Downloaded from hlayiso.com INSTRUCTIONS AND INFORMATION This question paper consists of FOUR questions. Answer ALL the questions. ALL drawings are in first-angle orthographic projection, unless otherwise stated. ALL drawings must be prepared using pencil and instruments, unless otherwise Department: stated. Basic Education . ALL answers must be drawn accurately and neatly. « yy . ALL the questions must be answered on the QUESTION PAPER, as instructed. basic education BOND NO REPUBLIC OF SOUTH AFRICA ALL the pages, irrespective of whether the question was attempted or not, must be re-stapled in numerical sequence in the TOP LEFT-HAND CORNER ONLY. 8. Time management is essential in order to complete all the questions. 9. Print your examination number in the block provided on every page. 10. Any details or dimensions not given must be assumed in good proportion. SENIOR CERTIFICATE EXAMINATIONS/ NATIONAL SENIOR CERTIFICATE EXAMINATIONS RORLOFFIGIALUSIE ONLY QUESTION |} MARKS OBTAINED | 3 | SIGN MODERATED 3] SIGN RE-MARKING 2] sion 1 2 3 ENGINEERING GRAPHICS AND DESIGN P1 7i 2019 TOTAL 2/0/0 2/0/0 2/0/0 MARKS: 100 TIME: 3 hours FINAL CONVERTED MARK CHECKED BY 100 p77 ----------- 4 COMPLETE THE FOLLOWING: | | CENTRE NUMBER This question paper consists of 6 pages. | | sarcode be CENTRE NUMBER | | EXAMINATION NUMBER | | | | EXAMINATION NUMBER Copyright reserved Please turn over
Engineering Graphics and Design/P1 Downloaded fram hlayiso.com DBE/2019 LAND SURVEYOR'S CERTIFICATE OF STAND 108, SURVEYED ON 2017-08-31 BOUNDARY | CorNER HEIGHTS LENGTHS IN INMETRES METRES ‘AB = 22,36 ‘A= 1603 BC = 30 B= 1602, CD =20 C= 1598 DA=40 D = 1600 EVERGREEN PUBLIC PARK O % STAND 106 NEW 2m HIGH CONCRETE WALL 3 STAND 108 BUILT TO u = ENGINEER'S e| SPECIFICATIONS PROPOSED {NEW HOUSE| sp GENERAL NOTES: * NEW DRIVEWAY LAID ON WELL-COMPACTED HARDCORE WITH A 80 mm ASPHALT FINISH * SLOW RIVER IS A NON-PERENNIAL RIVER (DOES NOT FLOW THE ENTIRE YEAR) ‘SYMBOL LEGEND: + 2,5 m HIGH LAMP POSTS *PALM TREES, * DECIDUOUS TREES i _= * CONCRETE WALL PUBLIC PARKING SLOW RIVER ‘SERVITUDE PAVEMENT, a p (a) CONNECTION 4@ «&) 1,2m DEEP SITE PLAN SCALE 1 : 500 NOTE: Contractors. must verify all dimensions and levels on site before commencing work. Architects to be notified immediately of any discrepancies. ARCHITECT'S SIGNATURE CLIENT'S SIGNATURE QUESTION 1: ANALYTICAL (CIVIL) Given: The site plan of a proposed new house, a title panel and a table of questions. The drawing has not been prepared to the indicated scale. Instructions: Complete the table below by neatly answering the questions, which refer to the accompanying drawing, title panel and civil content. [30] ANSWER 20 In the space below, complete, in neat freehand and according to the SANS QUESTIONS ANSWERS 10143: a) The plan view of the ramp, with a 1 | Who checked the drawing? 1 gradient of 1 : 10 and the lowest F > point on the right 2 |Whatis the stand number of the proposed new house’ 1 b) The plan view of a sliding door | 3 | Whatis the project number? 