Skip to content

Engineering Graphics and Design Grade 12 P1 2012 QP

Question paperEngineering Graphics and DesignGrade 12201212 pages

Grade 12 Engineering Graphics and Design Paper 1 question paper from the NSC Supplementary 2012, 12 pages. Read online or download the free PDF.

Free to read online, no sign-up needed

Answer online

Loading document…

Loading document…

NSC Supplementary 2012

Questions in this paper

Document textSearch extracted text and jump to a page.
Downloaded from hlayiso.com INSTRUKSIES EN INLIGTING 1. Hierdie vraestel bestaan uit VIER vrae. 2. Beantwoord AL die vrae. 3. ALLE tekene is in eerstehoekse ortografiese projeksie, tensy anders aangedui. 4. ALLE tekene moet voltooi word met instrumente, tensy anders aangedui. 5. ALLE antwoorde moet akkuraat en netjies geteken word. GRAAD 12 6. AL die vrae moet, soos voorgeskryf, op die VRAESTEL beantwoord word. 7. AL die bladsye moet weer in nommervolgorde vasgekram word, ongeag of die vraag beantwoord is. 8. Tydsbeplanning is noodsaaklik om al die vrae te voltooi. 9. Drukskryf jou eksamennommer in die blokkie voorsien op elke bladsy. 10. Enige besonderhede of afmetings wat nie gegee is nie, moet in goeie verhouding veronderstel word. NASIONALE SENIOR SERTIFIKAAT SLEGS VIR AMPTELIKE GEBRUIK VRAAG PUNTE BEHAAL ½ TEKEN GEMODEREER ½ TEKEN GRAAD 12 1 2 3 INGENIEURSGRAFIKA EN -ONTWERP V1 4 FEBRUARIE/MAART 2012 TOTAAL 2 0 0 2 0 0 PUNTE: 100 FINALE VERWERKTE PUNT NAGESIEN DEUR TYD: 3 uur ________ 100 VOLTOOI DIE VOLGENDE: Hierdie vraestel bestaan uit 6 bladsye. SENTRUMNOMMER SENTRUMNOMMER EKSAMENNOMMER EKSAMENNOMMER !GAUTENG! Kopiereg voorbehou Blaai om asseblief
Ingenieursgrafika en -ontwerp/V1t Downloaded fram hlayiso.com DBE/Feb.-Mrt. 2012 NOTA: Kontrakteurs moet alle afmetings en hoogtes op die terrein bevestig voordat daar met werk begin word. Argitekte moet onmiddellik in kennis gestel word van enige afwyki ings. VRAAG 1: ANALITIES (SIVIEL) Gegee: ‘n Gedetailleerde tekening van 'n snit deur die substruktuur van 'n nie-lasdraende muur, die terreinplan vir 'n nuwe kompleks met 10 troshuise, 'n titelpaneel en 'n tabel met vrae. Die tekene is nie volgens die aangetoonde skaal voorberei nie. 3 i Instruksies: 4 14. In die spasie hieronder, teken, in Voltooi die tabel hieronder deur die vrae, wat almal na die bygaande tekene en [ netjiese vryhand, die vooraansig titelpaneel verwys, netjies te beantwoord. [30] 5. en boaansig van die SABS 0143- ——————* = konvensie vir 'n STORT LET WEL: DIE ARSERINGSBESONDERHEDE VRAAG ANTWOORD IS UITGELAAT. FONDASIE 6——_|_+ VOGWEERLAAG GEDETAILLEERDE TEKENING VAN 'N SNIT DEUR DIE GRONDVLAK SUBSTRUKTUUR VAN 'N NIE-LASDRAENDE MUUR BINNEMUUR Met verwysing na die gedetailleerde tekening van 'n snit deur 4, | dle substruktuur van 'n nie-lasdraende muur, verbind dle BETONBLAD 10 nommer op die tekening met die korrekte komponent in die GEKOMPAKTEERDE kolom regs van hierdie vraag. HARDEPUIN ONGESTEURDE AARDE RYLAAN ERF 27 AFGEWERK D 72000 | VLAKLAAG ore I PLEISTER KEISTENE |\\ | _ _ — 5000 BL _ _ _ i 6 [ARGITEK SE HANDTEKENING VOLTOOIDE VLOERVLAK NI ERF 3 Se ee tT Ng ° ALIENT SE HANDTEKENING 2. | Watis die verwysingskode van die tekening? 