Skip to content

Engineering Graphics and Design Grade 12 P1 2018 QP (Eng)

Question paperEngineering Graphics and DesignGrade 1220186 pages

Grade 12 Engineering Graphics and Design Paper 1 question paper from the NSC November Exam 2018 (English), 6 pages. Read online or download the free PDF.

Free to read online, no sign-up needed

Answer online

Loading document…

Loading document…

Questions in this paper

Document textSearch extracted text and jump to a page.
basic education Department « y) Basic Education "4 REPUBLIC OF SOUTH AFRICA NATIONAL SENIOR CERTIFICATE i ENGINEERING GRAPHICS AND DESIGN P1 i] i NOVEMBER 2018 MARKS: 100 TIME: 3 hours Copyright reserved This question paper consists of 6 pages. FOR OFFICIAL USE ONLY QUESTION ]] MARKS OBTAINED | 3 | SIGN MODERATED |} siGN RE-MARKING | 3] SIGN 1 2 3 . 1 4 1 i TOTAL | ) 2])0/0 2/0/0 2])0/0 FINAL CONVERTED MARK CHECKED BY 100 oe _ INSTRUCTIONS AND INFORMATION This question paper consists of FOUR questions. Answer ALL the questions. ALL drawings are in first-angle orthographic projection, unless otherwise stated. ALL drawings must be prepared using pencil and instruments, unless otherwise stated. ALL answers must be drawn accurately and neatly. ALL the questions must be answered on the QUESTION PAPER, as instructed. ALL the pages, irrespective of whether the question was attempted or not, must be re-stapled in numerical sequence in the TOP LEFT-HAND CORNER ONLY. 8. Time management is essential in order to complete all the questions. 9. Print your examination number in the block provided on every page. 10. Any details or dimensions not given must be assumed in good proportion. BOND Non COMPLETE THE FOLLOWING: CENTRE NUMBER CENTRE NUMBER EXAMINATION NUMBER | | | Barcode label | | | | EXAMINATION NUMBER Please tum over
Engineering Graphics and Design/P1 DBE/November 2018 LAND SURVEYOR'S CERTIFICATE OF THE BOUNDARY LENGTHS AND CORNER HEIGHTS OF STAND 3289, SURVEYED ON 2017-08-31 BOUNDARY LENGTHS IN | CORNER HEIGHTS IN MILLIMETRES METRES ‘AB = 22500 A= 1259 BC = 9850 B= 1259 CD = 26690 c= 1259 DE = 65050 D=1259 EF = 49190 E= 1260 FA = 74900 F = 1260 Ey EXISTING | ge | ABEUTION 3 ' beacuity NIE 2 _ i « L 2 ' Ra EXISTING | 12m STORE VEHICLE H ENTRANCE | | EXISTING AUTO WORKSHOP | | ‘ ol 2 | E al STAND 3289 SLIDING j| be @) 2 ec cate! 1 S | 24 EXISTING med 2 Gi : = PARKING 4) |& | 2 rf asi a| e| | ET; 3 ahi? i i A] a™ Fa g le | ' Es zg ie ' { = |e | a i qy ik a i | z |& ! a . & IE b IEE - | @ = |n MH MH a 2 g oN rt 3 ON SLIDING 5 \Sys GATE \i CONN new | VPs PARKING | 10m VEHICLE a [propose NEw | ENTRANCE AUTO PARTS DEALERSHIP H 41000 BL I | id © — ae / ‘STAND 3290 18m PALISADE _/ FENCING SITE PLAN SCALE 1: 500 & NOTE: Contractors must verify all dimensions and levels on site before commencing work Architects to be notified immediately of any discrepancies. ARCHITECT'S SIGNATURE: .. CLIENT'S SIGNATURE: wasesstistnnessnnarnei Downloaded from hlayiso.com QUESTION 1: ANALYTICAL (CIVIL) Given: The site plan of an existing auto dealership and workshop with a proposed new auto parts dealership, a title panel and a table of questions. The drawing has not been prepared to the indicated scale. Instructions: Complete the table below by neatly answering the questions, which refer to the accompanying drawing, title panel and civil content. [30] ANSWER 19 QUESTIONS ANSWERS In the space below, draw, in neat freehand and according to the 1 | What is the title of the drawing? 