# Electrical Technology Grade 12 NSC June 2024 Memo (English)

> Grade 12 Electrical Technology memorandum from the NSC June Exam 2024 (English), 15 pages. Read online or download the free PDF.

- Page: https://www.hlayiso.com/library/grade-12-electrical-technology-2024-nsc-june-exam-memorandum-english/adf56c51-9152-4a83-9d22-d5eef2167dc5
- Updated: 2026-09-28
- Subject: Electrical Technology
- Grade: Grade 12
- Language: English
- Document type: Memorandum
- Year: 2024
- Exam period: NSC June Exam
- Curriculum: CAPS
- Pages: 15

Breadcrumbs: [Home](https://www.hlayiso.com/) › [Library](https://www.hlayiso.com/library) › [Grade 12](https://www.hlayiso.com/library/grade-12) › [Electrical Technology](https://www.hlayiso.com/library/grade-12/electrical-technology) › [Electrical Technology Grade 12 NSC June 2024 Memo (English)](https://www.hlayiso.com/library/grade-12-electrical-technology-2024-nsc-june-exam-memorandum-english/adf56c51-9152-4a83-9d22-d5eef2167dc5)

## About this document

Electrical Technology · Grade 12 · NSC June Exam · 2024 · English. Memorandum, 15 pages. Read online or download the PDF.

Read it free online on the page above; download the PDF from there.

## Document text

Text extracted from the PDF. Layout, diagrams and tables may not survive extraction.

### Page 1

SENIOR CERTIFICATE EXAMINATIONS/
         NATIONAL SENIOR CERTIFICATE EXAMINATIONS

            ELECTRICAL TECHNOLOGY: POWER SYSTEMS

                                  MAY/JUNE 2024

                             MARKING GUIDELINES

                                                                             MARKS: 200

                     These marking guidelines consist of 15 pages.

Copyright reserved                                                   Please turn over

### Page 2

Electrical Technology: Power Systems                 2                    DBE/May/June 2024
                                            SC/NSC Marking Guidelines

INSTRUCTIONS TO THE MARKERS

1.         All questions with multiple answers imply that any relevant, acceptable
           answer should be considered.

2.         Calculations:

           2.1        All calculations must show the formulae.

           2.2        Substitution of values must be done correctly.

           2.3        All answers MUST contain the correct unit to be considered.

           2.4        Alternative methods must be considered, provided that the correct
                      answer is obtained.

           2.5        Where an incorrect answer could be carried over to the next step,
                      the first answer will be deemed incorrect. However, should the
                      incorrect answer be carried over correctly, the marker has to re-
                      calculate the values, using the incorrect answer from the first
                      calculation. If correctly used, the candidate should receive the full
                      marks for subsequent calculations.

3.         This memorandum is only a guide with model answers. Alternative
           interpretations must be considered and marked on merit. However, this
           principle should be applied consistently throughout the marking session at
           ALL marking centres.

        Copyright reserved                                                       Please turn over

### Page 3

Electrical Technology: Power Systems             3                   DBE/May/June 2024
                                              SC/NSC – Marking Guidelines

QUESTION 1: MULTIPLE-CHOICE QUESTIONS

1.1       D✓                                                                                  (1)

1.2       C✓                                                                                  (1)

1.3       C✓                                                                                  (1)

1.4       B✓                                                                                  (1)

1.5       D✓                                                                                  (1)

1.6       C✓                                                                                  (1)

1.7       A✓                                                                                  (1)

1.8       C✓                                                                                  (1)

1.9       D✓                                                                                  (1)

1.10      D✓                                                                                  (1)

1.11      A✓                                                                                  (1)

1.12      B✓                                                                                  (1)

1.13      D✓                                                                                  (1)

1.14      B✓                                                                                  (1)

1.15      C✓                                                                                  (1)
                                                                                              [15]

       Copyright reserved                                                      Please turn over

### Page 4

Electrical Technology: Power Systems             4                     DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

QUESTION 2: OCCUPATIONAL HEALTH AND SAFETY

2.1    Failure to use safety equipment.✓
       Tampering or misusing safety equipment. ✓
       Wilfully or recklessly operating machinery that threatens the health of the user.        (2)

2.2    Furnishing false information to the inspector. ✓
       Failure to comply with any performance or safety requirements made by the
       inspector. ✓
       Obstructing the inspector in the performance of his/her duties.                          (2)