1 ' \ ! s 3. | Wie was verantwoordelik vir die druk van die terreinplan? 1 ! ONTSPANNINGS- nuwe, | | 4 | Wat is die afstand vanaf die boulyn na die palissadeheining? 1 ee 4 5 | in watter straat is die toegang tot die eiendom geleé? 1 y 6 | Wat word deur die kenmerk by 1 aangedui? 4 7 | Benoem die kenmerk by 2 1 I z HERSIENING | DATUM | BESKRYWING | 8 | Benoem die kenmerk by 3. 1 3 NEW WAVE g | Benoem die kenmerk by 4. 1 8 ARCHITECTS 10 | Benoem die kenmerk by 5. 1 a 5S ARGILERYLAAN z DURBAN 41 | Hoeveel geboue is op die erf? 4 2amHoe | & Tel: 031 303 8459 — - - - aaa Wat is die opperviakafwerking van die rylane in die ' SEDRUKDEUR DRUOATUN 12 1 PALISSADE- ! kompleks? VEILIGHEIDS- |_| ZAPPY DRUKKERS 2012-01-10 HEINING [1H TERENTTEL 413 | Bepaal die totale lengte van die metaalpalissade-velligheids- 3 1 TERREINPLAN heining in meter. Toon ALLE berekeninge. J In die spasie voorsien in die titelpaneel, teken, in nefjiese 8 ou 14 | vryhand, die vooraansig en boaansig van die SABS 0143 3 rH konvensie vir 'n stort. cnecncesod NUWE TROSBEHUISING VIR In die spasie hieronder, bepaal die totale opperviakte van 'n DIE DUBE TRUST OP ERF 3 15 | gnkele eenheid in vierkante meter ia 3 7 TE STRELITZIARYLAAN 58 TOTAAL La = — GINGINDLOVU. ANTWOORD 15 _ 40000 Y) (ELEKTRIESE \ ate sepriese tenks V7 (| Remwomer TEXENNGNOWNER Toon ALLE berekeninge. | TOEVOER TERREINPLAN *"\woet vo.ceNs 18 02 2 g KAAL 1: INGENIEUR- VERWVSNGSKODE GETEREN DER WAGESIEN DER | | ENKELE EENHEID | 3 Grensiences ) SKAAL 1: 200 SPESIFIKASIES GEBOU Q1Pt1-SUP-2012 | SANELE | LEBO oe EKSAMENNOMMER AB=CD WORD. ‘DATUM, SKAAL 74000 — IMM — e Kopiereg voorbehou mu il WU Blaai om asseblief
Downloaded fram hlayiso.com sche VRAAG 2: ONTWIKKELING Ingenieursgrafika en -ontwerpiV1 oe Gegee: Die vooraansig en boaansig van 'n gedeelte van ‘n kanaal wat 'n vierkant-na-vierkant-oorgangstuk met twee verbinding- stukke toon, Instruksies: 2.1. Teken, volgens skal 1 : 1, die gegewe vooraansig en boaansig van die gedeelte van die kanaal. 2.2 Ontwikkel die opperviak van SLEGS die oorgangstuk. Maak sy AB die naat. Toon ALLE nodige konstruksies en voulyne. [34] VERBINDINGSTUK OORGANGSTUK cm , VERBINDINGSTUK 65 0 ; Es) | H 50 b" SY AB IS DIE NAAT. ASSESSERINGSKRITERIA VOORAANSIG + 1 BOAANSIG: "4 2 |WARELENGTE-METODE | 10 3 | ONTWIKKELING 13, TOTAAL 34 EKSAMENNOMMER HI TREE a — Blaai om asseblief Kopiereg voorbehou
Ingenieursgrafika en -ontwerp/V1t Downloaded fram hlayiso.com DBE/Feb.-Mrt. 2012 oe VRAAG 3: PERSPEKTIEF Gegee: Twee aansigte van 'n kothuis en die inligting benodig om ‘n tweepuntperspektieftekening te teken. PV - Prentvlak HL - Horisonlyn GL - Grondlyn SP - Staanpunt Instruksies: Voltooi die perspektieftekening © Rig die tekenvel volgens die grondlyn (GL). * Toon ALLE nodige konstruksies. * Toon die muurdikte by die deur en die vensters. GEEN verborge besonderhede word verlang nie. [40] PV PV 1 opottt HL Lt HL ‘| fou PL! ' GL ee J GL ASSESSERINGSKRITERIA KONSTRUKSIES + VP'e 7 TRAPPE 7 MURE + DEUR + VENSTERS. 17 + DAK 9 SP TOTAAL 40 EKSAMENNOMMER OI — i Kopiereg voorbehou SU Blaai om asseblief