1 SANS 10143 > 3) FACE BRICK hatching 2. | On what date was the drawing prepared 1 b) The graphical symbol fora GULLY | 3 | What scale is indicated for the drawing? 1 3 # 4 | What is the name of the proposed new street? 1 5 | How many existing buildings are there on STAND 3289? 1 6 | How many parking bays are shown? 1 7 | What does the abbreviation RE stand for? 1 8 | How wide are the pavements in millimetres? 1 9 | What do the two arcs at 1 indicate? 1 >) 10 | Name the feature at 2. 1 41 | How many manholes are shown? 1 12 | What type of fencing surrounds STAND 3289? 1 13 | What feature is shown on STAND 3288? 1 14 What is the number of the STAND south west of 2 STAND 3289? 15 | Why is the existing ramp shown with broken lines? 1 16 | What does the arrow on the line at 3 indicate? 41 17 | What is the fall of the sewer line? 1 In what colour could new concrete be indicated on a layout 18 | drawing? i REVISION | DATE DESCRIPTION 4g | inthe space in the tite panel (ANSWER 19), draw, in neat freehand and according to the A ERESH DESIGNS SANS 10143 a) FACE BRICK hatching, and b) the graphical symbol for a GULLY. 51 Munnik Street Bray 20 | In the space below (ANSWER 20), determine the total length of the fence in metres. 4 010 810 4921 fd.architects@gmail.com 1 In the space below (ANSWER 21), determine the total area of the proposed new auto parts 3 building in square metres. Round off the answer to THREE decimal places. PRINTED BY. DATE OF PRINT LPRINT 2018-05-21 TOTAL | 30 DRAWING TILE ANSWER 20 7200 ANSWER 21 SITE PLAN Show ALL calculations. —— Show ALL calculations. PROVECT PROPOSED NEW AUTO PARTS DEALERSHIP FOR REGROW HOLDINGS ON STAND 3289, MAIN ROAD, PORT ELIZABETH. 2 PROJECT NUMBER DRAWING NUMBER 5 FDBS-2018 10F7 s [as DATE Raw CHECKED, SOALE PROPOSEDNEW | | 2018-04-05] | MP cic | 1:500 Autoparts || REFERENGE CODE DEACERSHIE, EXAMINATION NUMBER a1Pt-2018 18300, EXAMINATION NUMBER [2 Copyright reserved Please tum over
Engineering Graphics and Design/P1 DBE/November 2018 Downloaded from hlayiso.com Copyright reserved QUESTION 2: SOLID GEOMETRY Given: © The front view of a right equilateral triangular pyramid and a right regular hexagonal prism « The top view of the pyramid and the axis of the prism © An auxilliary view of the prism © Cutting plane A-A Specifications: © The prism leans against the pyramid. * Both solids are cut by cutting plane A-A. Instructions: Draw, to scale 1 : 1, the following views of the TWO solids: 2.1 The given front view 2.2 A sectional top view 2.3 A sectional left view 2.4 The true shape of the cut surfaces Planning is essential Show ALL construction Show ALL hidden detail [40] ASSESSMENT CRITERIA 1 | CONSTRUCTION 1 2 | FRONT view 53 3. | SECTIONAL TOP VIEW 143 4 | SECTIONALLEFT VIEW | 124 5 | TRUE SHAPE 63 PENALTIES () TOTAL | 40 EXAMINATION NUMBER EXAMINATION NUMBER 3 Please tum over
