Skip to content

Civil Technology Grade 12 NSC November 2025 Memo (English)

MemorandumCivil TechnologyGrade 12202519 pages

Grade 12 Civil Technology memorandum from the NSC November Exam 2025 (English), 19 pages. Read online or download the free PDF.

Free to read online, no sign-up needed

Loading document…

Loading document…

Document textSearch extracted text and jump to a page.
NATIONAL SENIOR CERTIFICATE GRADE 12 CIVIL TECHNOLOGY: WOODWORKING NOVEMBER 2025 MARKING GUIDELINES MARKS: 200 These marking guidelines consist of 19 pages. Copyright reserved Please turn over
Civil Technology: Woodworking 2 DBE/November 2025 NSC – Marking Guidelines INSTRUCTIONS FOR MARKERS 1. Markers should: • Familiarise themselves with the question and answer before evaluating the responses of candidates. • Always interpret the responses of the candidates within the context of the question. • Consider any relevant and acceptable answer during pre-marking but should strictly adhere to the answers after finalisation of the marking guideline. • There are TWO approaches to answering describe and explain type of questions. 1. If a candidate is required to explain e.g., a process in a prescribed number of steps (e.g. 3 steps), only the first required number of responses should be considered. 2. However, if for example candidate is required to explain or describe a process, we need to consider that candidates may write a long description, not necessarily well organised. In this case the marker needs to evaluate the complete statement to judge if the candidate explained the required outcome satisfactorily and allocate marks on merit. • Answering short questions. 1. Bullet Form Answers: When a candidate provides their answers in bulleted points, each bullet should be treated as a single answer. Award 1 mark for each complete bulleted response. 2. Paragraph Form Answers: When a candidate provides answers in paragraph form, the response should be evaluated based on the accuracy and completeness of each fact presented. Award marks for each distinct fact or point made, ensuring that each fact is correctly articulated. • Mark what the candidate wrote and do not interpret or predict responses. • Indicate the tick or cross right at the position where the mark needs to be awarded or where the candidate made the error. • Accept the letter corresponding with the correct answer as well as the answer written in full in multiple-choice questions or similar questions. • Accept incorrect spelling in answers unless the spelling changes the meaning of the answer. • If a learner writes two or more answers separated by a slash (/) mark only the first response, unless the additional answer/s are different names for the same item, e.g. Yale lock/Night latch. In this case, the answer for the response should be awarded and the slash (/) should NOT be considered as an additional answer. 2. For calculations: • A mark is only awarded if the correct unit is written next to the answer. If the question states that the answer must be in a specific unit, a mark will be awarded if the answer is indicated without the unit. • Marks will only be allocated for the correct values if the candidates add instead of multiply. NO marks will be awarded for the calculations and the answer. Copyright reserved Please turn over