2.3    Manufacturers who design and manufacture articles for the use at work must
       ensure that the product is safe to use ✓ and the information and processes for
       the use of the artefact manufactured is clear ✓ and would assist with safe
       operation of the artefact.                                                               (2)

2.4    It is an event that is not expected ✓ that would not require calling for outside
       emergency assistance. ✓                                                                  (2)

2.5    It can cause the heart muscle to contract ✓ so strongly leading to heart
       failure. ✓                                                                               (2)
                                                                                                [10]

      Copyright reserved                                                         Please turn over

### Page 5

Electrical Technology: Power Systems             5                      DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

QUESTION 3: RLC CIRCUITS

3.1       Reactance is the opposition offered to the flow of alternating current✓ by an
          inductor or capacitor ✓ in an AC circuit.
          Reactance is the ratio of voltage to current in an alternating circuit when
          voltage and current are not in phase.                                                  (2)

3.2       3.2.1      The circuit is predominantly capacitive ✓ because VC is greater than
                     V L. ✓                                                                      (2)

          3.2.2                                              ✓
                     𝑉𝑇 = √𝑉𝑅 2 + (𝑉𝐶 − 𝑉𝐿 )2

                           = √182 + (15 − 10)2               ✓
                           = 18,68 𝑉                         ✓
                                                                                                 (3)

          3.2.3                   𝑉𝑅                         ✓
                     𝐶𝑜𝑠𝜃 =
                                  𝑉𝑇
                                  18                         ✓
                     𝜃 = 𝐶𝑜𝑠 −1 (     )
                                 18,68
                                                             ✓
                       = 15,51°
                                                                                                 (3)

          3.2.4

                             VL
                                                         ✓
                                                    VR
                                         θ
                        ✓
                     (VC -VL)                                Rotation
                                                    VT ✓
                             VC

                     NOTE: If IT is indicated in the place of VR, a mark will be awarded.
                           If the phase angle is correctly indicated in the place of
                            (VC-VL) a mark will be awarded.                                      (3)

          3.2.5      The supply current (IT) and the voltage across the resistance (VR)
                     are always in-phase ✓ and VR is leading VT, ✓ therefore it is safe to
                     assume that IT is also leading VT by the same angle.
                     In a capacitive circuit the supply current will always lead the supply
                     voltage. (1 mark)                                                           (2)

      Copyright reserved                                                          Please turn over

### Page 6

Electrical Technology: Power Systems             6                   DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

3.3       3.3.1             𝑉𝑇
                     𝐼𝐿 =                                   ✓
                            𝑋𝐿
                             230                            ✓
                       =
                            62,83
                       = 3,66 𝐴                             ✓
                                                                                             (3)

          3.3.2                                             ✓
                     𝐼𝑇 = √𝐼𝑅 2 + (𝐼𝐿 − 𝐼𝐶 )2
                       = √1,152 + (3,66 − 1,59)2            ✓
                                                            ✓
                       = 2,37 𝐴                                                              (3)

          3.3.3      𝐶𝑜𝑠𝜃 = 𝑝𝑓
                                 𝐼𝑅
                     𝐶𝑜𝑠𝜃 =                                 ✓
                                 𝐼𝑇
                                 1,15                       ✓
                             =
                                 2,37
                                                            ✓
                             = 0,49
                                                                                             (3)

          3.3.4      At resonance XL=XC, Therefore          ✓
                             1
                     𝑋𝐶 =                                   ✓
                           2𝜋𝑓𝐶
                              1
                     𝐶=
                            2𝜋𝑓𝑋𝐶
                                  1
                       =                                    ✓
                            2𝜋(50)(62,83)
                       = 50,66 µ𝐹                           ✓
                                                                                             (4)

3.4       3.4.1      A decrease in resistance increases the Q factor. ✓                      (1)

          3.4.2          𝑋𝐿                                 ✓
                     𝑄=
                          𝑅
                         2000
                       =                                    ✓
                          50
                                                            ✓
                       = 40
                                                                                             (3)

          3.4.3          𝑓1 + 𝑓2                            ✓
                     𝑓𝑟 =
                            2
                         1200 + 2100
                       =                                    ✓
                               2
                                                            ✓
                       = 1650 𝐻𝑧
                                                                                             (3)
                                                                                             [35]

      Copyright reserved                                                      Please turn over

### Page 7

Electrical Technology: Power Systems             7                   DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

QUESTION 4: THREE-PHASE AC GENERATION

4.1     4.1.1    22 kV ✓                                                                    (1)