Engineering Graphics and Design/P1 Downloaded from hlayiso.com DBE/November 2018 QUESTION 3: PERSPECTIVE Given: Two complete views and a partial view of a function hall and the information needed to draw a two-point perspective drawing PP - Picture plane HL - Horizon line GL - Ground line SP - Station point Instructions: Complete the perspective drawing. * Align the drawing sheet with the ground line (GL). « Determine and label the vanishing points « Show internal lines seen through the doorway. * Show ALL construction. * NO hidden detail is required. [37] ASSESSMENT CRITERIA 1 |CONSTRUCTION 6 2.) ouTER STRUCTURE 93 3] INNER STRUCTURE 8 4 | SIDE STRUCTURE Copyright reserved 5 | ARCS 64 PENALTIES () PP TOTAL | 37 HL HL GL - GL EXAMINATION NUMBER EXAMINATION NUMBER [4 Please tum over
Engineering Graphics and Design/P1 Downloaded frem hlayiso.com FOUNDATIONS AND WALLS FOR THE VERANDA DBE/November 2018 ye H H DOOR AND WINDOW SCHEDULE. g i ' = : . 300x75x10mmBARGEBOARD | ! % i i TO FIT = a ! | Va x 2 200 x 20 mm FASCIA BOARD i i 3 WINDOW OPENING t H F{— SLIDING DOOR OPENING FINISHED FLOOR LEVEL GROUNDLEVEL e a ROOM DESIGNATIONS FEATURES FLOOR FINISHES yy D1 DOOR 1.BEDROOM: CARPET — b2 SLIDING DOOR 2.VERANDA: — GRANO DOOR (01) W1 TO W3 WINDOWS 3. LIVING AREA: WOOD o Tort 4, KITCHEN TILE g c |iA 3 x H FIXTURES 5.BATHROOM: TILE x wc TOILET WB WASHBASIN 4 SH SHOWER WINDOW (w1) s SINK pb ELECTRICAL FITTINGS s 2 —- 1, ONE-WAY SWITCH - SINGLE-POLE ol S 2, ONE-WAY SWITCH - DOUBLE-POLE | 3. FLUORESCENT LIGHT 2 x 40 W A 4, WALL-MOUNTED LIGHT 5. CEILING LIGHT WINDOW (wa) 6. SWITCHED SOCKET OUTLET 1700 Re 7. DISTRIBUTION BOARD 565 SLIDING DOOR (02) ELECTRICAL t H NOTE: x : THE ARROW SHOWS THE LIGHT SYMBOES ee ANE SIDE CONNECTION TO THE SWITCH. — Ss + B= HINGED SIDE 8 + C= FIXED PANEL s c ip Al S #150 x 20 mm FIBRE fo) CEMENT SILL UNDER Jo, ALL WINDOWS 060.4 fo} x * ALL FRAMES 50 mm To THICK Ps 20060 mm LNTELS ABOVE A ENDOW (9) ~ ~ ALL DOORS, WINDOWS oe fe) lacuna —- ~ AND OPENINGS, ALL AT THE ) EQUAL | EQUAL | EQUAL | EQUAL |, SAME HEIGHT x ROOF COMPONENTS SCHEMATIC DIAGRAM OF A S o 114 x 38 mm ] 300 x 75 x 10 mm FIBRE ROOF TRUSS \ a WALL PLATE CEMENT BARGE BOARD 200 x 20 mm FASCIA | 300 ROOF NOTES: a \ PY nxaow I BOARD oom ROOF CAP 20° ROOF PITCH / in 114 x 38 mm ROOF TRUSSES ON 114x 38 r/ | x38 mm x38.mm WALL PLATES SLIDING PATIO FIXTURES PENN Hy 4 ‘OPENING 240 mm ROOF OVERHANG TO END OF ROOF OPENING @ TRUSSES 3 . - 1200 | s xr uf 5 x 30 mm CORRUGATED ROOF SHEETING ON ge I [al 8 i 75 x 50 mm PURLINS @ 1060 mm cic al& 450 |, 5 850 300 x 75 x 10 mm BARGE BOARD ON GABLE x ENDS, 20 mm PAST THE GUTTER g si FLOOR LEVEL Bs T x 200 x 20 mm FASCIA BOARD ON BOTH SIDES glad ye NGL 0, 5 318 gy | 150 x 100 mm GUTTER ON BOTH SIDES WITH = oy SN 100 RAINWATER DOWN-PIPES LC igt DC L 600 10 mm CEILING BOARD ON 38 x 38 mm # 7 BRANDERING STRIPS @ 460 mm cic INCOMPLETE DETAIL OF TOILET WASHBASIN SHOWER SINK (WC) (we) (SH) (s) Copyright reserved ( QUESTION 4: CIVIL DRAWING Given: * The incomplete west elevation