“enous eam Downloaded fram hlayiso.com secre usins VRAAG 4; SIVIELE TEKENING aes DAKKOMPONENTE 200 x 150 BETON- Gegee: [2] [75x50 KAPLATTE STEUNBALK * Die onvolledige noord-oos-aansig van 'n nuwe kothuis wat die mure, die posisie van die vensters, skuifdeur, die dak en 7 = [—— [228 x 20 FASSIEPLANK / notas toon 108 eee 3 *Die onvolledige vioerplan wat die mure, posisie van die W2 VENSTER 5 vensters, deure, toebehore en die elektriese toebehore toon [= | 114 x 38 MUURPLAAT SKUIFDEUR * Daknotas en 'n skematiese diagram van 'n dakkap VLOERVLAK *'n Diagram wat die kameraanduidings en vloerafwerkings GRONDLYN \ QL _ toon A TOEBEHORE * Die onvolledige fondasie- en muurbesonderhede ONVOLLEDIGE NOORD-OOS-AANSIG *'n Tabel met elektriese simbole 2 *'n Tabel met dakkomponente ® a *'n Tabel met toebehore TORREHORE = —isé«iR WAP F-—7 «'n Deur- en vensterskedule ; ; eee HORE eNIERDEUROPENINGE wi | Die onvolledige vioerplan van die nuwe kothuis, geteken D2 SKUIFDEUROPENING owe J ]| | volgens skaal 1 : 50, op bladsy 6 es W1,W2_ VENSTEROPENINGE Fa B BAD | Instruksies: WB — OPWASBAK 4 | Beantwoord hierdie vraag op bladsy 6. SSS sk TOILET *Deur die gegewe onvolledige vioerplan te gebruik, teken, BAD (B) we IVASBAK ! | kaal 1: 50 en di fikasies, die volgend x Bie INGEBOUDE KAS 3d volgens skaal 1: 50 en die spesifikasies, die volgende - aansigte van die nuwe kothuis: ELEKTRIESE TOEBEHORE = | 4.1 Die volledige vioerplan 7. DRIEPOOL-LIGSKAKELAAR ba | 4.2 Die noord-oos-aansig 2. ENKELPOOL-LIGSKAKELAARS ‘ . 3 PLAFONIIG jy | 4.3 'n Deursneeaansig volgens snyviak A-A 4.2.x 40 W FLUORESSEERBUISE Ww. I * ALLE tekene moet voldoen aan die riglyne en konvensies 5. SKAKELAARKRAGPUNT. URWAP Us DAKLYN, vervat in die SABS 0143. LET WEL: DIE PYL TOON DIE LIGVERBINDING ONVOLLEDIGE VLOERPLAN SPESIFIKASIES: MET DIE SKAKELAAR AAN. DIE VLOERPLAN Voeg die volgende kenmerke by die tekening: DAKNOTAS: * AL die deure en vensters. Toon die oopmaakrigting van die 875 DAKBEDEKKING 15 mm GOLFYSTER- skuifdeur. OPWASBAK (OWB) TOILET (Sk) WASBAK (WB) Poe? * 89 mm KAPLATTE @ * AL die toebehore soos aangedui deur die afkortings *AL die elektriese toebehore soos aangedui deur die ' . e 4114 x 38 mm DAKKAPPE OP 114 x 38 mm nommers 8 MUURPLATE | tS * AL die arseringsbesonderhede OM TE PAS DAKHELLING 30° MET 228 x 20 mm - - -——>. FASSIEPLANK AN BEIDE KANTE. | GELYK | cELYK PN DIE NOORD-OOS-AANSIG , - INGEBOUDE KAS (BIC) fk x 1 Toon die volgende kenmerke op die tekening: 4100 mm VIERKANTBAKGEUT 200 © Die buitemure SKEMATIESE DIAGRAM Di i i DEUR: EN VENSTERSKEDULE GIPSPLAFONGORD OP 4 STROKE VAN MATIESE DIAGR ia Die dakbesonderhede, insluitend die