Downloaded from hlayiso.com INSTRUCTIONS AND INFORMATION 1. This question paper consists of FOUR questions. 2. Answer ALL the questions. 3. ALL drawings are in first-angle orthographic projection, unless otherwise stated. 4. ALL drawings must be completed using instruments, unless otherwise stated. 5. ALL answers must be drawn accurately and neatly. 6. ALL the questions must be answered on the QUESTION PAPER as instructed. 7. ALL the pages must be re-stapled in numerical sequence, irrespective of whether the question was attempted. 8. Time management is essential in order to complete all the questions. 9. Print your examination number in the block provided on every page. 10. Any details or dimensions not given must be assumed in good proportion. NATIONAL SENIOR CERTIFICATE FOR OFFICIAL USE ONLY QUESTION MARKS OBTAINED ½ SIGN MODERATED ½ SIGN 1 GRADE 12 2 3 ENGINEERING GRAPHICS AND DESIGN P1 4 TOTAL FEBRUARY/MARCH 2015 2 0 0 2 0 0 MARKS: 100 FINAL CONVERTED MARK CHECKED BY TIME: 3 hours _______ 100 COMPLETE THE FOLLOWING: CENTRE NUMBER This question paper consists of 6 pages. CENTRE NUMBER EXAMINATION NUMBER EXAMINATION NUMBER *BASIC-EDUCATION* Copyright reserved Please turn over
Engineering Graphics and Design/P1 Downloaded from hlayiso.com DBE/Feb.-Mar. 2015 6000 x 850 x 2000 DEEP. SOAK PIT SEPTIC 4 TANK BRICK PAVING | EXISTING ai ‘3 ich POOL BAN 1 REN, easine | a] ( ouTBULDING | )3 + STAND ‘ + RE STAND iS 322°«¢8 | | 31 y Ps ' 5 | | EXISTING BRAAI | 9g iE id H 2a RE a " | RE 5000 BL. _-WIRE FENGE PAVEMENT Ww 6000 MULLER STREET ois A SITE PLAN on) SCALE 1 : 300 PAVEMENT GOTZE STREET 3520 NOTE: Contractors must verify all dimensions and levels on site before commencing work. Architects to be notified immediately of any discrepancies. ARCHITECTS SIGNATURE CLIENT'S SIGNATURE QUESTION 1: ANALYTICAL (CIVIL) Given: The site plan for a proposed new dwelling, a title panel and a table of questions. The drawing has not been prepared to the indicated scale. Instructions: Complete the table below by neatly answering the questions, which refer to the accompanying drawing and title panel [30] ANSWER 20 QUESTIONS ANSWERS In the space provided below, draw, in neat freehand, the front view and top |_1__| Whats the reference code for the drawing? 1 view of the SANS 10143 graphical |~> | What was th d revision? 1 symbol for a DOUBLE SINK. at was the second revision 3. | What scale is indicated for the drawing? 1 4 |How many inspection chambers are there on the sewer line? 1 5 | What finish is used around the pool? 1 6 | What new development is proposed on the site? 1 7 | In what colour would new glass be presented on a drawing? 1 8 | In what colour would new concrete be presented on a drawing? 1 9 | What is the depth of the feature at 17 1 10 | Name the feature at 2. 1 11 | What does the number at 3 indicate? 1 12 | What does the line at 4 indicate? 1 13 | Name the feature at 5. 1 3 14 |Name the feature at 6. 1 15 | Which elevation of the new dwelling faces Gotze Street? 2 2 2014-12-07| Include a soak pit 46 | Whatis the distance from the swimming poo! to the south-western 2 + | 2014-11-09) Change driveway boundary line in metres? 2 Revision| pate. | DESCRIPTION 17 | What is the length of the boundary facing stand 32 in metres? 2 4g | In the space below, determine the perimeter of the new dwelling 3 TONY KROOS & ASSOCIATES in metres. ARCHITECTS In the space below, determine the total building area of stand 31 BAYERN DRIVE 19 |. 