Civil Technology: Woodworking 3 DBE/November 2025 NSC – Marking guidelines • Where an incorrect answer is correctly carried over, the marker must recalculate the values, using the incorrect answer from the first calculation. If correctly used, the candidate should receive the full marks for subsequent calculations. • Alternative methods of calculations must be considered, provided that the correct answer is obtained. • For the calculation of quantities marks will be awarded for the correct use of the dimension paper. 3. When marking drawings: • The member for which the mark should be awarded should be drawn correctly in the correct position to receive a mark. • A member incorrectly drawn but wrongfully repeated in another position will be awarded the mark for the repeated incorrect member provided that the marking guideline provides for TWO or more marks for that member (positive marking). • Marks can only be awarded for a label if the label is correctly indicating the correct member. Do not consider labels for members of which the labels were provided on the answer sheet. • Scale drawings should always be marked using an appropriate mask. • If the incorrect/wrong drawing was drawn, the candidate can be awarded for only what was provided for on the marking guideline. • If a line diagram or an orthographic view instead of a pictorial drawing (isometric/oblique/perspective) is drawn, the first assessment criteria for each member will be marked wrong, but marks will be awarded for the subsequent members if TWO or more marks are awarded for the same member. • If candidates draw/give more information than what is required, mark strictly according to the assessment criteria. However, if the additional information alters or contradicts the correct response, the answer should be marked incorrect. 4. Incorrect numbering of questions: • If a candidate numbered incorrectly, but the answer is in the correct position according to the sequence of the questions in the question paper, circle the incorrect numbering and mark the response. • If questions were answered randomly not following the same sequence as in the question paper and the learner numbered incorrectly, the response should NOT be marked. 5. Duplication of responses and questions answered in the correct place: • If a question is answered twice, mark the first response. • If a question should be answered on an answer sheet and the candidate answered it on both the answer sheet and in the answer book, mark the response on the answer sheet and cancel the response in the answer book. • If the question was answered in the answer book instead of on the answer sheet, mark the response in the answer book according to the assessment criteria on the marking guideline. Copyright reserved Please turn over
Civil Technology: Woodworking 4 DBE/November 2025 NSC – Marking guidelines QUESTION 1: OHSA, MATERIALS, TOOLS, EQUIPMENT AND JOINING (GENERIC) 1.1 1.1.1 38 mm ✓ (1) 1.1.2 150 mm ✓ (1) 1.1.3 320 kg per m² ✓ (1) 1.1.4 two ✓ (1) 1.1.5 two ✓ (1) 1.1.6 overhead ✓ (1) 1.1.7 two thirds ✓ (1) 1.1.8 unauthorised persons ✓ (1) 1.1.9 760 x 560 mm ✓ (1) 1.1.10 health and safety ✓ (1) 1.2 C✓ (1) 1.3 Bolts are purchased according to: • Length of the shank ✓ • Diameter ✓ • Type of thread • Head size • Type of head • Strength • Material ANY TWO OF THE ABOVE (2) 1.4 1.4.1 Process of powder coating: Applying a plastic finish/coating in powder form, ✓ by using a spray gun. ✓ (2) Copyright reserved Please turn over