        4.1.2    Phase 1 – Red ✓
                 Phase 2 – Yellow ✓
                 Phase 3 – Blue ✓

                 NOTE: R-Y-B is worth 1 mark                                                (3)

        4.1.3    The National grid is a network ✓ of over 25 000 km of high voltage
                 power lines to various bulk users. ✓
                                                    OR
                 The national grid is a network of power stations, high voltage power
                 lines and electricity infrastructure that allows electricity to be
                 generated, transmitted, and used across the country.                       (2)

        4.1.4    The transmission of electricity is done at such high voltages to
                 decrease the current flowing ✓ in the transmission lines and in the
                 process reducing the copper losses. ✓                                      (2)

        4.1.5    An industrial consumer makes use of three phase systems which
                 require a three-phase voltage ✓ of 400 volts whereas domestic
                 consumers make use of single-phase systems therefore requiring a
                 single-phase voltage ✓ of 230 volts.                                       (2)

4.2     A three-phase system is more economical. ✓
        A three-phase system can be connected in star or delta. ✓
        A three-phase system can supply three-phase and single-phase installations.
        Phase balancing can be done in three-phase systems.
        Three phase machines are self-starting eliminating switch gears.                    (2)

4.3     4.3.1    𝑆 = √3𝑉𝐿 𝐼𝐿                              ✓
                           𝑆
                 𝐼𝐿 =
                        √3𝑉𝐿
                        200 000                           ✓
                    =
                        √3(400)
                    = 288,68 𝐴                            ✓                                 (3)

        4.3.2    𝐼𝐿 = √3𝐼𝑃𝐻                               ✓
                           𝐼𝐿
                 𝐼𝑃𝐻 =
                           √3
                           288,68                         ✓
                     =
                               √3
                     = 166,67 𝐴                           ✓                                 (3)

      Copyright reserved                                                      Please turn over

### Page 8

Electrical Technology: Power Systems             8                   DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

        4.3.3            𝑃                                    ✓
                 𝐶𝑜𝑠𝜃 =
                         𝑆
                         180 000
                       =                                      ✓
                         200 000
                                                              ✓
                       = 0,9
                                                                                            (3)

        4.3.4              𝑃
                 𝐶𝑜𝑠𝜃 =
                           𝑆
                                 180 000
                     𝜃 = 𝐶𝑜𝑠 −1 (        )                ✓
                                 200 000
                                                          ✓
                     = 25,84°
                 𝑄 = √3𝑉𝐿 𝐼𝐿 𝑠𝑖𝑛𝜃                         ✓
                   = √3(400)(288,68)𝑠𝑖𝑛(25,84)            ✓
                   = 87173,38 𝑉𝐴𝑟                         ✓
                   = 87,17 𝑘𝑉𝐴𝑟                                                             (5)

4.4     4.4.1    At a central substation. ✓
                 Built into power consuming equipment.
                 Spread out over a distribution system.                                     (1)

        4.4.2    Reduced phase angle. ✓
                 Reduced reactive power.
                 Reduced apparent power.                                                    (1)

        4.4.3    The phase angle and apparent power decreased ✓ after power factor
                 correction. With the load and the supply voltage remaining the same,
                 the current drawn from the supply decreased ✓ because of the
                 improved power factor.                                                     (2)

4.5     Wattmeters are used with electrical devices to measure their power. ✓ Energy
        meters are used to measure electrical energy consumed over a period of
        time ✓ for billing or monitoring purposes.                                          (2)

4.6     𝑃2 = 𝑃𝑇 − 𝑃1                                  ✓
           = 3500 − 1300                              ✓
           = 2200 𝑊                                   ✓                                     (3)
                                                                                            [35]

      Copyright reserved                                                      Please turn over

### Page 9

Electrical Technology: Power Systems             9                      DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

QUESTION 5: THREE-PHASE TRANSFORMERS

5.1    5.1.1    Core type ✓ three-phase transformer.                                             (1)

       5.1.2    A shell-type transformer is less prone to magnetic stray loss ✓ than a
                core-type transformer.
                NOTE: Double magnetic circuit is captured in the comparison between
                shell-type and core-type transformers it will be accepted.                       (1)

