · NSC November Exam · 2021. Memorandum. Read online or download the PDF.

Read it free online on the page above; download the PDF from there.

## Document text

Text extracted from the PDF. Layout, diagrams and tables may not survive extraction.

### Page 1

Downloaded from hlayiso.com

                                     NATIONAL
                                SENIOR CERTIFICATE

                                        GRADE 12

                     ELECTRICAL TECHNOLOGY: POWER SYSTEMS

                                    NOVEMBER 2021

                                 MARKING GUIDELINES

MARKS: 200

                      These marking guidelines consist of 15 pages.

Copyright reserved                                                    Please turn over

### Page 2

Downloaded from hlayiso.com
Electrical Technology: Power Systems              2                       DBE/November 2021
                                       NSC – Marking Guidelines

INSTRUCTIONS TO THE MARKERS

1.        All questions with multiple answers imply that any relevant, acceptable
          answer should be considered.

2.        Calculations:

          2.1        All calculations must show the formulae.

          2.2        Substitution of values must be done correctly.

          2.3        All answers MUST contain the correct unit to be considered.

          2.4        Alternative methods must be considered, provided that the correct
                     answer is obtained.

          2.5        Where an incorrect answer could be carried over to the next step,
                     the first answer will be deemed incorrect. However, should the
                     incorrect answer be carried over correctly, the marker has to re-
                     calculate the values, using the incorrect answer from the first
                     calculation. If correctly used, the candidate should receive the full
                     marks for subsequent calculations.

3.        These marking guidelines are only a guide with model answers. Alternative
          interpretations must be considered and marked on merit. However, this
          principle should be applied consistently throughout the marking session at
          ALL marking centres.

Copyright reserved                                                            Please turn over

### Page 3

Downloaded from hlayiso.com
Electrical Technology: Power Systems              3               DBE/November 2021
                                       NSC – Marking Guidelines

QUESTION 1: MULTIPLE-CHOICE QUESTION

1.1       C                                                                             (1)

1.2       B                                                                             (1)

1.3       A                                                                             (1)

1.4       D                                                                             (1)

1.5       A                                                                             (1)

1.6       C                                                                             (1)

1.7       B                                                                             (1)

1.8       D                                                                             (1)

1.9       A                                                                             (1)

1.10      D                                                                             (1)

1.11      B                                                                             (1)

1.12      C                                                                             (1)

1.13      D                                                                             (1)

1.14      A                                                                             (1)

1.15      A                                                                             (1)
                                                                                         [15]

Copyright reserved                                                    Please turn over

### Page 4

Downloaded from hlayiso.com
Electrical Technology: Power Systems              4                    DBE/November 2021
                                       NSC – Marking Guidelines

QUESTION 2: OCCUPATIONAL HEALTH AND SAFETY

2.1          To identify and communicate potential hazards 
             To identify potential major incidents  at the workplace to the
              employer.
                                                  OR
             To review the effectiveness of health and safety measures.
             To investigate complaints by employees relating to health and safety at
              work.                                                                           (2)

2.2          Your right to earn a living wage.
             Your right to work for reasonable hours.
             Your right to belong to a trade union.                                          (2)

2.3       An unsafe act is an action committed by a person which may lead to an
          accident or unsafe condition and/or loss.
          An unsafe condition is a work related environmental condition which may lead
          to or contribute to an accident and/or loss.                                       (2)

2.4          High impact, low probability.
             High impact, high probability.
             Low impact, low probability.
             Low impact, high probability.
             Qualitative risk analysis.
             Quantitative risk analysis.                                                     (1)

2.5       'Danger' means anything that may cause injury to a person  or damage to
          property.                                                                         (2)

2.6          Use an apron  to protect your clothes from staining.
             Use protective glasses to protect your eyes.
             Use latex gloves to prevent skin irritation.
             Use a mask to reduce the risk of breathing fumes.                               (1)
                                                                                              [10]

Copyright reserved                                                         Please turn over

### Page 5

Downloaded from hlayiso.com
Electrical Technology: Power Systems              5                    DBE/November 2021
                                       NSC – Marking Guidelines

QUESTION 3: RLC CIRCUITS

3.1    Capacitive reactance is the opposition of the capacitor  to alternating current
       in an AC circuit.                                                                       (2)

3.2    There is a 90° phase shift between VL and IL  where IL lags VL by 90°.                 (1)

3.3    3.3.1
                                                   

                                                   