geut, fassieplank en 1000 2000 $B.» 38 rm PLAFONCATTE. EWEREDIG pL———=. | _reénwaterafvoerpyp : ; 500 500 GESPASIEER «Die venster- en skuifdeurbesonderhede, insluitend al die 4 oopmaakrigtings 8 alg DIE DEURSNEEAANSIG S 3 Toon die volgende kenmerke op die tekening: ~VENSTER UW! “| * Die volledige fondasie-, muur-, betonblad-, dak- en plafon- uw ——] VLOERAFWERKING besonderhede NOTA: 150 x 20 VESELSEMENTVENSTER- — VENSTER (W2) KOMBUIS: TEELS g * Die skuifdeurbesonderhede BANK ONDER ALLE VENSTERS BADKAMER KOMBUIS SITKAMER: — TEELS. al * AL die arseringbesonderhede OM TE PAS j QM TE PAS STOEP: TEELS : + rT 7 SITKAMER SLAAPKAMER: MAT Benoem die volgende: BADKAMER: EELS * Die noord-oos-aansig en die deursneeaansig PANEEL cusmomee a * Die kameraanduidings met vloerafwerkings ; el | MAAK NA | sre pancen _ sroep Se * Deur die korrekte afkortings te gebruik, benoem die volgende 3} ||RecTeRKant si) of ff LL. ET GRONDVLAK 5; ——} 33 kenmerke op die korrekte aansig: grondvlak en vogweerlaag oop S KAMERAANDUIDINGS MET 8 CO — at LET WEL: VLOERAFWERKINGS: 700 & « ALLE substruktuurarsering mag in vryhand geteken word. _ (96) SKUIFDEUR EN RAAM (02) DEUR EN RAAM (D) ONVOLLEDIGE FONDASIE- EN {96] i — z
“enous eam Downloaded fram hlayiso.com secre usine ASSESSERINGSKRITERIA VLOERPLAN 1 [evsxerre 5 2 [evextres 8 4 | toescHoRe 6 A 5 | Venstes 12 hv RWAP nT oO 7 6 | arsenic 6 1 2 | SUBTOTAAL | 37 | N | NOORD-00S-AANSIG | ‘ \ | 1 | Mure + vw 4 \ + GEUTe \ Ran & ! ; \ . | \ | 3 |ocur 9 Lon | N | 4 | BySKRIFTE 4 | | | ee +-—4 SUBTOTAAL 21 | _ | DEURSNEEAANSIG | | 4 | DAK 13 | | | \— Cc | 2 [Mowonses | 152 | | 3 | skUIFOEUR 1 | | | | 4 | syskriFTe 13 | J ee PL — | 5 | ARSERING 7 | YO | SUBTOTAAL 38 7 RWAP yet DAKLYN | TOTAAL 96 PLAN A EKSAMENNOMMER SKAAL 1 : 50 i —_
Downloaded from hlayiso.com INSTRUCTIONS AND INFORMATION 1. This question paper consists of FOUR questions. 2. Answer ALL the questions. 3. ALL drawings are in first-angle orthographic projection, unless otherwise stated. 4. ALL drawings must be completed using instruments, unless otherwise stated. 5. ALL answers must be drawn accurately and neatly. 6. ALL the questions must be answered on the QUESTION PAPER as instructed. 7. ALL the pages must be re-stapled in numerical sequence, irrespective of whether the question was attempted. 8. Time management is essential in order to complete all the questions. 9. Print your examination number in the block provided on every page. 10. Any details or dimensions not given must be assumed in good proportion. NATIONAL SENIOR CERTIFICATE FOR OFFICIAL USE ONLY QUESTION MARKS OBTAINED ½ SIGN MODERATED ½ SIGN GRADE 12 1 2 3 ENGINEERING GRAPHICS AND DESIGN P1 4 FEBRUARY/MARCH 2012 TOTAL 2 0 0 2 0 0 MARKS: 100 FINAL CONVERTED MARK CHECKED BY TIME: 3 hours _______ 100 COMPLETE THE FOLLOWING: This question paper consists of 6 pages. CENTRE NUMBER CENTRE NUMBER EXAMINATION NUMBER EXAMINATION NUMBER !GAUTENG! Copyright reserved Please turn over