       5.1.3    Star ✓- delta ✓ configuration                                                    (2)

       5.1.4    •   When an alternating voltage is applied to the primary windings, an
                    alternating flux is set up in the core ✓ which links with the secondary
                    windings, inducing an e.m.f of the same frequency. ✓
                •   When the load is connected to the secondary winding, a current will
                    flow through it. ✓
                •   Power is therefore transferred magnetically ✓ from the primary to the
                    secondary windings.                                                          (4)

5.2    5.2.1    An increase in the load will increase the secondary current ✓ resulting
                in more ✓ primary current drawn from the supply                                  (2)

       5.2.2    It provides electrical insulation between the windings and the case. ✓
                It also helps to provide cooling and prevents the formation of moisture
                on the windings.                                                                 (1)

       5.2.3    Hysteresis losses ✓
                Eddy current losses ✓                                                            (2)

       5.2.4    Air Natural: ✓ transformers are cooled by natural air ✓ flowing across
                the transformer windings.
                Air Forced: ✓ transformers are cooled by air being forced ✓ with a fan
                across the windings of a transformer.                                            (4)

       5.2.5    Single-phase transformer: Conductor size is bigger than for a three-
                phase transformer. ✓
                A three-phase transformer: Conductor size is 75% of that needed for
                single phase. ✓                                                                  (2)

5.3    5.3.1                    PT                        ✓
                 I L2 =
                           3  VL 2  Cos
                            300  10 3                    ✓
                     =
                           3  600  0,87
                                                          ✓
                     = 331,82 A                                                                  (3)

      Copyright reserved                                                          Please turn over

### Page 10

Electrical Technology: Power Systems             10                  DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

       5.3.2                IL                            ✓
                 I PH 2 =
                           3
                         331,83                           ✓
                       =
                             3
                       = 191,58 A                         ✓                                  (3)

       5.3.3                       𝑃                      ✓
                𝐼𝐿1 =
                        √3 × 𝑉𝐿1 𝐶𝑜𝑠𝜃
                                 300 000                  ✓
                   =
                       √3(8 000)(0,87)
                                                          ✓
                   = 24,89 𝐴                                                                 (3)

5.4    Buchholz relay ✓ (B)
       Restricted earth fault relay ✓ (REF)
       Directional overcurrent relay (DOC)
       Instantaneous overcurrent relay (HS)
       Balanced earth fault relay (BEF)
       Standby earth fault relay (SEF)                                                       (2)
                                                                                             [30]

      Copyright reserved                                                      Please turn over

### Page 11

Electrical Technology: Power Systems             11                   DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

QUESTION 6: THREE-PHASE MOTORS AND STARTERS

6.1       Rotor ✓
          Cooling Fan ✓
          Shaft                                                                                (2)

6.2       6.2.1      120 º ✓                                                                   (1)

          6.2.2      When a three-phase supply is connected to the stator, each coil pair
                     is connected to a different phase of the three-phase supply. ✓ This
                     causes current to flow in each coil at an angle of 120º. ✓ The coils
                     are also spaced 120º apart around the stator and the current flowing
                     through them will magnetise each coil at a different interval ✓ one
                     after the other at a frequency of 50 Hz creating a rotating magnetic
                     field in the process.✓                                                    (4)

          6.2.3      Because induction motors have no brushes on slip rings that cause
                     sparks. ✓                                                                 (1)

6.3       6.3.1                60 × 𝑓
                     𝑛𝑠 =                                   ✓
                                 𝑝
                               60 × 50                      ✓
                           =
                                  2
                           = 1500 𝑟/𝑚𝑖𝑛                     ✓
                                                                                               (3)

          6.3.2      𝑛𝑟 = 𝑛𝑠 (1 − %𝑠𝑙𝑖𝑝)                    ✓
                                      5
                        = 1500 (1 −      )                  ✓
                                     100
                        = 1425 𝑟/𝑚𝑖𝑛                        ✓                                  (3)

6.4       6.4.1                𝑃𝑖𝑛 − 𝑙𝑜𝑠𝑠𝑒𝑠
                     𝜂 =                    × 100
                                    𝑃𝑖𝑛                     ✓
                         11750 − 1750
                       =              × 100                 ✓
                            11750
                       = 85 %                               ✓                                  (3)

          6.4.2      𝑆 = √3𝑉𝐿 𝐼𝐿                            ✓
                       = √3(400)(20)                        ✓
                                                            ✓
                       = 13856,41 𝑉𝐴
                       = 13,86 𝑘𝑉𝐴                                                             (3)

      Copyright reserved                                                        Please turn over

### Page 12

Electrical Technology: Power Systems             12                   DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