1 between the given walls — 4 |How wide is Evergreen Drive in metres? 1 a) 5 | How deep is the municipal sewerage connection in metres? 1 6 | How many inspection eyes are on the drawing? 1 7 |How many deciduous trees are on STAND 108? 1 8 |How high are the lamp posts in millimetres? 1 D In what colour could proposed new work be indicated on a site 9 1 plan? va Z 10 | What does the abbreviation /C stand for? 1 Other than trees, what other natural feature is shown on the site 4 > 1 plan’ 412 |Name the feature at 1. 1 13 |Name the feature at 2. 1 14 | What does the number at 3 indicate? 1 2 2018/05/13 | MOVE LAMP POSTS | 45 |Name the feature at 4. 4 ‘ADD NEW , , 1 | 201810178 | gounoaay was | 4g | What is the shortest distance from wall ST on the proposed new ; house to Evergreen Drive in metres? REVISION DATE DESCRIPTION 47 | Which elevation of the proposed new house faces the entrance to A BAYERN the property? ARCHITECTS 48 |In the space below (ANSWER 18), determine the perimeter of the proposed new house in metres. 3 108 MUNICH DRIVE NEW GERMANY 49 | In the space below (ANSWER 19), determine the total area of STAND 108 in square metres. 3 ® 031 108 1080 In the space in the title panel (ANSWER 20), complete, in neat freehand and according to the 20 | SANS 10143: q PRNTED BY DATE OF PRINT: a) The plan view of the ramp, with a gradient of 1 : 10 and the lowest point on the right EXPRESS PRINT 2018-08-25 b) The plan view of the sliding door between the given walls DRAWING THLE SITE PLAN TOTAL | 30 PROECT ANSWER 18 9000 ‘ANSWER 19 Show ALL calculations. Rand ~ Show ALL calculations. PROPOSED NEW HOUSE FOR THOMAS ZONDO ON STAND 108, 2 EVERGREEN DRIVE, REEDSVILLE, 2080 s PROPOSED 8 $ [NEW HOUSE] ‘\ PRORCT NUMBER DRAWING NOWSER EY YG/-2018 CE 1-01-DV. =e DATE DRaan — [OntOXED, | SCALE 2018-01-13] DIANNE | VANESSA | 1: 500 sl EXAMINATION NONBER) REFERENCE CODE: ny X5-2018 EXAMINATION NUMBER [2| Copyright reserved Please tum over
Engineering Graphics and Design/P1 Downloaded fram hlayiso.com DBE/2019 oe Copyright reserved QUESTION 2: INTERPENETRATION AND DEVELOPMENT Given: * The incomplete front view and the top view of a hollow right square prism with a right cylindrical branch pipe. The axes of both pipes lie in a common vertical plane. * An auxiliary view of the branch pipe Instructions: Draw, to scale 1: 1, the following views of the TWO pipes: 2.1. The given top view 2.2 The complete front view, clearly showing the curve of interpenetration 2.3 The development of the cylindrical branch pipe. Make AB the seam. * Planning is essential. * Show ALL hidden detail. * Show ALL construction. 137] 256 Ba 4 | A 30" | y ‘AB IS THE SEAM ASSESSMENT CRITERIA 1 |TOP view 103 2, [FRONT View + CIRCLE 6s DIVISION 2 3, [CURVE OF 9 INTERPENETRATION 4 |DEVELOPMENT 1 PENALTIES (-) TOTAL| 37 EXAMINATION NUMBER EXAMINATION NUMBER [3] Please tu over