Civil Technology: Woodworking 5 DBE/November 2025 NSC – Marking guidelines 1.4.2 Advantages of applying powder coating to a metal: • Strengthen the metal ✓ • Provides stability • Environmentally friendly • Thicker coat can be applied • More durable • Available in a variety of colours, textures and gloss levels • Withstand higher levels of heat • Thermoset powder coatings have a beautiful appearance • It is cheaper than other methods • Resists corrosion ANY ONE OF THE ABOVE (1) 1.5 Do not use the following to clean a multi detector: • Cleaning agents ✓ • Solvents/Chemicals • Moist cloth ANY ONE OF THE ABOVE (1) 1.6 Two materials that can be detected: • Steel ✓ • Copper ✓ • Brass • Wiring/AC ANY TWO OF THE ABOVE (2) 1.7 Plumb bob ✓ (1) [20] Copyright reserved Please turn over
Civil Technology: Woodworking 6 DBE/November 2025 NSC – Marking guidelines QUESTION 2: GRAPHICS AS MEANS OF COMMUNICATION (GENERIC) NO. QUESTIONS ANSWERS MARKS What elevation is indicated by 1. West elevation/West/W ✓ 1 FIGURE A? Deduce, from the notes column, what 2. Hipped roof ✓ 1 type of roof is indicated by number 1. What energy-generating components 3. are installed on the roof, as indicated Solar Panels ✓ 1 by number 2? 4. Identify number 3. Fascia board ✓ 1 5. Identify number 4. Window sill/Sill ✓ 1 What material is recommended to be 6. Stainless steel ✓ 1 used to manufacture number 5? 7. Identify number 6. NGL/Natural ground level ✓ 1 Write down the abbreviation for 8. FFL ✓ 1 number 7. Identify the end shape used to 9. Round/Square/Rectangular ✓ 1 manufacture number 8. How many built-in cupboards are 10. One/1 ✓ 1 there in the building? Socket outlet/Switch socket What electrical installation has been outlet/Lights/Electrical wiring/ 11. 1 omitted in the building? Switch/Distribution board/ Inverter ✓ What type of material can be used to Timber/Fibre cement/ 12. manufacture the fascia board in uPVC/Aluminium/Stainless 1 FIGURE A? steel/Galvanised sheets ✓ How should the opening direction of 13. the sliding door be indicated on the By means of an arrow ✓ 1 floor plan? Ceramic/PVC/Timber/Steel/ Stainless steel/Porcelain/Clay/ Name ONE material that can be used 14. Plastic/Fibre glass/Glass/Concrete/ 1 to manufacture number 9. Stone/Marble/Terrazzo/ Cast iron/Pressed steel/Brass ✓ Copyright reserved Please turn over
Civil Technology: Woodworking 7 DBE/November 2025 NSC – Marking guidelines Deduce, from the notes column, what 15. Lintels ✓ 1 must be installed above every window. How many external doors are visible 16. Two/2 ✓ 1 on the southern side of the building? How many water closets are installed 17. Four/4 ✓ 1 in the building? 18. Identify number 10. One-way switch double pole ✓ 1 Deduce the thickness of the internal 19. 110 mm/110 ✓ 1 walls from FIGURE B. State the reference code of the 20. QP 5 - 2025 ✓ 1 proposed building. How many 1 200 x 600 mm windows 21. Five/5 ✓ 1 are there in the building? Deduce, from the notes column, the 22. dimensions of the aluminium side 600 ✓ x 2 000 mm ✓ 2 panel with windows. ✓ 23. Draw the symbol for a grease trap. ✓ 3 ✓✓ ✓ Draw the symbol for undisturbed ✓ 24. earth. 3 ✓ ✓ What sanitary fitting is installed in the 25. Sink unit – double/Double sink ✓ 1 scullery? 5✓x4✓ Calculate the area of the scullery to be = 20 ✓ m² covered with floor tiles. 26. The sink unit must be installed on top OR 3 of the tiles. Give your answer in m². = 5 000 mm x 4 000 mm = 20 m² 220 ✓ + 5 000 ✓ + 110 ✓ + 5 000 ✓ + 220 ✓ Calculate the total length of the wall = 10 550 ✓ mm on the northern side of the building. = 10,55 ✓m 27. 7 Show ALL calculations. The length must be indicated in metres. OR 0,22 + 5 + 0,11 + 5 + 0,22= 10,55 m TOTAL: 40 Copyright reserved Please turn over