                                                                                              (3)

       3.3.2     Z  R 2  (XL  X C )2            
                                                   
                      602  (150  120)2
                      67,08 Ω                                                                (3)
       3.3.3                                       

                                                   

                                                                                              (3)

       3.3.4         R=Z
                     Phase angle = 0° 
                     VL = VC 
                     XL = XC
                     I is maximum                                                             (3)

3.4    3.4.1    800 Hz                                                                        (1)

       3.4.2    When the frequency increases from 200 Hz to 1600 Hz, the inductive
                reactance increases  and the capacitive reactance decreases.                 (2)

       3.4.3                                       
                                                   
                                                                                              (3)

Copyright reserved                                                          Please turn over

### Page 6

Downloaded from hlayiso.com
Electrical Technology: Power Systems                6               DBE/November 2021
                                         NSC – Marking Guidelines

       3.4.4
                 XC 
                         1                           
                        2fC
                          1
                     C
                        2fX C
                                  1
                        
                            2 (600)(1333)           
                         198,99  10-9 F
                                                     
                         198,99 nF
                                                                                           (3)

3.5    3.5.1     At resonance Z = R = 20 Ω
                 I T
                     V                                       
                     Z
                  
                    220                                      
                     20
                   11 A                                                                  (3)

       3.5.2         VL  I  X L                            
                         11 50                             
                         550 V                                                           (3)

       3.5.3
                     Q
                         XL                                  
                         R
                         50                                  
                       
                         20
                        2,5                                                              (3)
                 NOTE: XC over R is also accepted

       3.5.4     The phase angle would be zero because XL is equal to XC  and thus
                 VL = VC and out of phase with each other  this would cancel each
                 other, resulting in a power factor of 1.
                 R=Z
                 The circuit is at resonance                                               (2)
                                                                                           [35]

Copyright reserved                                                      Please turn over

### Page 7

Downloaded from hlayiso.com
Electrical Technology: Power Systems                  7                  DBE/November 2021
                                           NSC – Marking Guidelines

QUESTION 4: THREE-PHASE AC GENERATION

4.1    4.1.1    A - Generation 
                B - Transmission 
                C - Distribution                                                               (3)

       4.1.2                             
                     +V
                                R   Y      B

                     0
                                               t

                     -V
                             120o 120o 

                NOTE: The sequence of R,Y,B (VL1, VL2, VL3) must be correct to be
                      awarded full marks
                      The sequence given in the textbook as B,R,Y will be accepted
                      as correct                                                                (4)

       4.1.3    The voltage from the Generation process must be stepped up to reduce
                the current in the transmission lines  and therefore reducing the copper
                losses (I2R losses)  in the transmission lines.                                (2)

       4.1.4    Star,  because the end user needs to power both three-phase and
                single-phase equipment which is only possible with a star connection.          (2)

4.2    4.2.1               IL                                
                Iph 
                            3
                                                             
                           15
                      
                          3                                  
                       8,66 A                                                                  (3)

       4.2.2     S  3  VL  IL                             

                      3  380  15                          
                      9872,69 VA                            
                      9,87 kVA                                                                 (3)

       4.2.3     cos θ  0,9                                 
                          θ  cos1(0,9)                     
                            25,84O                          
                                                                                                (3)

Copyright reserved                                                           Please turn over

### Page 8

Downloaded from hlayiso.com
Electrical Technology: Power Systems              8                      DBE/November 2021
                                       NSC – Marking Guidelines

       4.2.4     Q  3  VL  IL  sinθ                  
                                                         
                      3  380  15  sin(25,84)
                      4303,11VA R                       
                      4,3 kVA R                                                                (3)

4.3    Less current drawn from the supply. 
       Reduced monthly electricity bill. 
       Reduced heat generated by equipment that will then last longer.
       Less maintenance of equipment.                                                           (2)

4.4    4.4.1     The meter shows a lagging power factor.                                       (1)

       4.4.2     The connected load is predominantly inductive.                                (1)

       4.4.3     By connecting capacitors in parallel with the load. 
                 By using synchronous motors.
                 By using phase advancers.                                                      (1)

4.5    4.5.1    PT  P1  P2                              
                      250  460                          
                                                          
                      710 W                                                                    (3)

       4.5.2    The phase angle. 
                Power factor.                                                                  (2)