3 13-46 MUNICH GARDENS in square metres. NEW GERMANY & PINETOWN In the space provided in the title panel, draw, in neat freehand, tonroontbundoscom 20 | the front view and top view of the SANS 10143 graphical symbol 4 PRINTED BY DATE OF PRINT for a DOUBLE SINK. FUSSBAL PRINTERS 2015-02-12 DRAWING TITLE, TOTAL 30 SITE PLAN e000 ROK ANSWER 18 80 ANSWER 19 Show ALL calculations. 5 Show ALL calculations. PROPOSED DWELLING FOR MR 3 g RIBERY ON STAND 31, CNR 3 NEW DWELLING 8 MULLER STREET AND GOTZE + 4 STREET. 8 PROJECT NUMBER DRAWING NUMBER my CHLW-2013 BM 3113 3109 | 3100, DATE Raum [Ove] SCALE a a 2015-01-28) ARJEN ROB 1:300 EXAMINATION NOMBER: REFERENCE CODE EXAMINATION NUMBER [2 Copyright reserved 1vG2014 | Please tum over
Engineering Graphics and Design/P1 Downloaded from hlayiso.com DBE/Feb.-Mar. 2015 QUESTION 2: TRANSITION PIECE Given: The front view and the top view of a square- to-irregular four-sided transition piece. Instructions: Draw, to scale 1 : 1, the following views of the transition piece: 2.1. The given top view 2.2. The given front view 2.3. The development of the transition piece NOTE ABis the seam. [36] if — i 27 » Fl A BLA 3 & ASSESSMENT CRITERIA 1 |FRONTAND TOP view | 14 2 | TLCONSTRUCTION 8 3 | DEVELOPMENT 17 PENALTIES (-) TOTAL 36 EXAMINATION NUMBER EXAMINATION NUMBER [3 Copyright reserved Please tum over
Engineering Graphics and Design/P1 Downloaded from hlayiso.com DBE/Feb.-Mar. 2015 QUESTION 3: PERSPECTIVE Giver Two views of an entrance with a control point and the information needed to draw a two-point perspective drawing PP - Picture plane HL - Horizon line GL - Ground line SP - Station point Instructions: Complete the perspective drawing * Align the drawing sheet with the ground line (GL). * Determine and label the vanishing points. * Show ALL necessary construction. * Show the wall thickness at the window and door. * NO internal or hidden detail is required. [40] ‘S ASSESSMENT CRITERIA 1. |CONSTRUCTION+ VPs | 7 PP 2 | ROOF 4 3 | WALLS 17 4 | QUARTER-CIRCLE 6 5 | WINDOW + DOOR 6 PENALTIES (-) TOTAL 40 HL T i i i i i i i i i i i i I I i i i i i i I I i i i i i i i i i i i i i i GL H H Copyright reserved EXAMINATION NUMBER EXAMINATION NUMBER [4 Please tum over
sou uu Downloaded from hlayiso.com DBE/Feb.-Mar. 2015 DOOR AND WINDOW SCHEDULE QUESTION 4: CIVIL DRAWING FLOOR FINISHES. yp TOFIT y --TOFIT 14,50 Given: 20" J eavnoca oAreT 1 ry 5 * The incomplete south-west elevation of a new cottage, 1 100x180 GUTTER 3 KITCHEN TILE showing tho wals, the verandah pillars, the sliding door L. L_—— 200 x20 FASCIA BOARD 4 LOUNGE: TILE opening, the roof and notes e P| SLIDING DOOR OPENING 5 VERANDAH: GRANO oS ONL * The incomplete floor plan showing the walls, position of the Fe} > a ee RS ol ol verandah pillars, doors, windows, fixtures and electrical layout | VERANDAH LEVEL a s 3 # Roof notes with a schematic diagram of a roof truss - - L GROUND LEVEL H * Room designations and floor finish [ \ * Verandah pillar and beam detail r I © The incomplete foundation ‘A’ and verandah detail INCOMPLETE SOUTH-WEST ELEVATION Dt SLIDING DOOR | * The incomplete foundation and external wall detail D2 INTERNAL DOOR Hl « A door and window schedule Wi WINDOW ' se SLIDING DOOR INTERNAL DOOR | « A table of rainwater items we WINDOW t WITH FRAME (01) FRAME AND DOOR | ¢ A table of roof components FIXTURES MI (02) © A table of electrical symbols we TOILET ROOM DESIGNATIONS 1550 600 © A table of fixtures WB WASH BASIN eo EE now NOTE: The incomplete foundation ‘A’ and floor plan of the new st SER ls] A=OPENINGSive | cottage, drawn to scale 1 : 50, on page 6 ai) ale Ia ||) 8= Fixe PaNeL ELECTRICAL FITTINGS =| Instructions: 4. LIGHT SWITCH - SINGLE-POLE WINDOW (W2) es mm FIBRE ‘Answer this question on page 6. F FLUORESCENT LIGHTS nao mo mo CEMENT SILLUNDER| 4,1 Using the given incomplete floor plan, draw, in first-angle 4, CEILING LIGHT ALL WINDOWS orthographic projection and to scale 1 : 50, the following 5. WALL MOUNTED LIGHT winDow (wt) views of the new cottage: 8. SWITCHED SOCKET OUTLET 4.1.1 THE COMPLETE FLOOR PLAN 7, DISTRIBUTION BOARD Add the following features to the drawing: NoTE: RAINWATER ROOF COMPONENTS ® ALL doors and windows THE ARROW SHOWS THE LIGHT ITEMS 200 x.20 mm FASCIA BOARD| * ALL fixtures as indicated by abbreviations < CONNECTION TO THE SWITCH. ra * ALL electrical fittings as indicated by numbers |p | 12050 x 7250.mn INCOMPLETE FLOORPLAN ®& g 50 ey 0 Frivoer Bea Ao THE SOUTHWEST ELEVATION S Sa (20 75 x 50 mm PURLINS Show the following features on the drawing: f T ian * The outside walls, verandah and sliding door detail \ * The roof detail, including the fascia board, gutter, rain- | 420 x50 x 7250 mm 18 ELECTRICAL SYMBOLS . water down pipe and guly TIMBER BEAM ors ~ eld ocd mH 4.2 Using the given incomplete foundation ‘A’, draw, to scale ROOF NOTE! 3 1: 20, a DETAILED SECTION on cutting plane A-A of Roo prc 20° WITH 200 x 20 mm FACIA & RwDP co is} fe) the area in the ellipse shown on the incomplete floor plan. BOARD ON ALL SIDES ee ONING Py SJ * Show the following features on the drawing: ROOF COVER 15 mm FIBRE CEMENT SHEET og xX awl * The complete foundation ‘A’ and verandah detail ON 75 x 50 mm PURLINS @ 900 mm cle a = K . The complete foundation, external wall and sliding door A < i 189 x 38 mm ROOF TRUSS ON 115 x 38 mm L| g GULLY (6) = ¢ The roof detail, including the fascia board and gutter 8 * ALL features of the verandah to the left of cutting plane 9 mm CEILING BOARD ON 38 x 38 mm 200 x 200 mm VERANDAH FIXTURES A-A, including the rainwater down pipe and gully BRANDERING STRIPS @ 600 mm cle PILLAR AND BEAM DETAIL 500 * ALL hatching detail. ONLY the substructure hatching ee = may be drawn in neat freehand 4100 x 150 mm GUTTER ON ALL SIDES 25mm SCREED > iy [ 3 1000 /T~ be. |e Ts a 8 Label the following: 5 8 S 8 2] =| * The south-west elevation gs g|GROUND LeveL — soon LEVEL {8 8] | » The room designations and floor finishes - a Ls 2/8 < LE") + Using the correct abbreviations, label the following features in EQUAL | EQUAL | EQUAL | EQUAL A = lle Z =i / is vO} the correct view: ground level and finished floor level. ‘OF 3 /8] SINK (S) ‘SCHEMATIC DIAGRAM OF A ROOF TRUSS 600 600. ° 200) NOTE: . ALL drawings must comply with the guidelines and graphical INCOMPLETE FOUNDATION ‘A° INCOMPLETE FOUNDATION WASH BASIN TOILET = SHOWER symbols contained in the SANS 10143. [94] “AND VERANDAH DETAIL AND EXTERNAL WALL DETAIL (WB) (we) (Ss) LAA I Copyright reserved aN Please tum over
Engineering Graphics and Design/P1 Downloaded from hlayiso.com DBE/Feb.-Mar. 2015 a4 DETAILED SECTION SCALE 1 : 20 PENALTIES INCORRECT OVERALL SCALE INCORRECT POSITIONING OF VIEWS. NON-ALIGNMENT OF VIEWS TOTAL PENALTIES (-) RWDP FLOOR PLAN Copyright reserved ASSESSMENT CRITERIA FLOOR PLAN posse | ostaneo | sian | mooerare ee = |! WINDOWS 12 RWDP | [2 [etcermca 10 | [3 | rocrures 4 \ | 7 4 \ BIC | \ | | 5 [eases 5 \ \ | SUBTOTAL 35 | SOUTH-WEST ELEVATION LN | 1 | ROOF 6% | | [2 peresecty | 9 | 3 | poor 3 | [4 [wees 1% | SUBTOTAL 20 | DETAILED SECTION | [a | RooF beraL 12 | [a [roumoarons* ayy, WALLS + S.AB | DOOR + GULLY | Ja |Rwor+ 9 | GurTER | [4 |ratoHns 6% | SUBTOTAL 39 | TOTAL 94 | TOTAL PENALTIES (-) FINAL TOTAL EXAMINATION NUMBER EXAMINATION NUMBER [6 SCALE 1:50 OMA