Civil Technology: Woodworking 8 DBE/November 2025 NSC – Marking guidelines QUESTION 3: CUPBOARDS, CASEMENTS, WALL-PANELLING AND QUANTITIES (SPECIFIC) 3.1 A - Mullion ✓ B - Putty/Glazing beads ✓ C - Window pane/Pane/Glass ✓ D - Transom ✓ (4) 3.2 3.2.1 Three errors on wall-panelling installation: • The cornice is installed incorrectly. ✓ • The tongue-and-groove board should not be placed against the wall/installed incorrectly. ✓ • The rough ground is installed in the wrong place/installed incorrectly. ✓ (3) 3.2.2 1 SKIRTING 2 QUADRANT MOULD NO. ASSESSMENT CRITERIA MARK 1 Skirting (ANY TYPE) 1 2 Quadrant mould 1 TOTAL: 2 (2) 3.3 3.3.1 MEMBER QUANTITY UNIT LENGTH WIDTH THICKNESS Front rail 1 mm 1 200 ✓ 90 ✓ 16 Shelving 3✓ mm 580 576 ✓ 16 Shelf of top unit 1 mm 1 168 580 16 Intermediate 1 mm 1 950 580 ✓ 16 side Sides 2 mm 2 400 ✓ 580 16 Kick plate 1 mm 1 168 80 ✓ 16 (7) Copyright reserved Please turn over
Civil Technology: Woodworking 9 DBE/November 2025 NSC – Marking guidelines 3.3.2 A 3 7 1 5 6 6 2 8 6 6 4 9 9 HATCHING 10 A NO. ASSESSMENT CRITERIA MARK 1 Projection lines (ANY ONE) 1 2 Side 1 3 Side rail 1 4 Bottom of unit 1 5 Top of unit 1 6 Shelving 4 7 Front rail 1 8 Back 1 9 Base (Front and back) 2 10 Hatching (Correct parts) 1 TOTAL: 14 (14) [30] Copyright reserved Please turn over
Civil Technology: Woodworking 10 DBE/November 2025 NSC – Marking guidelines QUESTION 4: ROOFS, CEILINGS, TOOLS, EQUIPMENT AND MATERIALS (SPECIFIC) 4.1 4.1.1 D✓ (1) 4.1.2 A✓ (1) 4.1.3 C✓ (1) 4.1.4 A✓ (1) 4.1.5 D✓ (1) 4.2 4.2.1 A - Bandsaw ✓ B - Spindle moulder ✓ (2) 4.2.2 If the tension of the band saw’s blade is too loose while making cuts: • The accuracy of the cuts will be jeopardized ✓ • The blade will fall off/break/stop moving ✓ • The operator might get injured • The blade could damage the work piece/machine ANY TWO OF THE ABOVE (2) 4.2.3 Equipment used to remove waste material while operating a band saw: • Push stick ✓ • Brush ANY ONE OF THE ABOVE (1) 4.2.4 Clean the machine after use ✓ and apply a thin layer of oil to the surface. ✓ (2) 4.3 4.3.1 Storm clips ✓ (1) 4.3.2 Special aluminium foil ✓ (1) 4.3.3 Hipped roofs ✓ (1) 4.3.4 Closed eaves/Beam filling/Ridge plate/Ridge capping ✓ (1) 4.3.5 Valley ✓ (1) 4.4 4.4.1 A – Truss hanger ✓ (1) 4.4.2 Nailing/Screwing/Bolt and nut ✓ (1) Copyright reserved Please turn over
Civil Technology: Woodworking 11 DBE/November 2025 NSC – Marking guidelines 4.5 Uses of hurricane clips: • To fix purlins to roof trusses ✓ • To fix trusses to wall plates ✓ • Ideally used at eave overhangs • Where members of trusses meet at 90⁰ angles • To fix opposite faces of truss members ANY TWO OF THE ABOVE (2) 4.6 4.6.1 A – Cover strip/Frame ✓ B – Hinged trapdoor/Door ✓ (2) 4.6.2 Hinged trapdoor ✓ (1) 4.6.3 Purposes of a trapdoor are to: • Allow access to the roof space from inside a house ✓ • Reach the geyser ✓ • Fit extra electrical wiring in the roof • Install cables in the roof • Gain access to storage space in the roof • Do plumbing in the roof • Do maintenance in the roof ANY TWO OF THE ABOVE (2) Copyright reserved Please turn over