of a new house showing the walls, the sliding door and window openings, the roof and notes © The incomplete floor plan showing the walls, positions of the doors, windows, fixtures and the electrical layout * A schematic diagram of a roof truss and roof notes * The incomplete detail of the foundations and walls for the veranda * Room designations and floor finishes * A table of electrical symbols * A door and window schedule * A table of roof components * A table of fixtures * The incomplete floor plan of the new house, drawn to scale 1: 50, and the incomplete foundation and break line of the detailed section, drawn to scale 1 : 20, on page 6 Instructions: Answer this question on page 6 4.1. Using the given incomplete floor plan, draw, in first-angle orthographic projection and to scale 1 : 50, the following views of the new house: 4.1.1 THE COMPLETE FLOOR PLAN Add the following features to the drawing: * ALL doors and windows * The fixtures as indicated by the abbreviations * ALL electrical fittings as indicated by the numbers * ALL hatching detail 4.1.2 THE COMPLETE WEST ELEVATION Show the following features on the drawing: © The outside walls, sliding door and window detail * The veranda detail © The roof detail, including the roof cap, barge boards, fascia board, gutter and rainwater down-pipe © The finished floor level 4.2 Using the incomplete foundation and break line on page 6, draw, to scale 1 : 20, a DETAILED SECTION on cutting plane C-C of the area in the ellipse shown on the incomplete floor plan Show the following features on the drawing: *The complete detail of the foundations and walls for the veranda * The door detail © The roof detail, including the fascia board, gutter and barge board * ALL hatching detail. ONLY the substructure hatching may be drawn in neat freehand. Label the following: © The west elevation © The room designations and floor finishes * Ground level, finished floor level and damp-proof course (use the correct abbreviations and show them on ALL the relevant views) NOTE: ALL drawings must comply with the guidelines and graphical symbols as contained in the SANS 10149. [93] 5] Please tum over
cums Downloaded frem hlayiso.com — - MARK ALLOCATION FOR OFFICIAL USE ONLY La % FOR ROOF Oe SECTION (4.2) ¢ INCORRECT SCALE A(1) NON-ALIGNMENT OF B(1) VIEWS ce VIEW(S) ROTATED D(3) SECTION VIEWED E (2) INCORRECTLY F(t) INCORRECT G(1) LETTERING H (2) 1) Tc TOTAL TOTAL ASSESSMENT CRITERIA FLOOR PLAN 1 | bo0Rs + winoows 133 2 | Foctures 7 oo 3 | etecTRca, 93 RWODP © oT | 4 ern 4 | narcrns 4 | | 5 | vssets 5 | | | | SUBTOTAL 39 | | WEST ELEVATION | | 4 | 1 | RooF + RwoP 5} | | 2| waus+Feu+ster 4 | | | 3 | 0008 + winoow 74 yl | < 4 | uses 14 Bb pj fe 4 s SUBTOTAL | 184 8 =| | DETAILED SECTION | | 4 | Roor 12 | | | c | 2| Stas ooorsinrer | 132 | ao] I 3 | HaTcHIna 9 | | 4 | vaseis 4 | | SUBTOTAL 353 | | TOTAL| 93 io | TOTAL PENALTIES (-) ORWDP ea Oy — GRAND TOTAL FLOOR PLAN EXAMINATION NUMBER: C SCALE 1:50 DETAILED SECTIONC-C PP UNA —- pamenonniees [8 Copyright reserved La

Study this subject

More from Grade 12 Engineering Graphics and Design

View all