Engineering Graphics and Design/P1 Downloaded from hlayiso.com DBE) Feb -Mar. 2012 NOTE: DRIVEWAYS FINISHED WITH COBBLE STONES, NEW INDIGENOUS: TREES ~ 2,3 m HIGH METAL PALISADE SECURITY THE HATCHING DETAIL HAS BEEN OMITTED, DETAILED DRAWING OF A SECTION THROUGH THE SUBSTRUCTURE OF A NON-LOAD-BEARING WALL STAND 27 | 72000 44000 — 5000 BL _ _ = STAND 3 e es 6 @' RECREATIONAL 121000 FENCE SECURITY CONTROL BUILDING ® 5000 BL. NOTE: Contractors must verify all dimensions and levels on site before commencing work. Architects to be immediately notified of any discrepancies. 14. In the space below, draw, in neat QUESTION 1: ANALYTICAL (CIVIL) Given: A detailed drawing of a section through the substructure of a non-load-bearing wall, the site plan for a new complex with 10 cluster homes, a title panel and a table of questions. The drawings have not been prepared to the indicated scale Instructions: Complete the table below by neatly answering the questions, which all refer to i NEE { EE /—-MAINROAD ~; (ELECTRICAL ‘SUPPLY ES95 BOUNDARY LENGTHS ‘AB=CD SITE PLAN SCALE 1 : 200 ALL SEPTIC TANKS TO BE BUILT TO ENGINEER'S ‘SPECIFICATIONS AD =BC freehand, the front view and top the accompanying drawings and title panel. 30) ying 9 view of the SABS 0143 convention for a SHOWER. QUESTIONS ANSWERS FOUNDATION DAMP-PROOF COURSE GROUND LEVEL . . INTERNAL WALL With reference to the detailed drawing of a section through 4, | the substructure of a non-load-bearing wall, link the number | CONCRETE SLAB 10 on the drawing with the correct component in the column to | GoMPACTED HARDCORE the right of this question. UNDISTURBED EARTH SCREED PLASTER FINISHED FLOOR LEVEL ARCHITECTS SIGNATURE 2 | Whatis the reference code for the drawing? 1 CLIENTS SIGNATURE — 3. | Who was responsible for the printing of the site plan? 1 4, | What is the distance from the building line to the palisade 4 fence? 5 | Inwhich road is the access to the property located? 1 6 | What does the feature at 1 indicate? 1 7 | Name the feature at 2. 1 REVISION pate | vescription | 8 |Name the feature at 3. 1 NEW WAVE 9 | Name the feature at 4 1 ARCHITECTS 10 | Name the feature at 5. 1 a AOUREAN 11 | How many buildings are on the stand? 1 Tel: 031 303 8459 12 | Whats the surface finish of the driveways in the complex? 1 PRINTED EY DATE OF PRINT ZAPPY PRINTERS 2012-01-10 43 | Determine the total length of the metal palisade security 3 DRAWING THLE fence line in metres. Show ALL calculations. SITE PLAN In the space provided in the title panel, draw, in neat 14 | freehand, the front view and top view of the SABS 0143 3 ROner convention for a shower. NEW CLUSTER HOMES FOR 45 | Inthe space below, determine the total area of a single unit in 3 DUBE TRUST ON STAND 3 AT Square metres 58 STRELITZIA ROAD ANSWER 15 GINGINDLOVU. Show ALL calculations. ¢—t0000__y TOTAL | 30 PROJECT NOWBER DRAWING NUMBER —— 18 002-8 2 REFERENCE CODE DRAWNBY [CHECKED BY 8) | SINGLE UNIT 3 Q1P1-SUP-2012 | SANELE | LEBO ° EXAMINATION NUMBER DATE SOA T4000 2011-02-30) 1: 200 EXAMINATION NUMBER [ 2 Copyright reserved Won Please tum over