Civil Technology: Woodworking 12 DBE/November 2025 NSC – Marking guidelines 4.7 2 2 2 4 3 6 6 2 5 5 SPANWYDTE = 3 000 MM 1 1 7 7 NO. ASSESSMENT CRITERIA MARK 1 Wall + correct internal span 2 USE A MASK TO MARK 2 Rafters 4 THIS QUESTION 3 Tie beam 1 4 King post 1 5 Overhang 2 6 Wall plates (Ignore hatching) 2 Application of scale: All correct =2 7 2 ONE or TWO incorrect =1 THREE and more incorrect = 0 TOTAL: 14 (14) [40] Copyright reserved Please turn over
Civil Technology: Woodworking 13 DBE/November 2025 NSC – Marking guidelines QUESTION 5: CENTERING, FORMWORK, SHORING AND GRAPHICS AS MEANS OF COMMUNICATION (SPECIFIC) 5.1 A – Head tree ✓ B – Soffit board ✓ C – Prop ✓ D – Brace/Strut ✓ E – Side ✓ F – Shutter board ✓ G – Kicker/Fixing plate ✓ H – Wedge ✓ (8) 5.2 To ensure that the formwork is held in its plumb position ✓ and to withstand any forces acting on a column or the props (stability). ✓ (2) 5.3 A – Vertical struts/Posts ✓ B – Braces/Diagonal struts ✓ C – Horizontal shores ✓ D – Inclined strut/Raking strut ✓ E – Needle ✓ (5) 5.4 Materials used to cover gaps between laggings: • Plywood ✓ • Hardboard/Masonite ✓ (2) Copyright reserved Please turn over
Civil Technology: Woodworking 14 DBE/November 2025 NSC – Marking guidelines 5.5 3 2 1 1 COLLAR-TIE ROOF TRUSS NO. ASSESSMENT CRITERIA MARK 1 Rafters 2 Collar beam (Higher than half of vertical rise 2 1 of the rafter) 3 Ridge beam 1 TOTAL: 4 2 1 1 COUPLE ROOF TRUSS NO. ASSESSMENT CRITERIA MARK 1 Rafters 2 2 Ridge beam 1 TOTAL: 3 (7) Copyright reserved Please turn over
Civil Technology: Woodworking 15 DBE/November 2025 NSC – Marking guidelines 5.6 3 2 2 4 2 1 THE HORIZONTAL AND DIAGONAL BRACE CAN BE PLACED ON THE LEFT OR RIGHT OF THE STRUT IN THE CENTRE NO. ASSESSMENT CRITERIA MARK 1 Tie 1 2 Struts 3 3 Diagonal brace (ONE) 1 4 Horizontal brace (ONE) 1 TOTAL: 6 (6) [30] Copyright reserved Please turn over
Civil Technology: Woodworking 16 DBE/November 2025 NSC – Marking guidelines QUESTION 6: SUSPENDED FLOORS, STAIRCASES, IRONMONGERY, DOORS AND JOINING (SPECIFIC) 6.1 6.1.1 G✓ (1) 6.1.2 C✓ (1) 6.1.3 F✓ (1) 6.1.4 E✓ (1) 6.1.5 H✓ (1) 6.1.6 B✓ (1) 6.2 6.2.1 Clout nails/Nails/Chipboard screws/Screws ✓ (1) 6.2.2 Hinges ✓ (1) 6.3 Methods used to fix a wall plate to a wall: • Using galvanised straps that are nailed to the wall plate. ✓ • Wall plates can be bolted to a wall. ✓ • Wall plates can be nailed to a wall. ANY TWO OF THE ABOVE (2) Copyright reserved Please turn over
Civil Technology: Woodworking 17 DBE/November 2025 NSC – Marking guidelines 6.4 4 2 1 3 3 3 3 4 4 HATCHING 5 NO. ASSESSMENT CRITERIA MARK 1 Muntin 1 2 Clearance (both sides) 1 3 Raised and fielded panels 4 4 Bottom rail 1 5 Hatching (All parts correct) 1 TOTAL: 8 (8) 6.5 A – Newel post ✓ B – Landing ✓ C – Riser ✓ D – Pitch line ✓ E – Tread ✓ F – Handrail ✓ (6) Copyright reserved Please turn over
Civil Technology: Woodworking 18 DBE/November 2025 NSC – Marking guidelines 6.6 4 2 1 3 2 2 3 2 1 1 3 OR NO. ASSESSMENT CRITERIA MARK 1 Rail 3 2 Double bare-faced tenons 4 3 Shoulder (top, middle and bottom) 3 4 Rebate 1 TOTAL: 11 (11) Copyright reserved Please turn over
Civil Technology: Woodworking 19 DBE/November 2025 NSC – Marking guidelines 6.7 5 FLOOR BOARDS 4 FLOOR JOIST 4 4 3 BEARER 2 ANT GUARD 1 4 DPC BRICK PIER PAD FOUNDATION CONCRETE SYMBOL NO. ASSESSMENT CRITERIA MARK 1 DPC 1 2 Ant guard 1 3 Bearer 1 4 Floor joist 1 5 Floor boards 1 TOTAL: 5 (5) [40] TOTAL: 200 Copyright reserved

Study this subject

More from Grade 12 Civil Technology

View all