Engineering Graphics and Design/P1 Downloaded fram hlayiso.com DBE/2019 PP. QUESTION 3; PERSPECTIVE Given: Three views of a building and the information needed to draw a two-point perspective drawing PP — Picture plane HL - Horizon line GL - Ground line SP - Station point Instructions: Complete the perspective drawing. * Align the drawing sheet with the ground line (GL). * Determine and label the vanishing points. * Show ALL construction. * NO interior detail is required. * NO hidden detail is required. [38] ASSESSMENT CRITERIA CONSTRUCTION 6 1 2 |FLOOR AND WALLS 10 3 |DOOR AND WINDOWS 133 4 |ROOF 384 PENALTIES (-) TOTAL | 38 GL GL sP Copyright reserved EXAMINATION NUMBER: EXAMINATION NUMBER, [4 Please tum over
Engineering Graphics and Design/P1 Downloaded fram hlayiso.com DBE/2019 4550 2970| INCOMPLETE FLOOR PLAN @ ROOF NOTES: 30° ROOF PITCH 414 x 38 mm ROOF TRUSS ON 114 x 38 mm WALL PLATES, 240 mm ROOF OVERHANG TO END OF ROOF TRUSS 30 mm CORRUGATED ROOF SHEETING ON 75 x 50 mm PURLINS @ 1000 mm cle 300 x 75 x 10 mm BARGE BOARD ON GABLE ENDS, 20 mm PAST THE GUTTER 300 x 20 mm FASCIA BOARD WITH 140 x 100 mm GUTTERS ON ALL SIDES 9 mm CEILING BOARD ON 38 x 38 mm BRANDERING STRIPS @ 400 mmclc Ve # ‘SCHEMATIC DIAGRAM OF A ROOF TRUSS FOR ROOF 'A’ SCHEMATIC DIAGRAM OF A ROOF TRUSS FOR ROOF ‘8° x75x —— — = Boek” 10mm BARGE I ——————1 ELECTRICAL DOOR AND WINDOW SCHEDULE | | } SYMBOLS I I Hh Poa us ! peel laa 140x100 mmGUTTERONA | f “ ' — ra 30x20 mm FASCIABOARD = || L__y | ! I I 4 100 mm RWDP- ! ! i Ib A DOOR OPENING rf 3 4 i g 4000 x 300 x 150 mm ' ! |! 3 g Is CONCRETE STEPS, | | A OA Ee = FINISHED FLOOR LEVEL x g GROUND LEVEL c /8 400 «400 x 180 GULLY ROOM DESIGNATIONS k a0W * “x FLOOR FINISHES FEATURES 1 BATHROOM: TILE or DOOR FRAME WINDOW (w1) D Door 2 LIVING ROOM: CARPET AND DOOR (D) wi Tows WINDOWS 3 KITCHEN TILE DOOR NOTE: 75 x 100 mm LINTELS we TOILET ABOVE THE DOORS 4150 WB = WASHBASIN fe (s06 1 sH SHOWER s SINK 004 ELECTRICAL FITTINGS 3 4. ONE-WAY SWITCH - SINGLE-POLE RAIN WATER e 8 S| lle alll c 2. ONE-WAY SWITCH - DOUBLE-POLE ITEMS z| - 3, FLUORESCENT LIGHT 2.x 40 W A 4, CEILING LIGHT 5. SWITCHED SOCKET OUTLET an 90, 6, DISTRIBUTION BOARD EN LAY WINDOW (w2) WINDOW (W3) NoTE: soo WINDOW NOTES: THE ARROW SHOWS THE LIGHT A= Mee CONNECTION TO THE SWITCH. FIXED PANEL © 150 x 20 mm FIBRE CEMENT SILL UNDER ALL WINDOWS Poy, 199 ° @ 100 x sf 4 ROOF COMPONENTS 300 220, | ROOF CAP { = | 114x38 mm WALL PLATE 2 2 8 8 LI | 140 x 100 mm GUTTER FIXTURES. [* mm SCREED | Es x 8 200 GROUND. & |. o| Sk — ro 500 LEVEL = Her 3 XT El as Ey $ Z| \_] i cre . aay 800) 400 ES FLoorLever J INCOMPLETE WALL AND , 3 ap SR . FOUNDATION DETAIL OF AN e 84 z \e) 8 8 | = EXTERNAL AND AN 8 50 ~ a0 a — - . INTERNAL WALL # va # A X coua._| cova) # 900 + SHOWER (SH) SINK (S) WASHBASIN (WB) TOILET (WC) Copyright reserved QUESTION 4: CIVIL DRAWING Given: © The incomplete west elevation of a new house showing the walls, the door and window openings, the roof and notes © The incomplete floor plan showing the walls, positions of the doors, windows, fixtures