       4.5.3    The meters can easily be connected to the lines. 
                The same connection is used for star or delta connected loads. 
                It is a more economical method of load measurement.                             (2)
                                                                                                [35]

Copyright reserved                                                           Please turn over

### Page 9

Downloaded from hlayiso.com
Electrical Technology: Power Systems              9                        DBE/November 2021
                                       NSC – Marking Guidelines

QUESTION 5: THREE-PHASE TRANSFORMERS

5.1       5.1.1      A - Oil conservator (Oil tank) 
                     B - Bushings (Isolators)                                                     (2)

          5.1.2      Oil Natural Air Forced 
                     Oil Forced Air Forced 
                     Oil Natural Air Natural (when the fan is off)
                     Oil Forced Water Forced                                                       (2)

          5.1.3      Inverse definite time relay 
                     Instantaneous overcurrent relay 
                     Balanced earth fault relay 
                     Buchholz relay
                     Restricted earth fault relay
                     Standby earth fault relay
                     Directional overcurrent relay                                                 (3)

          5.1.4         In a step down transformer the secondary has less windings than
                         the primary. The primary winding is connected to an alternating
                         voltage. 
                        This sets up an alternating emf in the primary windings and
                         alternating current flows. 
                        This alternating current creates an alternating magnetic field
                         which links with the secondary winding through the magnetic
                         core. (Faraday’s law) 
                        The alternating magnetic field cuts the secondary winding creating
                         a smaller alternating emf in it. 
                        Due to the reduced windings, the secondary voltage will be lower
                         than the primary voltage in accordance with the turns ratio and
                         voltage per winding in the primary and secondary windings of the
                         transformer.                                                             (5)

5.2       The windings are enclosed. 
          The axis of the shell type can be horizontal or vertical. 
          The core hides the major part of the windings.
          The core has five limbs.
          The coils are wound around the central section of the core.                              (2)

5.3       5.3.1      Delta star  step-down transformer                                            (1)

          5.3.2             VL2                            
                     VPH2 
                              3
                            7700                           
                          
                               3
                           4445,60 V                      
                           4,45 kV                                                                (3)

Copyright reserved                                                              Please turn over

### Page 10

Downloaded from hlayiso.com
Electrical Technology: Power Systems               10                   DBE/November 2021
                                         NSC – Marking Guidelines

          5.3.3               VPH1                           
                     TR 
                              VPH2
                             22 000                          
                          
                            4445,60
                           4,95 :1
                                                             
                           5 :1                                                               (3)

          5.3.4      S  3  VL2  IL2                       

                        3  7700  40                       
                        533471,65 VA
                                                             
                        533,47 kVA                                                            (3)

          5.3.5                          POUT                       
                     η                                     100
                          POUT  copper losses core losses
                              45 0000                               
                                             100
                        45 0000  1000  500
                       99,67 %                                                               (3)

          5.3.6                   P                          
                     Cosθ 
                                  S
                                  450000                     
                              
                                533471,65
                               0,84                                                          (3)
                                                                                               [30]

Copyright reserved                                                          Please turn over

### Page 11

Downloaded from hlayiso.com
Electrical Technology: Power Systems              11                       DBE/November 2021
                                        NSC – Marking Guidelines

QUESTION 6: THREE-PHASE MOTORS AND STARTERS

6.1       6.1.1      A – Terminal Box (Wiring Cover) 
                     B – Motor frame (Enclosure/Housing/Stator) 
                     C – Rotor                                                                    (3)

          6.1.2         Each of the stator windings is connected to a line of the three
                         phase supply in the terminal box. 
                        Each coil creates a magnetic field at alternate intervals (120o). 
                        The coils are spaced around the stator in such a way that it
                         creates the impression of a rotating magnetic field to the rotor. 
                                                          OR
                        When a three-phase supply is connected to a three-phase motor
                         stator a rotary magnetic field is established.
                        This is achieved by the three phases reaching maximum
                         strength 120o out of phase with each other.                               (3)

          6.1.3      Cranes. 
                     Conveyor belt systems. 
                     Lathes.
                     Drill presses.
                     Bench grinders.                                                               (2)

          6.1.4      Number of pole pairs. 
                     Frequency of the supply.                                                     (2)

6.2       6.2.1      This motor is connected in delta.                                            (1)