DBE/Feb.-Mar. 2012 nn Downloaded from hlayiso.com QUESTION 2: DEVELOPMENT Given: The front view and top view of a portion of a duct showing a square-to-square transition piece with two connecting pieces. Instructions: 2.1 Draw, to scale 1: 1, the given front view and top view of the portion of the duct. 2.2 Develop the surface of the transition piece ONLY. Make edge AB the seam. Show ALL necessary construction and fold lines. [34] CONNECTING PIECE TRANSITION PIECE 65. FY CONNECTING PIECE EDGE AB IS THE SEAM ASSESSMENT CRITERIA FRONT VIEW + TOP VIEW 11 2) TRUE LENGTH METHOD | 10 3 | DEVELOPMENT 13, TOTAL 34 EXAMINATION NUMBER HI anamaTonnower [5 — Please tum over Copyright reserved
Engineering Graphics and Design/P1 Downloaded from hlayiso.com — QUESTION 3: PERSPECTIVE Given: Two views of a cottage and the information needed to draw a two-point perspective drawing PP ~ Picture plane HL - Horizon line GL - Ground line SP - Station point Instructions: Complete the perspective drawing * Align the drawing sheet with the ground line (GL) © Show ALL necessary construction © Show the wall thickness at the door and the windows. « NO hidden detail is required. [40] PP. PP opottt HL Lt HL + mee Pi | GL t---------| ! cc ASSESSMENT CRITERIA 4 | CONSTRUCTION + VPs 7 2 | STAIRS 7 3 WINDOWS 17 + 4 | ROOF 9 SP TOTAL 40 EXAMINATION NUMBER EXAMINATION NUMBER [4 Copyright reserved Won Please tum over
Engineering Graphics and Design/P1 Downloaded from hlayiso.com DBE/Feb.-Mar. 2012 ELECTRICAL ROOF COMPONENTS SXMEOES: 75 x 50 PURLINS [——1 |228 x 20 FASCIA BOARD. 114 x 38 WALL PLATE FIXTURES, 200 x 150 CONCRETE SUPPORT BEAM 100 x 100 BOX GUTTER 100 mm RWOP W2 WINDOW 2100 SLIDING DOOR FLOOR LEVEL GROUND LINE FIXTURES D1 HINGED DOOR OPENINGS 2 SLIDING DOOR OPENING W1, W2_ WINDOW OPENINGS B BATH s SINK we TOILET WB WASHBASIN BIC BUILT-IN CUPBOARD ELECTRICAL FIXTURES 400 a WASHBASIN (WB) 875 SINK (S) TOILET (WC) TO FIT BUILT-IN CUPBOARD (BIC) DOOR AND WINDOW SCHEDULE 4000 2000 500 500 1. THREE-POLE LIGHT SWITCH 2. SINGLE-POLE LIGHT SWITCHES, 3. CEILING LIGHT 4.2x 40 W FLUORESCENT TUBES. 5. SWITCH SOCKET OUTLETS, NOTE: THE ARROW SHOWS THE LIGHT CONNECTION TO THE SWITCH. ROOF NOTES: ROOF COVER 15 mm CORRUGATED IRON ON 75 x 50 mm PURLINS @ 1450 cle. 114 x 38 mm ROOF TRUSSES ON 114 x 38 mm WALL PLATES. ROOF PITCH 30° WITH 228 x 20 mm FASCIA BOARD ON BOTH ENDS. 100 mm SQUARE BOX GUTTER PLASTER CEILING BOARD ON 4 STRIPS OF 38 x 38 mm BRANDERING, EVENLY SPACED \ INCOMPLETE NORTH-EAST ELEVATION ROOF LINE INCOMPLETE FLOOR PLAN va EQUAL KITCHEN SLIDING DOOR AND FRAME (02) DOOR AND FRAME (D) LOUNGE =) FLOOR FINISH KITCHEN: — TILES LOUNGE: TILES PORCH: TILES BEDROOM: CARPET BATHROOM: TILES WINDOW (W1) NOTE: 150 x 20 FIBRE CEMENT WINDOW nD SILL UNDER ALL WINDOWS. (2) BATHROOM ' To FIT j Horn, PANEL BEDROOM 8} |] rowars || FIXED PANEL 8 SJ || THE RIGHT Ny