          6.4.3              𝑃                              ✓
                     𝐶𝑜𝑠𝜃 =
                             𝑆
                               11750                        ✓
                           =
                             13856,41
                           = 0,85                           ✓                                  (3)

          6.4.4      𝑃𝑂𝑈𝑇 = √3𝑉𝐿 𝐼𝐿 𝐶𝑜𝑠𝜃𝜂             ✓
                                                 85
                           = √3(400)(20)(0,85) (    ) ✓
                                                100
                           = 10011,25 𝑊               ✓
                           = 10,01 𝑘𝑊                                                          (3)

6.5       6.5.1      Manual sequence starter. ✓
                     NOTE: Two DOL starters                                                    (1)

          6.5.2      MC1 is a contactor that energises and de-energises motor 1 ✓ in the
                     main (power) circuit whenever the start or stop button is pressed. ✓      (2)

          6.5.3      Each motor is protected by its own overload relay independently. ✓        (1)

          6.5.4      If motor 2 is overloaded and switched off by the overload, ✓ motor 1
                     will continue operating and feeding material onto conveyor 2. ✓ This
                     will cause a pile up of material on conveyor 2. ✓                         (3)

          6.5.5      By connecting a N/O contact of MC1 ✓ in the place of the temporary
                     connection ✓ MC2 will only be able to energise after MC1 is
                     energised.                                                                (2)
                                                                                               [35]

      Copyright reserved                                                        Please turn over

### Page 13

Electrical Technology: Power Systems             13                     DBE/May/June 2024
                                             SC/NSC – Marking Guidelines

QUESTION 7: PROGRAMMABLE LOGIC CONTROLLERS (PLCs)

7.1     It is easy to trace a circuit along its wires using a multi-meter. ✓
        It is easier to fault find as one could easily follow the wiring. ✓
        The circuit operation is easily ‘mapped out’. ✓
        Easier to install, maintain and fault find.
        All sensors, contacts and alarms are physically connected to a central panel via
        electrical wires.
        Hard wiring can conduct high currents to operate large machines.                            (3)

7.2     7.2.1

                                             A
                                             ✓                       Output

                                                                     ✓

                                             B
                                                 ✓
                                                                                                    (3)

        7.2.2     X =1✓
                  Y =0✓                                                                             (2)

7.3     7.3.1     Light sensor. ✓
                  Level sensor. ✓
                  Overload sensor. ✓
                  Temperature sensor.                                                               (3)

        7.3.2     A computing device (microprocessors, computers, and logic units) can
                  only interpret digital signals when processing the input. ✓ An analogue
                  signal, is highly affected by noise. ✓ this causes incorrect input
                  information limiting accuracy ✓ which results in an unpredictable
                  output.✓
                                                      OR
                  Analogue signals are sampled and converted to definitive digital steps
                  or values to eliminate or avoid any possible misinterpretations or fault
                  state that may arise from noise or interference that could be
                  superimposed on the input signal.                                                 (4)

7.4     The concept of latching makes it possible for circuit to be triggered 'on' ✓ and
        remain 'on' ✓ regardless of whether the activating trigger has been
        removed. ✓                                                                                  (3)

      Copyright reserved                                                         Please turn over

### Page 14

Electrical Technology: Power Systems                14                     DBE/May/June 2024
                                         SC/NSC Marking Guidelines

7.5     7.5.1    T is a timer that creates a time delay ✓ in the operation of the circuit
                 to energise MC2 a preset time after MC1. ✓                                  (2)
        7.5.2    MC1 must be energised. ✓
                 The timer must have timed through after being energised.    ✓               (2)
        7.5.3    The ON-delay timer’s contacts operates after a preset time has lapsed
                 when the timer is energised. ✓ An OFF-delay timer’s contacts
                 immediately operate when the timer is energised ✓ and open/closes
                 after a preset time has lapsed when the timer is de-energised. ✓            (3)
        7.5.4
                                             ✓            ✓                    ✓
                           STOP           O/L1       START                  MC1

                                                         ✓
                                                   MC1/NO1

                           MC1/NO2✓                                         T✓

                                                        ✓              ✓          ✓
                                                       O/L2          T/NO   MC2

                                                                                             (9)

                           STOP           O/L1       START                  MC1

                                                   MC1/NO1

                                      MC1/NO2                               T

                                                       O/L2          T/NO   MC2

      Copyright reserved

### Page 15

Electrical Technology: Power Systems                15                    DBE/May/June 2024
                                         SC/NSC Marking Guidelines