and the electrical layout * Roof notes and a schematic diagram of roof truss truss 'B’ Room designations and floor finishes © The incomplete wall and foundation detail of an external and an internal wall * A table of electrical symbols * A table of rain water items * A door and window schedule * A table of roof components * A table of fixtures * The incomplete floor plan of the new house, drawn to scale 1: 50 and the incomplete foundation of a detailed section, drawn to scale 1 : 20, on page 6 and roof Instructions: Answer this question on page 6. 4.1 Using the given incomplete floor plan, draw, in first-angle orthographic projection and to scale 1 : 50, the following views of the new house: 4.1.1 THE COMPLETE FLOOR PLAN Add the following features to the drawing: * ALL doors and windows * The fixtures as indicated by the abbreviations * ALL electrical fittings as indicated by the numbers * ALL hatching detail 4.1.2 THE COMPLETE WEST ELEVATION Show the following features on the drawing: * The outside walls, gullies, steps and door detail * The roof detail, including the barge boards, fascia board, gutter and rainwater down-pipes The finished floor level 4.2. Using the incomplete foundation on page 6, draw, to scale 1:20, a DETAILED SECTION on cutting plane A-A of the area in the ellipse shown on the incomplete floor plan Show the following features on the drawing: ¢ The wall and foundation detail of both walls * The door detail © The roof detail, including the fascia board, barge board and gutter * The shower, tollet and the window above the ellipse * ALL hatching detail. ONLY the substructure hatching may be drawn in neat freehand. Label the following: © The west elevation © The room designations and floor finishes © Ground level, finished floor level and damp-proof course (use the correct abbreviations and show it on ALL the relevant views) NOTE: ALL drawings must comply with the guidelines and graphical symbols as contained in the SANS 10143. [95] [5 Please tum over
Downloaded fram hlayiso.com Engineering Graphics and Design/P1 DBE/2019 1, MARK ee FOR OFFICIAL USE ONLY BOORSECTION INCORRECT SCALE(S) A(1) USED: B(1) NON-ALIGNMENT OF C2) VIEWS De) VIEW(S) ROTATED E (2) SECTION VIEWED F(t) INCORRECTLY ._] ] INCORRECT 0) LETTERING Ht) i) TOTAL TOTAL ASSESSMENT CRITERIA FLOOR PLAN POSSIBLE | oBTaNED | SIGN | nooeRaTeD 1 | fomoows 10 2 | eccoriioa 6 3 | roures 8 4 | natcHne 3 J ‘| 5 |usves 3 | t 1 | 1 | SUBTOTAL 30 | | Le WEST ELEVATION A lteawbe fmm | 0 Li \ W I 2 | Waus+rrL ed f / | aan iA 4 3 [ay | 2 Z BIC | , | 7 | 4 | sets 14 7 | | 4 | SUBTOTAL 20 | | < DTT TT DETAILED SECTION | | \ | 1 ] roo vera 15 N | | \ | 9. | FOUNDATION + 1 | | \ | WALL + DOOR 142 | | \. | 3 | wegsnower | 7 | | 4 | HarcHINe 7% eRe | ere) | ‘\- Tina | vases 1 | | cy ele) | | SUBTOTAL 45 | i | RWDP_ __ ee a] TOTAL 95 PENALTIES (-) GRAND TOTAL EXAMINATION NUMBER: DETAILED SECTION A-A FLOOR PLAN SCALE 1 : 20 SCALE 1: 50 EXAMINATION NUMBER [ 6 Copyright reserved