ROOM DESIGNATIONS WITH FLOOR FINISH Copyright reserved Won t ben SCHEMATIC DIAGRAM OF A ROOF TRUSS: 200 pu = al ==, GROUND wey | 2B “ 700__| — INCOMPLETE FOUNDATION AND WALL DETAIL QUESTION 4: CIVIL DRAWING Given: The incomplete north-east elevation of a new cottage showing the walls, the position of the windows, sliding door, the roof and notes «The incomplete floor plan showing the walls, position of the windows, doors, fixtures and the electrical fixtures Roof notes and a schematic diagram of a roof truss * A diagram showing the room designations and floor finishes « The incomplete foundation and wall detail © A table of electrical symbols © A table of roof components © A table of fixtures * A door and window schedule The incomplete floor plan of the new cottage, drawn to scale 1: 50, on page 6 Instructions: * Answer this question on page 6. * Using the given incomplete floor plan, draw, to scale 1: 50 and to the specifications, the following views of the new cottage: 4.1 The complete floor plan 4.2 The north-east elevation 4.3 A sectional elevation on cutting plane A-A *ALL drawings must comply with the guidelines and conventions contained in the SABS 0143. SPECIFICATIONS: THE FLOOR PLAN Add the following features to the drawing: ALL doors and windows. Show the direction of opening for the sliding door. * ALL fixtures as indicated by the abbreviations * ALL the electrical fixtures as indicated by the numbers * ALL hatching detail THE NORTH-EAST ELEVATION Show the following features on the drawing: © The outside walls *The roof detail including the gutter, fascia board and rainwater downpipe The window and sliding door detail including all the directions of opening THE SECTIONAL ELEVATION Show the following features on the drawing: * The complete foundation, wall, slab, roof and ceiling detail * The sliding door detail * ALL hatching detail Label the following: * The north-east elevation and the sectional elevation * The room designations with floor finishes * Using the correct abbreviations, label the following features in the correct view: ground level and damp-proof course. NOTE: * ALL substructure hatching may be drawn in freehand. [96] Bl Please tum over
Engineering Graphics and Design/P1 Downloaded from hlayiso.com DBE/Feb.-Mar. 2012 | | \ RWDP | ; Se 1 [PS | ~ | \ | | \. | | | | | | | | | | }————-—-----~-------4 +—4 | | | S| | | | | _l C} | | | | i ee —4 | 1 U6 | | _/ RWDP | wot ROOF LUNE | __ PLAN SCALE 1 : 50 Copyright reserved Won ASSESSMENT CRITERIA FLOOR PLAN LABELS 5 ELECTRICAL 8 FITTINGS, 6 wnbows 12 HATCHING 6 SUBTOTAL 37 NORTH-EAST ELEVATION WALLS “FFL 4 Gurrer+ rior | 92 wnpons+ 9 LaseLs iH SUBTOTAL 21 SECTIONAL ELEVATION ROOF 13 WALLS + FLOOR 4 +rounoarions | 153 SLIONG DOOR 1 LABELS 1h HATCHING 7 ‘SUBTOTAL 38 TOTAL 96 EXAMINATION NUMBER EXAMINATION NUMBER

Study this subject

More from Grade 12 Engineering Graphics and Design

View all
Engineering Graphics and Design Grade 12 P1 2012 QP | Hlayiso