          6.2.2      Swop any TWO of the supply lines.                                            (1)

          6.2.3      Disconnect the supply lines from the motor. 
                     Remove the internal connecting plates.                                       (2)

6.3       6.3.1            f  60
                     ns                                     
                              p
                           50  60                           
                         
                               4
                          750 rpm                                                                (3)

          6.3.2               (ns  nr )                     
                     Slip                100
                                 ns
                                                             
                              (750  700)
                                          100
                                 750                         
                             6,67 %                                                               (3)

Copyright reserved                                                              Please turn over

### Page 12

Downloaded from hlayiso.com
Electrical Technology: Power Systems             12                        DBE/November 2021
                                       NSC – Marking Guidelines

          6.3.3      P  3  VL  IL  cosθ  η             
                                                   90       
                          3  380  6  0,85 
                                                  100
                          3021,04 W                        
                          3,02 kW
                                                                                                  (3)

6.4       6.4.1      MC1N/O1                                                                     (1)

          6.4.2      MC1N/O2 is a hold-out contact ensuring that MC2  can only be
                     energised if MC1 is energised.                                              (2)

          6.4.3      If either motor 1 or motor 2 is overloaded  the whole circuit will be
                     isolated. 
                                                        OR
                     If any one of the two overload relays are activated by either O/L1 or
                     O/L2 it will cut the power to the whole circuit.                             (2)

          6.4.4          When START 1 is pressed MC1 will energise. 
                         This will immediately close contacts MC1N/O1 (hold-in) and
                          MC1N/O2 (hold-out) and START 1 button can be released. 
                         Only after MC1N/O2 is closed you can press START 2. 
                         When START 2 is pressed, MC2 will energise closing contact
                          MC2N/O1 so that the start button can be released. 
                         When the STOP button is pressed, MC1 will de-energise
                          opening contact MC1N/O2 and de-energising MC2.                         (5)

          6.4.5      If contact MC2N/O1 is faulty and permanently closed, contactor MC2
                     will immediately energise  when MC1 is energised, without
                     pressing START button 2.                                                    (2)
                                                                                                  [35]

Copyright reserved                                                             Please turn over

### Page 13

Downloaded from hlayiso.com
Electrical Technology: Power Systems              13                        DBE/November 2021
                                        NSC – Marking Guidelines

QUESTION 7: PROGRAMMABLE LOGIC CONTROLLERS (PLCs)

7.1    7.1.1         Input module 
                     Output module 
                     Power supply                                                                  (2)

1      7.1.2            The CPU controls the PLC. 
                        Performs all calculations. 
                        It runs the PLC program. 
                        It processes all the input and output signals.                            (3)

       7.1.3         Transistor 
                     Relay                                                                         (1)

7.2    'Scan time' is the time  the PLC takes to complete one scan cycle.                        (2)

7.3    Software is the machine language  installed on a computer or written into a
       PLC’s control program  that instructs it to interact with its input and output
       hardware.                                                                                 (3)
7.4    7.4.1         A sensor is a device that detects a physical condition and
                     changes its electrical characteristics, such as resistance.                  (2)
       7.4.2         Light sensor. 
                     Level sensor. 
                     Proximity sensor.
                     Temperature sensor.                                                           (3)
       7.4.3         The overload sensor will continuously  (analogous) change its
                     characteristic resistance  as the load on it is altered or changed.
                     (Not in a stepped digital format)
                                                       OR
                     When connected to the analogue input on a PLC, parameters can be
                     determined within which the PLC will execute.                                 (3)

Copyright reserved                                                              Please turn over

### Page 14

Downloaded from hlayiso.com
Electrical Technology: Power Systems             14                         DBE/November 2021
                                       NSC – Marking Guidelines

7.5                  O/L       Stop       Start FWD
                     N/C
                              N/C          N/O            MC2 N/C      MC1   

                                          MC1 N/O
                                                    

                                          Start REV
                                             N/O            MC1 N/C      MC2 

                                           MC2 N/O
                                                    

       NOTE: O/L and Stop must both be in the same condition (either open or
             closed)                                                                                (10)
                                           OR

                        O/L                  Stop
                        N/C                  N/C                           MO1

                                          Start FWD                        MC1
                        MO1                                  MC2 N/C
                                             N/O

                                          MC1 N/O

                                          Start REV
                                             N/O             MC1 N/C       MC2

                                           MC2 N/O

Copyright reserved                                                               Please turn over