7.6     • AC induction motors speed depends on the frequency of the
          supply. ✓
        • A variable speed control receives the frequency, and its circuitry increases or
          decreases the output frequency to the motor. ✓
        • This varying of the frequency then increases or decreases the motor speed.✓       (3)

7.7     •  At start up the torque is at 200%.✓
        •  When the speed increases to the breakdown speed, the torque will
           increase. ✓
        • Thereafter torque will decrease as the motor speed increases further. ✓
        • The motor is accelerated from start to a region above the breakdown speed
           by the adjustable speed drive.
        NOTE: A verbal explanation of the curve without referring to the torque and
        corresponding speed only warrants 1 mark.                                           (3)
                                                                                            [40]

                                                                                 TOTAL : 200

      Copyright reserved

## Related documents

- [Electrical Technology May-June 2024 (Power Systems) Eng](https://www.hlayiso.com/library/grade-12-electrical-technology-2024-nsc-june-exam-question-paper-english/0d8d71f4-5725-40ea-9e29-a19e1c8a7867) — Electrical Technology · QP · 2024 · Eng
- [Electrical Technology May-June 2024 (Digital) Eng](https://www.hlayiso.com/library/grade-12-electrical-technology-2024-nsc-june-exam-question-paper-english/2b227e9b-0513-468e-8b1a-d4df808071cd) — Electrical Technology · QP · 2024 · Eng
- [ELEC TECH GR12 QP SEPT2024 Digital English](https://www.hlayiso.com/library/elec-tech-gr12-qp-sept2024-digital-english/9fcfef2b-6d5e-4601-853a-24a2a3993617) — Electrical Technology · QP · 2024 · Eng
- [ELEC TECH MEMO SEPT2023 Digital English](https://www.hlayiso.com/library/elec-tech-memo-sept2023-digital-english/1d2b04e7-c486-4f4e-9494-b0ccbcaf2ebb) — Electrical Technology · Memo · 2023 · Eng
- [ELEC TECH MEMO SEPT2023 Electronics English](https://www.hlayiso.com/library/elec-tech-memo-sept2023-electronics-english/5630ca3e-e352-4f96-81d0-64ec0103c0e9) — Electrical Technology · Memo · 2023 · Eng
- [ELEC TECH GR12 MEMO SEPT2022 Power English](https://www.hlayiso.com/library/elec-tech-gr12-memo-sept2022-power-english-1/1304f4fd-377a-40b4-8abd-4e3860f4fd0d) — Electrical Technology · Memo · 2022 · Eng

## More from Grade 12 Electrical Technology

- [Gr 12 Dig Elec ATP 2023-24](https://www.hlayiso.com/library/gr-12-dig-elec-atp-2023-24/8d3b2ee7-1d14-498d-a86b-d9fc34674531) — ATP
- [Electrical Technology (Power Systems) (English) June 2025 Question Paper](https://www.hlayiso.com/library/electrical-technology-power-systems-english-june-2025-question-paper/5422e67a-03a4-4202-ba9b-1b9ec9872537) — QP · 2025 · Eng
- [Electrical Technology Nov 2024 (Electronics) Eng](https://www.hlayiso.com/library/electrical-technology-nov-2024-electronics-eng/870e3d22-85e9-42bd-890f-3ef1fd3333cf) — QP · 2024 · Eng
- [Electrical Technology Nov 2024 (Electronics) Afr](https://www.hlayiso.com/library/electrical-technology-nov-2024-electronics-afr/98972424-ba56-4bbc-a319-fdfc1fec40f8) — QP · 2024 · Afr
- [Electrical Technology Nov 2024 (Power Systems) Afr](https://www.hlayiso.com/library/electrical-technology-nov-2024-power-systems-afr/5f2b4850-fffb-4024-8f24-d74bd8677a25) — QP · 2024 · Afr
- [ELEC TECH QP SEPT2023 Electronics English](https://www.hlayiso.com/library/elec-tech-qp-sept2023-electronics-english/867c1cd7-df12-484d-93b7-8812de59d0db) — QP · 2023 · Eng

## Collection

- [Grade 12 past papers](https://www.hlayiso.com/grade-12/past-papers)

---

Hlayiso: free CAPS and IEB past papers, memos, notes and study guides for South African learners. When citing, link the page URL above, not a PDF or /api/ URL.