### Page 15

Downloaded from hlayiso.com
Electrical Technology: Power Systems             15                        DBE/November 2021
                                       NSC – Marking Guidelines

7.6    7.6.1         DC-to-AC Inverter.                                                       (1)

       7.6.2         Insulated Gate Bipolar Transistor (IGBT) 
                     Metal Oxide Semi-Conductor Field Effect Transistor (MOSFET)               (1)

       7.6.3         Improves energy usage. 
                     Reduces motor wear. 
                     Achieves variable motor speed control.                                    (2)

       7.6.4         Vector drives use a mathematical model of the drive-in software. By
                     measuring the current vectors  in relation to the applied voltage.
                     They are able to maintain a constant field at all frequencies  below
                     the line frequency.                                                      (3)

7.7    When the momentum of a load drives the motor, the motor changes into a
       generator  converting the mechanical energy into electrical energy  and in
       the process slowing the acceleration of the load.                                     (3)

7.8    Braking Resistor.                                                                     (1)
                                                                                               [40]

                                                                                 TOTAL:        200

Copyright reserved

## Related documents

- [Electrical Technology Nov 2021 (Electronics) Eng](https://www.hlayiso.com/library/electrical-technology-nov-2021-electronics-eng/fc61477e-f472-4e85-9460-13014dacc912) — Electrical Technology · QP · 2021 · Eng
- [Electrical Technology Nov 2021 (Electronics) Afr](https://www.hlayiso.com/library/electrical-technology-nov-2021-electronics-afr/b64b1972-e848-4315-914a-33ae2adfe7bd) — Electrical Technology · QP · 2021 · Afr
- [Electrical Technology Nov 2021 (Power Systems) Eng](https://www.hlayiso.com/library/electrical-technology-nov-2021-power-systems-eng/1f6d698d-cd31-4e9d-8b14-1f0cf8809640) — Electrical Technology · QP · 2021 · Eng
- [Electrical Technology Nov 2020 (Digital) Memo Eng](https://www.hlayiso.com/library/electrical-technology-nov-2020-digital-memo-eng/a1b08e2f-620d-401b-b392-473be3d00302) — Electrical Technology · Memo · 2020 · Eng
- [Electrical Technology Nov 2020 (Electronics) Memo Afr](https://www.hlayiso.com/library/electrical-technology-nov-2020-electronics-memo-afr/3a93ca21-b0ce-45ee-90c7-2d964cb448ce) — Electrical Technology · Memo · 2020 · Afr
- [Electrical Technology Nov 2020 (Power Systems) Memo Eng](https://www.hlayiso.com/library/electrical-technology-nov-2020-power-systems-memo-eng/88b14e44-b06a-4447-9c35-edf475d6c7c0) — Electrical Technology · Memo · 2020 · Eng

## More from Grade 12 Electrical Technology

- [Gr 12 Dig Elec ATP 2023-24](https://www.hlayiso.com/library/gr-12-dig-elec-atp-2023-24/8d3b2ee7-1d14-498d-a86b-d9fc34674531) — ATP
- [Electrical Technology (Power Systems) (English) June 2025 Question Paper](https://www.hlayiso.com/library/electrical-technology-power-systems-english-june-2025-question-paper/5422e67a-03a4-4202-ba9b-1b9ec9872537) — QP · 2025 · Eng
- [ELEC TECH GR12 MEMO SEPT2024 Digital English](https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2024-digital-english/cb603860-b00d-40c2-a36b-aa5e97b7d1e5) — Memo · 2024 · Eng
- [ELEC TECH GR12 QP SEPT2024 Electronics Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-electronics-afrikaans/6fc3719e-6eab-469e-baf1-ca1645c8ebad) — QP · 2024 · Afr
- [ELEC TECH GR12 QP SEPT2024 Power Systems Afrikaans](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-power-systems-afrikaans/928e510b-68c2-4670-a7c7-fe20b388befb) — QP · 2024 · Afr
- [ELEC TECH GR12 QP SEPT2024 Digital English](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-digital-english/9fcfef2b-6d5e-4601-853a-24a2a3993617) — QP · 2024 · Eng

## Collection

- [Grade 12 past papers](https://www.hlayiso.com/grade-12/past-papers)

---

Hlayiso: free CAPS and IEB past papers, memos, notes and study guides for South African learners. When citing, link the page URL above, not a PDF or /api/ URL.